告警目录
1.ALMcINH:
Alarminginhibited
2.LINEFEcPWD:
Automaticpowerdownactive(Farendcommand)
3.LINENEcPWD:
Automaticpowerdownactive(Nearendcommand)
4.AUTOcSWP:
Autoswitchtoprimary
5.AUTOcSWS:
Autoswitchtosecondary
6.BCLAN1cUPF:
BCLAN1failure
7.BCLAN2cUPF:
BCLAN2failure
8.SYScBOOT:
Bootinprocess
9.CPcRST:
CPresetinprogress
10.UNKNcCPF:
CP(unknowntype)failure
11.UNKNcCPR:
CP(unknowntype)removed
12.DCCcFLR:
DCCfailure
13.DCCcSTU:
DCCstartup
14.TIDcFLR:
Duplicatenodename
15.FORcSWP:
Forceswitchtoprimary
16.FORcSWS:
Forceswitchtosecondary
17.FUSPWRA1cFLR:
Fuse/Powerfailureshelf1
18.FUSPWRA2cFLR:
Fuse/Powerfailureshelf2
19.FUSPWRA1cFLR:
Fuse/Powerfailureshelf3
20.FUSPwRAB1cFLR:
Fuse/powerfailureAandBShelf1
21.FUSPwRAB2cFLR:
Fuse/powerfailureAandBShelf1
22.FUSPwRAB1cFLR:
Fuse/powerfailureAandBShelf3
23.FUSPwRB1cFLR:
Fuse/powerfailureBShelf1
24.FUSPwRB1cFLR:
Fuse/powerfailureBShelf2
25.FUSPwRB1cFLR:
Fuse/powerfailureBShelf3
26.OACODEScINC:
InconsistentOAitemcodes
27.OACODES1cINC:
InconsistentOAitemcodesinside1
28.OACODES2cINC:
InconsistentOAitemcodesinside2
29.PTELMcINH:
Inhibitalarms-paralleltelemetry
30.OACODEcMIS:
ItemcodeincompatiblewithOAModeprovisioning
31.ICHANcLOS:
Lossofinternalchannel
32.ITRIBcLOS:
Lossofinternaltributary
33.LSBBcLOS:
Lossoflowspeedbroadbandsignal
34.OPScPLOS:
LossofOPSPrimarysignal
35.OPScSLOS:
LossofOPSsecondarysignal
36.OCHANcLOS:
Lossofopticalchannel
37.MLQ2:
LossofQ2-communications
38.TRIBcLOS:
Lossoftributary
39.MANcSWP:
Manualswitchtoprimary
40.MANcSWS:
Manualswitchtosecondary
41.NMCONFcOVFL:
MaximumNMconfigurationexceeded
42.MDcIPXXX:
MDI#:
43.SYSMEMcUPF:
MEMfailure
44.DSNEcFLR:
MultipleDSNEsdefined
45.SYSMEMcNVM:
NVMcontenetsinvalid
46.OAcUPF:
OAfailure
47.OALANxUPF:
OALANfailure
48.OAcDIS:
OAoutputdisabled
49.OAcUPR:
OAremoved
50.OASTATEcMIS:
OAState-OAModemismatch
51.OASTATE1cMIS:
OAState-OAModemismatchinside1
52.OASTATE2cMIS:
OAState-OAModemismatchinside2
53.ODUcWMU:
ODUwarmupinprogress
54.OMSPAPDcCFL:
OMSP-APDconfigurationconflict
55.OMSPcCONF:
OMSPconfigurationfailure
56.OMDUcMIS:
OMU/ODUmismatchormissing
57.OPScEQF:
OPSfailure
58.OPScFCF:
OPSpowerconverterfailure
59.OPScEQR:
OPSremoved
60.OPScWMU:
OPSwarmupinprogress
61.OCRXPWRcTHR15:
Opticalchannelinputpowerthresholdcrossing15-min
62.OCRXPWRcTHR24:
Opticalchannelinputpowerthresholdcrossing24-hrs
63.OLRXPWRcTHR15:
Opticallineinputpowerthresholdcrossing15-min
64.OLRXPWRcTHR24:
Opticallineinputpowerthresholdcrossing24-hrs
65.OLINEcLOS:
Opticallinelossofsignal
66.OLINEcMIS:
Opticallinemisconnection
67.OLINEcRST:
Opticallinereetinprogress
68.OTRXPWRcTHR15:
Opticaltributaryinputpowerthresholdcrossing15-min
69.OTRXPWRcTHR24:
Opticaltributaryinputpowerthresholdcrossing24-hrs
70.OTTXPWRcTHR15:
Opticaltributarytransmitpowerthresholdcrossing15-min
71.OTTXPWRcTHR24:
Opticaltributarytransmitpowerthresholdcrossing24-hrs
72.OTCTLcEQF:
OTCTLfailure
73.OTCTLcEQR:
OTCTLremoved
74.OTPMcEQF:
OTPMfailure
75.OTPMcEQR:
OPTMremoved
76.OTPMcUNKN:
OTPMunknown
77.OTUcEQF:
OUTfailure
78.OTUcEQR:
OUTremoved
79.QOTUcEQF:
QOTUfailure
80.QOTUcEQR:
QOTUremoved
81.RSCVcTHR15:
RSCodeviolationsthresholdcrossing15-min
82.RSCVcTHR24:
RSCodeviolationsthresholdcrossing24-hrs
83.RSEScTHR15:
RSNear-enderroredsecondsthresholdcrossing15-min
84.RSEScTHR24:
RSNear-enderroredsecondsthresholdcrossing24-hrs
85.RSSEScTHR15:
RSNear-endseverelyESthresholdcrossing15-min
86.RSSEScTHR24:
RSNear-endseverelyESthresholdcrossing24-hrs
87.RScTIM:
RStraceidentifiermismatch
88.TLMcUPF:
Serialtelemetryport1failure
89.SFTWcDWN:
Softwaredownloadinprogress
90.SPODUcEQF:
SPODUfailure
91.SPODUcPCF:
SPODUpowerconverterfailure
92.SPODUcEQR:
SPODUremoved
93.SPODUcWMU:
SPODUwarmupinprogress
94.SPOMUcEQF:
SPOMUfailure
95.SPOMUcPCF:
SPOMUpowerconverterfailure
96.SPOMUcEQR:
SPOMUremoved
97.SPOMUcWMU:
SPOMUwarmupinprogress
98.SYSCTLcEQF:
STCfailure
99.STM1cLOF:
STM-1Lossofframealignment-servicefailed
100.STM1cLOS:
STM-1Lossofinputsignal-servicefailed
101.STM1cLOSLOF:
STM1lossodsignal/framealignment
102.MS1cEXC:
STM-1MSExcessivebiterrorrate
103.MS1cDEG:
STM-1MSModeratebiterrorrate
104.STM4cLOSLOF:
STM-4lossofsignal/framealigment
105.STM16cLOSLOF:
STM-16lossofsignal/framealigment
106.SUPCVcTHR15:
Supervisorychannelcodeviolationsthresholdcrossing15min
107.SUPCVcTHR24:
Supervisorychannelcodeviolationsthresholdcrossing24hrs
108.SUPEScTHR15:
Supervisorychannelerroredsecondsthresholdcrossing15min
109.SUPEScTHR24:
Supervisorychannelerroredsecondsthresholdcrossing24hrs
110.SUPLBCcTHR15:
Supervisorychannellaserbiascurrentthresholdcrossing15min
111.SUPLBCcTHR24:
Supervisorychannellaserbiascurrentthresholdcrossing24hrs
112.SUPRXPWRcTHR15:
Supervisorychannelopticalinputpowerthresholdcross15min
113.SUPRXPWRcTHR24:
Supervisorychannelopticalinputpowerthresholdcross24hrs
114.SUPSEScTHR15:
Supervisorychannelseverelyerroredsecondsthresholdcross15min
115.SUPSEScTHR24:
Supervisorychannelseverelyerroredsecondsthresholdcross24hrs
116.SUPUAScTHR15:
Supervisorychannelunavailablesecondsthresholdcross15min
117.SUPUAScTHR24:
Supervisorychannelunavailablesecondsthresholdcross24hrs
118.SUPcEXC:
Supervisoryexcessivebiterrorrate
119.SUPcLOSLOP:
Supervisorylossofsignal/framealignment
120.SUPcDEG:
Supervisorymoderatebiterrorrate
121.LCKcSW:
Switchlockout
122.SYSMEMcSWM:
SWversionmismatch
123.SYSMEMcUPR:
Systemmemoryremoved
124.DSNEcNRE:
TheDSNEisnotreachable
125.TLMcEQF:
TLMfailure
126.TLMcEQR:
TLMremoved
127.TOCcUPF:
TOCfailure
128.TOCcUPR:
TOCremoved
129.OTLBCcTHR15:
Tributarylaserbiascurrentthresholdcrossing15-min
130.OTLBCcTHR15:
Tributarylaserbiascurrentthresholdcrossing24-hrs
131.OTPMcWUP:
UnexpectedOTPMtype
132.WUPcUPF:
Wrongunit-servicefailed
告警描述
1.ALMcINH:
Alarminginhibited
告警描述:
中继段站告警被禁止
告警等级:
信息
告警类型:
传输
本地现象:
用户面板上信息指示灯亮,本站站告警关闭
告警原因:
网管系统关闭站告警功能
清除方法:
在网管上恢复站告警功能
注:
这是由用户发出的指令造成的告警,只有得到确认不需要该指令时
才能清除该指令
2.LINEFEcPWD:
Automaticpowerdownactive(Farendcommand)
告警描述:
因远端网元丢失输入信号而自动切断光放大器电源,防止光放大器
输出激光对维护人员眼睛造成伤害
告警等级:
信息
告警类型:
处理
本地现象:
用户面板上信息指示灯亮
告警原因:
网元收到远端失效指示信号(TLM-RDI),该指示信号的产生是因为下
游端相邻网元检测不到输入信号,可能存在光纤断路、接头断开或设备故障。
清除方法:
清除下游端故障
注:
故障清除以后,光放大器会自动接通电源并重新启动,在一秒种内
输出功率恢复正常
3.LINENEcPWD:
Automaticpowerdownactive(Nearendcommand)
告警描述:
因本地网元丢失输入信号而自动切断光放电源?
告警等级:
信息
告警类型:
处理
本地现象:
用户面板上信息指示灯亮,光放上的FAULT指示灯闪亮,上游
端检测到远端失效指示信号(TLM-RDI)
告警原因:
网元接收不到输入信号,可能存在光纤断路、接头不清洁、断
开或设备故障。
清除方法:
清洁接头、恢复光纤连接或检查光放,检查上游端光缆和设备
注:
故障清除以后,光放大器会自动接通电源并重新启动,在一秒种内
输出功率恢复正常
4.AUTOcSWP:
Autoswitchtoprimary
告警描述:
光保护倒换开关(OPS)自动倒换到主用线路
告警等级:
信息
告警类型:
处理
本地现象:
用户面板上信息指示灯亮
告警原因:
在备用线路上检测不到输入信号,系统倒换到主用线路
清除方法:
检查上游端设备
5.AUTOcSWS:
Autoswitchtosecondary
告警描述:
光保护倒换开关(OPS)自动倒换到备用线路
告警等级:
信息
告警类型:
处理
本地现象:
用户面板上信息指示灯亮
告警原因:
在主用线路上检测不到输入信号,系统倒换到备用线路
清除方法:
检查上游端设备
6.BCLAN1cUPF:
BCLAN1failure
告警描述:
控制总线1失效,控制总线在光波长转换控制器(OTCTL)和光波
长转换单元盘(OTU)之间传递控制信息
告警等级:
紧急
告警类型:
设备
本地现象:
用户面板上紧急指示灯亮,若故障是由以上单元盘引起,则单
元盘故障指示灯亮,系统倒换到另一控制总线上
告警原因:
某个单元盘将总线吊死
清除方法:
按以下顺序检查单元盘:
QuadOTU,OTU,OTCTL
注:
代替单元盘可能影响业务
7.BCLAN2cUPF:
BCLAN2failure
告警描述:
控制总线2失效,控制总线在光波长转换控制器(OTCTL)和光波
长转换单元盘(OTU)之间传递控制信息
告警等级:
紧急
告警类型:
设备
本地现象:
用户面板上紧急指示灯亮,若故障是由以上单元盘引起,则单
元盘故障指示灯亮,系统倒换到另一控制总线上
告警原因:
某个单元盘将总线吊死
清除方法:
按以下顺序检查单元盘:
QuadOTU,OTU,OTCTL
注:
代替单元盘可能影响业务
8.SYScBOOT:
Bootinprocess
告警描述:
用户命令重启动或系统自动重启动
告警等级:
紧急
告警类型:
处理
本地现象:
用户面板上紧急指示灯亮
告警原因:
用户发出重启动指令或系统加电启动
9.CPcRST:
CPresetinprogress
告警描述:
安装电路盘以后正在安装系统软件
告警等级:
信息
告警类型:
设备
本地现象:
用户面板上信息指示灯亮
告警原因:
软件正在下载
注:
SYSCTL和SYSMEM单元盘需要15分钟进行软件下载
OTCTL和TOHCTL单元盘需要10分钟进行软件下载
其它单元盘需要1分钟进行软件下载
10.UNKNcCPF:
CP(unknowntype)failure
告警描述:
?
槽道中安装了无效或错误的单元盘,软件不认识该盘
告警等级:
紧急
告警类型:
设备
本地现象:
用户面板上紧急指示灯亮,单元盘紧急指示灯亮
告警原因:
单元盘无效或单元盘安装错误
告警清除:
替换单元盘
11.UNKNcCPR:
CP(unknowntype)removed
告警描述:
槽道中移去了单元盘
告警等级:
紧急
告警类型:
设备
本地现象:
用户面板上紧急指示灯亮
告警原因:
移去了单元盘
告警清除:
插入单元盘
12.DCCcFLR:
DCCfailure
告警描述:
本地网元无法通过监控信号的DCC通道进行通信
告警等级:
延迟
告警类型:
处理
本地现象:
用户面板上延迟指示灯亮
告警原因:
开销控制器(TOHCTL)正在启动,开销控制器故障,上游设备失
效或输入监控信号的源头处硬件故障
告警清除:
等待开销控制器重启动,约10分钟,替换开销控制器,清除上
游设备故障,参考其他告警信息
13.DCCcSTU:
DCCstartup
告警描述:
DCC通道正在启动
告警等级:
紧急
告警类型:
处理
本地现象:
用户面板上紧急指示灯亮
告警原因:
DCC通道正在重启动,恢复和网管的联系
告警清除:
等待15分钟直到告警清除
注:
网元间相互作用可能会需要10-15分钟,和其他网元通信可能
导致DCC失效
14.TIDcFLR:
Duplicatenodename
告警描述:
节点名称在网络中不唯一
告警等级:
紧急
告警类型:
处理
本地现象:
用户面板上紧急指示灯亮
告警原因:
DSNE节点拒绝接收网元,因为另一网元和该网元同名并已注册
告警清除:
改变网元名称
15.FORcSWP:
Forceswitchtoprimary
告警描述:
强制OPS倒换到主用线路
告警等级:
信息
告警类型:
处理
本地现象:
用户面板上信息指示灯亮
告警原因:
OPS单元盘被强制倒换到主用线路
告警清除:
发出清除指令
注:
这是由用户发出的指令,只有得到确认不需要该指令时才能清
除该指令
16.FORcSWS:
Forceswitchtosecondary
告警描述:
强制OPS倒换到备用线路
告警等级:
信息
告警类型:
处理
本地现象:
用户面板上信息指示灯亮
告警原因:
OPS单元盘被强制倒换到备用线路
告警清除:
发出清除指令
注:
这是由用户发出的指令,只有得到确认不需要该指令时才能清
除该指令
17.FUSPWRA1cFLR:
Fuse/Powerfailureshelf1
告警描述:
检测到光波长转换子架1(OTU-1)保险丝熔断或电源失效
告警等级:
紧急
告警类型:
设备
本地现象:
如果用户面板不受保险丝和电源故障的影响,则用户面板紧急
告警指示灯亮
告警原因:
电源盒A电源失效或保险丝熔断,光波长转换子架1电源失效
或电源滤波电路板故障
告警清除:
替换光波长转换子架1的保险丝,检查电源线,替换滤波面板中
的滤波电路板
18.FUSPWRA2cFLR:
Fuse/Powerfailureshelf2
告警描述:
检测到光波长转换子架2(OTU-2)保险丝熔断或电源失效
告警等级:
紧急
告警类型:
设备
本地现象:
如果用户面板不受保险丝和电源故障的影响,则用户面板紧急
告警指示灯亮
告警原因:
电源盒A电源失效或保险丝熔断,光波长转换子架2电源失效
或电源滤波电路板故障
告警清除:
替换