新NATIONALSTANDARDWord文件下载.docx
《新NATIONALSTANDARDWord文件下载.docx》由会员分享,可在线阅读,更多相关《新NATIONALSTANDARDWord文件下载.docx(33页珍藏版)》请在冰豆网上搜索。
THEPEOPLE'
CODEFORDESIGNOFEXTINGUISHER
DISTRIBUTIONINBUILDINGS
GBJ140-90
ChiefEditorialDepartment:
MinistryofPubiicSecurity
oftheP.R.China
ApprovedDepartment:
MinistryofConstruction
DateofEnforcement:
August1,1991
NationalStandardofthePeople'
sRepublicofChina
CODEFORDESIGNOFEXTINGUISHER
DISTRIBUTIONINBUILDINGS
====================================================
GBJ140-90
ChiefFormulator:
TheMinistryofPublicSecurityofPRC
Approver:
TheMinistryofConstructionofPRC
EffectiveDate:
ChinaPlanningPublishingHouse
1991Beijing
NationalStandardof
thePeople'
sRepublicofChina
CODEFORDESIGNOF
EXTINGUISHERDISTRIBUTIONINBUILDINGS
FormulatedbytheMinistryofPublic
SecurityofPRC
PublishedbyChinaPlanningPublishingHouse
Preface
ThisbookistheEnglishtranslationofCodefordesignofextinguisherdistributioninbuildingsGBJ140-90.ItistheofficialtranslationoftheoriginalinChineseforgeneraluseasexaminedandapprovedbytheDepartmentofstandardsandNorms,MinistryofConstructionofthePeople'
sRepublicofChina.
IntheeventofanyinconsistencybetweentheChinese-languagetextoftheCodeandthepresentEnglish-languagetextoftheCode,theChinese-languagetextshallbetakenasruling.
DepartmentofStandardsandNorms,Ministryof
ConstuctionofthePeople'
cCOPYRIGHTDepartmentofStandardsandNorms,MinistryofConstruction,thePeople'
sRepublicofChina1997
Allrightsreserved.Nopartofthispublicationmaybereproduced,storedinaretrievalsystem,ortransmittedinanyformorbyanymeans,electronic,mechanical,photocopying,recording,orotherwise,withoutthepriorpermissionoftheMinistryofConstruction,thePeople'
NoticeontheIssueoftheNationalStandard
"
CodeforDesignofExtinguisherDisrtibutioninBuildings"
(90)JianBiaoNo.666
"
CodeforDesignofExtinguisherDistributioninBuildings"
formulatedbytheMinistryofPublicSecurityinco-operationwithrelevantdepartmentsinaccordancewiththerequirementsoftheNoticeJiZong(1986)No.2630offormerStatePlanningCommissionhasbeenexaminedjointlybyrelevantdepartments."
DesignCodeforDistributionofFireExtinguishersinBuildings"
GBJ140-90isherebyapprovedasanationalstandard,andshallcomeintoeffectonthedateofAugust1,1991.
TheMinistryofPublicSecurityisresponsibleforthemanagementoftheCode,ShanghaiFireResearchInstituteoftheMinistryofPublicSecurityisresponsiblefortheinterpretationindetail,andStandardQuotasResearchInstituteoftheMinistryofConstructionisresponsibleforarrangingthepublicationanddistribution.
December20,1990
TheMinistryofConstruction,P.R.C
NoteontheFormulationoftheCode
TheCodewasformulatedbytheCodeFormulationGroupjointlyestablishedbyShanghaiFireResearchInstituteoftheMinistryofPublicSecurityandrelevantdesigningorganizations,publicsecuritydepartmentsandproductionfactories,etc.inaccordancewiththerequirementsoftheNoticeJiZong(1986)No.2630offormerStatePlanningCommission.
DuringthecourseofformulationoftheCode,inaccordancewithrelevantpoliciesonnationalcapitalconstructionaswellasthefireprotectionprincipleof"
puttingpreventioninthefirstplaceandcombiningpreventionwithsuppression"
extensiveinvestigationsweremadeintothecurrentsituationofdistributionoffireextinguishersinindustrialandcivilbuildings,theexperienceofpracticeinrecentyearsinChinawassummedup,theesultsofextinguishingtestsforverifyingtheratingsofvariousfireextinguishers,includinghalogenatedhydrocarbon,drychemical,carbondioxideandfoamfireextinguishers,wereadopted,relevantstandardsandcodesoftheUnitedState,EnglandandAustralia,etc.wereusedforreference,andcommentsfromvariousdesigningor-
ganizations,researchinstitutes,collegesanduniversitiesandend-usersincertainprovinces,autonomousregionsandmunicipalitiesandthoseundercertainministriesandStatecommissionswerecollected.ThedraftoftheCodewasdiscusseandrevisedseveraltimes,andwasexaminedandfinalizedjointlybydepartmentsconcerned.
TheCodeconsistsofsixchaptersandsixappendices.Itsmaincontentincludes:
generalprovisions,typesofhazardsinfireextinguisherdistributionareasandratingsoffireextinguishers,selectionoffireextinguishers,distributionoffireextinguishers,locationandmountingofireextinguishers,anddesigncalculationofdistributionoffireextinguishers,etc.
SincetheCodeisformulatedforthefirsttime,itishopedthatvariousorganizationswill,inthecourseofimplementationoftheCode,seriouslysumuptheirexperienceinthelightofinformationanddata,andmakecommentsandsuggestionsontheCode.PleasesendyourcommentsandsuggestionstogetherwithyourinformationanddatabymailtoShanghaiFireResearchInstitute(address:
601ZhongshanRoadS.2,Shanghai,postalCode:
200032)forreferencewhentheCodeisrevised.
October1990
TheMinistryofPublicSecurity,P.R.C
Partialrevisionprovisions
PartialrevisionoftheNationalstandardsfor
engineeringconstruction
NoticeNo.10
Partsofthenationalstandard,"
Codefordesignofextinguisherdistributioninbuildings"
GBJ140-90,havebeenrevisedbyShanghaiFireResearchInstituteofMinistryofPublicSecurityofP.R.Chinaworkinginconjunctionwithotherrelatedorganizations.Thispartialrevisionhasbeenexaminedbytherelevantdeartments.Now,aprovethepartialrevisionprovisions,anditwillbeenforcementfromsep.1,1997.Provisionsintheunrevisedcodecorrespondingtothoseamendedintherevisedcodeareinvalid.Now,issuetheproclaimation.
MinistryofConstruction,People'
JUN.24,1997
Contents
ChapterIGeneralProvisions
ChapterIITypesofHazardsinFireExtinguisher
DistributionAreasandRatingsofFire
Extinguishers
ChapterIIISelectionofFire
ChapterIVDistributionofFire
ChapterVLocationandMountingofFire
Section1RequirementsforLocationandMounting
ofFire
Extinguishers
Section2TravelDistancestoFire
ChapterVIDesignCalculationofDistributionofFire
AppendixAExplanationTerms
AppendixBExamplesofTypesofHazardsinFire
ExtinguisherDistributionAreasin
IndustrialBuildings
AppendixCExamplesofTypesofHazardsinFire
CivilBuildings
AppendixDIncompatibleExtinguishing
Agents
AppendixEServiceTemperatureRangesofFire
AppendixFExplanationofWordsUsedinthe
Code
AppendixGExamplesofsiteswhereHalonExtinguishersis
unnecessarily
distributed
AppendixHExamplesofEquivalentSubstitutionofHalon
Extinguisher
AppendedNote
ChapterIGeneralProvisions
Article1.0.1Forthepurposeofreasonablydistributing
fireextinguishers,effectivelysuppressinginitialfiresinindustrialandcivilbuildings,minimizingfiredamageandprotectingthesafetyofpersonsandproperty,theCodeisherebyformulated.
Article1.0.2TheCodeappliestonew,extendedandrenovatedindustrialandcivilbuildingswherecombustiblesaremanufactured,usedorstored.TheCodedoesnotapplytofactorybuildings(warehouses)wheregunpowder,explosives,ammunition,primingsystemsandfireworksaremanufacturedandstored,andnine-and-less-storeyordinarydwellinghouses.
Article1.0.3Thetype,size,numberandlocationoffireextinguishersdistributedinabuildingshallbedeemedasthecontentofbuildingdesign,andshallbemarkedontheprojectdesigningdrawings.
Article1.0.4InadditiontotheprovisionsoftheCode,
thedesignofdistributionoffireextinguishersinabuildingshallalsomeettherequirementsofrelevantcurrentstandardsandcodesofChina.
ChapterIITypesofHazardsinFireExtinguisher
DistributionAreasandRatingsofFireExtinguishers
Article2.0.1Thetypesofhazardsinfireextinguisherdistributionareasinindustrialbuildingsshallbedeterminedaccordingtosuchfactorsasthefireharzardsofthegoodsmanufactured,usedandstored,theamountofcombustiblescontained,thespeedoffirespreadandthedegreeofdifficultyinfiresuppressionincaseoffire,etc.Therearethreetypesofhazards:
1)Severehazard:
Areasinwhichhighfirehazardsexist,
combustiblesarecontainedinlargeamounts,andfiremayspreadquicklyorisliabletocauseheavydamageincaseoffire;
2)Moderatehazard:
Areasinwhichrelativelyhighfire
azardsexist,combustiblesarecontainedinrelativelylargeamounts,andfiremayspreadrelativelyquicklyincaseoffire;
and
3)Lighthazard:
Areasinwhichrelativelylowfirehazardsexist,combustiblesarecontainedinrelativelysmallamounts,andfiremayspreadrelativelyslowlyincaseoffire.
Forexamplesoftypesofhazardsinfireextinguisherdis-tributionareasinindustrialbuildingsseeAppendixBoftheCode.
Article2.0.2Thetypesofhazardsinfireextinguisher
distributionareasincivilbuildingsshallb