80Galarm

 

告警目录

 

1.ALMcINH:

Alarminginhibited

2.LINEFEcPWD:

Automaticpowerdownactive(Farendcommand)

3.LINENEcPWD:

Automaticpowerdownactive(Nearendcommand)

4.AUTOcSWP:

Autoswitchtoprimary

5.AUTOcSWS:

Autoswitchtosecondary

6.BCLAN1cUPF:

BCLAN1failure

7.BCLAN2cUPF:

BCLAN2failure

8.SYScBOOT:

Bootinprocess

9.CPcRST:

CPresetinprogress

10.UNKNcCPF:

CP(unknowntype)failure

11.UNKNcCPR:

CP(unknowntype)removed

12.DCCcFLR:

DCCfailure

13.DCCcSTU:

DCCstartup

14.TIDcFLR:

Duplicatenodename

15.FORcSWP:

Forceswitchtoprimary

16.FORcSWS:

Forceswitchtosecondary

17.FUSPWRA1cFLR:

Fuse/Powerfailureshelf1

18.FUSPWRA2cFLR:

Fuse/Powerfailureshelf2

19.FUSPWRA1cFLR:

Fuse/Powerfailureshelf3

20.FUSPwRAB1cFLR:

Fuse/powerfailureAandBShelf1

21.FUSPwRAB2cFLR:

Fuse/powerfailureAandBShelf1

22.FUSPwRAB1cFLR:

Fuse/powerfailureAandBShelf3

23.FUSPwRB1cFLR:

Fuse/powerfailureBShelf1

24.FUSPwRB1cFLR:

Fuse/powerfailureBShelf2

25.FUSPwRB1cFLR:

Fuse/powerfailureBShelf3

26.OACODEScINC:

InconsistentOAitemcodes

27.OACODES1cINC:

InconsistentOAitemcodesinside1

28.OACODES2cINC:

InconsistentOAitemcodesinside2

29.PTELMcINH:

Inhibitalarms-paralleltelemetry

30.OACODEcMIS:

ItemcodeincompatiblewithOAModeprovisioning

31.ICHANcLOS:

Lossofinternalchannel

32.ITRIBcLOS:

Lossofinternaltributary

33.LSBBcLOS:

Lossoflowspeedbroadbandsignal

34.OPScPLOS:

LossofOPSPrimarysignal

35.OPScSLOS:

LossofOPSsecondarysignal

36.OCHANcLOS:

Lossofopticalchannel

37.MLQ2:

LossofQ2-communications

38.TRIBcLOS:

Lossoftributary

39.MANcSWP:

Manualswitchtoprimary

40.MANcSWS:

Manualswitchtosecondary

41.NMCONFcOVFL:

MaximumNMconfigurationexceeded

42.MDcIPXXX:

MDI#:

43.SYSMEMcUPF:

MEMfailure

44.DSNEcFLR:

MultipleDSNEsdefined

45.SYSMEMcNVM:

NVMcontenetsinvalid

46.OAcUPF:

OAfailure

47.OALANxUPF:

OALANfailure

48.OAcDIS:

OAoutputdisabled

49.OAcUPR:

OAremoved

50.OASTATEcMIS:

OAState-OAModemismatch

51.OASTATE1cMIS:

OAState-OAModemismatchinside1

52.OASTATE2cMIS:

OAState-OAModemismatchinside2

53.ODUcWMU:

ODUwarmupinprogress

54.OMSPAPDcCFL:

OMSP-APDconfigurationconflict

55.OMSPcCONF:

OMSPconfigurationfailure

56.OMDUcMIS:

OMU/ODUmismatchormissing

57.OPScEQF:

OPSfailure

58.OPScFCF:

OPSpowerconverterfailure

59.OPScEQR:

OPSremoved

60.OPScWMU:

OPSwarmupinprogress

61.OCRXPWRcTHR15:

Opticalchannelinputpowerthresholdcrossing15-min

62.OCRXPWRcTHR24:

Opticalchannelinputpowerthresholdcrossing24-hrs

63.OLRXPWRcTHR15:

Opticallineinputpowerthresholdcrossing15-min

64.OLRXPWRcTHR24:

Opticallineinputpowerthresholdcrossing24-hrs

65.OLINEcLOS:

Opticallinelossofsignal

66.OLINEcMIS:

Opticallinemisconnection

67.OLINEcRST:

Opticallinereetinprogress

68.OTRXPWRcTHR15:

Opticaltributaryinputpowerthresholdcrossing15-min

69.OTRXPWRcTHR24:

Opticaltributaryinputpowerthresholdcrossing24-hrs

70.OTTXPWRcTHR15:

Opticaltributarytransmitpowerthresholdcrossing15-min

71.OTTXPWRcTHR24:

Opticaltributarytransmitpowerthresholdcrossing24-hrs

72.OTCTLcEQF:

OTCTLfailure

73.OTCTLcEQR:

OTCTLremoved

74.OTPMcEQF:

OTPMfailure

75.OTPMcEQR:

OPTMremoved

76.OTPMcUNKN:

OTPMunknown

77.OTUcEQF:

OUTfailure

78.OTUcEQR:

OUTremoved

79.QOTUcEQF:

QOTUfailure

80.QOTUcEQR:

QOTUremoved

81.RSCVcTHR15:

RSCodeviolationsthresholdcrossing15-min

82.RSCVcTHR24:

RSCodeviolationsthresholdcrossing24-hrs

83.RSEScTHR15:

RSNear-enderroredsecondsthresholdcrossing15-min

84.RSEScTHR24:

RSNear-enderroredsecondsthresholdcrossing24-hrs

85.RSSEScTHR15:

RSNear-endseverelyESthresholdcrossing15-min

86.RSSEScTHR24:

RSNear-endseverelyESthresholdcrossing24-hrs

87.RScTIM:

RStraceidentifiermismatch

88.TLMcUPF:

Serialtelemetryport1failure

89.SFTWcDWN:

Softwaredownloadinprogress

90.SPODUcEQF:

SPODUfailure

91.SPODUcPCF:

SPODUpowerconverterfailure

92.SPODUcEQR:

SPODUremoved

93.SPODUcWMU:

SPODUwarmupinprogress

94.SPOMUcEQF:

SPOMUfailure

95.SPOMUcPCF:

SPOMUpowerconverterfailure

96.SPOMUcEQR:

SPOMUremoved

97.SPOMUcWMU:

SPOMUwarmupinprogress

98.SYSCTLcEQF:

STCfailure

99.STM1cLOF:

STM-1Lossofframealignment-servicefailed

100.STM1cLOS:

STM-1Lossofinputsignal-servicefailed

101.STM1cLOSLOF:

STM1lossodsignal/framealignment

102.MS1cEXC:

STM-1MSExcessivebiterrorrate

103.MS1cDEG:

STM-1MSModeratebiterrorrate

104.STM4cLOSLOF:

STM-4lossofsignal/framealigment

105.STM16cLOSLOF:

STM-16lossofsignal/framealigment

106.SUPCVcTHR15:

Supervisorychannelcodeviolationsthresholdcrossing15min

107.SUPCVcTHR24:

Supervisorychannelcodeviolationsthresholdcrossing24hrs

108.SUPEScTHR15:

Supervisorychannelerroredsecondsthresholdcrossing15min

109.SUPEScTHR24:

Supervisorychannelerroredsecondsthresholdcrossing24hrs

110.SUPLBCcTHR15:

Supervisorychannellaserbiascurrentthresholdcrossing15min

111.SUPLBCcTHR24:

Supervisorychannellaserbiascurrentthresholdcrossing24hrs

112.SUPRXPWRcTHR15:

Supervisorychannelopticalinputpowerthresholdcross15min

113.SUPRXPWRcTHR24:

Supervisorychannelopticalinputpowerthresholdcross24hrs

114.SUPSEScTHR15:

Supervisorychannelseverelyerroredsecondsthresholdcross15min

115.SUPSEScTHR24:

Supervisorychannelseverelyerroredsecondsthresholdcross24hrs

116.SUPUAScTHR15:

Supervisorychannelunavailablesecondsthresholdcross15min

117.SUPUAScTHR24:

Supervisorychannelunavailablesecondsthresholdcross24hrs

118.SUPcEXC:

Supervisoryexcessivebiterrorrate

119.SUPcLOSLOP:

Supervisorylossofsignal/framealignment

120.SUPcDEG:

Supervisorymoderatebiterrorrate

121.LCKcSW:

Switchlockout

122.SYSMEMcSWM:

SWversionmismatch

123.SYSMEMcUPR:

Systemmemoryremoved

124.DSNEcNRE:

TheDSNEisnotreachable

125.TLMcEQF:

TLMfailure

126.TLMcEQR:

TLMremoved

127.TOCcUPF:

TOCfailure

128.TOCcUPR:

TOCremoved

129.OTLBCcTHR15:

Tributarylaserbiascurrentthresholdcrossing15-min

130.OTLBCcTHR15:

Tributarylaserbiascurrentthresholdcrossing24-hrs

131.OTPMcWUP:

UnexpectedOTPMtype

132.WUPcUPF:

Wrongunit-servicefailed

 

告警描述

 

1.ALMcINH:

Alarminginhibited

告警描述:

中继段站告警被禁止

告警等级:

信息

告警类型:

传输

本地现象:

用户面板上信息指示灯亮,本站站告警关闭

告警原因:

网管系统关闭站告警功能

清除方法:

在网管上恢复站告警功能

注:

这是由用户发出的指令造成的告警,只有得到确认不需要该指令时

才能清除该指令

 

2.LINEFEcPWD:

Automaticpowerdownactive(Farendcommand)

告警描述:

因远端网元丢失输入信号而自动切断光放大器电源,防止光放大器

输出激光对维护人员眼睛造成伤害

告警等级:

信息

告警类型:

处理

本地现象:

用户面板上信息指示灯亮

告警原因:

网元收到远端失效指示信号(TLM-RDI),该指示信号的产生是因为下

游端相邻网元检测不到输入信号,可能存在光纤断路、接头断开或设备故障。

清除方法:

清除下游端故障

注:

故障清除以后,光放大器会自动接通电源并重新启动,在一秒种内

输出功率恢复正常

 

3.LINENEcPWD:

Automaticpowerdownactive(Nearendcommand)

告警描述:

因本地网元丢失输入信号而自动切断光放电源?

告警等级:

信息

告警类型:

处理

本地现象:

用户面板上信息指示灯亮,光放上的FAULT指示灯闪亮,上游

端检测到远端失效指示信号(TLM-RDI)

告警原因:

网元接收不到输入信号,可能存在光纤断路、接头不清洁、断

开或设备故障。

清除方法:

清洁接头、恢复光纤连接或检查光放,检查上游端光缆和设备

注:

故障清除以后,光放大器会自动接通电源并重新启动,在一秒种内

输出功率恢复正常

 

4.AUTOcSWP:

Autoswitchtoprimary

告警描述:

光保护倒换开关(OPS)自动倒换到主用线路

告警等级:

信息

告警类型:

处理

本地现象:

用户面板上信息指示灯亮

告警原因:

在备用线路上检测不到输入信号,系统倒换到主用线路

清除方法:

检查上游端设备

 

5.AUTOcSWS:

Autoswitchtosecondary

告警描述:

光保护倒换开关(OPS)自动倒换到备用线路

告警等级:

信息

告警类型:

处理

本地现象:

用户面板上信息指示灯亮

告警原因:

在主用线路上检测不到输入信号,系统倒换到备用线路

清除方法:

检查上游端设备

 

6.BCLAN1cUPF:

BCLAN1failure

告警描述:

控制总线1失效,控制总线在光波长转换控制器(OTCTL)和光波

长转换单元盘(OTU)之间传递控制信息

告警等级:

紧急

告警类型:

设备

本地现象:

用户面板上紧急指示灯亮,若故障是由以上单元盘引起,则单

元盘故障指示灯亮,系统倒换到另一控制总线上

告警原因:

某个单元盘将总线吊死

清除方法:

按以下顺序检查单元盘:

QuadOTU,OTU,OTCTL

注:

代替单元盘可能影响业务

 

7.BCLAN2cUPF:

BCLAN2failure

告警描述:

控制总线2失效,控制总线在光波长转换控制器(OTCTL)和光波

长转换单元盘(OTU)之间传递控制信息

告警等级:

紧急

告警类型:

设备

本地现象:

用户面板上紧急指示灯亮,若故障是由以上单元盘引起,则单

元盘故障指示灯亮,系统倒换到另一控制总线上

告警原因:

某个单元盘将总线吊死

清除方法:

按以下顺序检查单元盘:

QuadOTU,OTU,OTCTL

注:

代替单元盘可能影响业务

 

8.SYScBOOT:

Bootinprocess

告警描述:

用户命令重启动或系统自动重启动

告警等级:

紧急

告警类型:

处理

本地现象:

用户面板上紧急指示灯亮

告警原因:

用户发出重启动指令或系统加电启动

 

9.CPcRST:

CPresetinprogress

告警描述:

安装电路盘以后正在安装系统软件

告警等级:

信息

告警类型:

设备

本地现象:

用户面板上信息指示灯亮

告警原因:

软件正在下载

注:

SYSCTL和SYSMEM单元盘需要15分钟进行软件下载

OTCTL和TOHCTL单元盘需要10分钟进行软件下载

其它单元盘需要1分钟进行软件下载

 

10.UNKNcCPF:

CP(unknowntype)failure

告警描述:

?

槽道中安装了无效或错误的单元盘,软件不认识该盘

告警等级:

紧急

告警类型:

设备

本地现象:

用户面板上紧急指示灯亮,单元盘紧急指示灯亮

告警原因:

单元盘无效或单元盘安装错误

告警清除:

替换单元盘

 

11.UNKNcCPR:

CP(unknowntype)removed

告警描述:

槽道中移去了单元盘

告警等级:

紧急

告警类型:

设备

本地现象:

用户面板上紧急指示灯亮

告警原因:

移去了单元盘

告警清除:

插入单元盘

 

12.DCCcFLR:

DCCfailure

告警描述:

本地网元无法通过监控信号的DCC通道进行通信

告警等级:

延迟

告警类型:

处理

本地现象:

用户面板上延迟指示灯亮

告警原因:

开销控制器(TOHCTL)正在启动,开销控制器故障,上游设备失

效或输入监控信号的源头处硬件故障

告警清除:

等待开销控制器重启动,约10分钟,替换开销控制器,清除上

游设备故障,参考其他告警信息

 

13.DCCcSTU:

DCCstartup

告警描述:

DCC通道正在启动

告警等级:

紧急

告警类型:

处理

本地现象:

用户面板上紧急指示灯亮

告警原因:

DCC通道正在重启动,恢复和网管的联系

告警清除:

等待15分钟直到告警清除

注:

网元间相互作用可能会需要10-15分钟,和其他网元通信可能

导致DCC失效

 

14.TIDcFLR:

Duplicatenodename

告警描述:

节点名称在网络中不唯一

告警等级:

紧急

告警类型:

处理

本地现象:

用户面板上紧急指示灯亮

告警原因:

DSNE节点拒绝接收网元,因为另一网元和该网元同名并已注册

告警清除:

改变网元名称

 

15.FORcSWP:

Forceswitchtoprimary

告警描述:

强制OPS倒换到主用线路

告警等级:

信息

告警类型:

处理

本地现象:

用户面板上信息指示灯亮

告警原因:

OPS单元盘被强制倒换到主用线路

告警清除:

发出清除指令

注:

这是由用户发出的指令,只有得到确认不需要该指令时才能清

除该指令

 

16.FORcSWS:

Forceswitchtosecondary

告警描述:

强制OPS倒换到备用线路

告警等级:

信息

告警类型:

处理

本地现象:

用户面板上信息指示灯亮

告警原因:

OPS单元盘被强制倒换到备用线路

告警清除:

发出清除指令

注:

这是由用户发出的指令,只有得到确认不需要该指令时才能清

除该指令

 

17.FUSPWRA1cFLR:

Fuse/Powerfailureshelf1

告警描述:

检测到光波长转换子架1(OTU-1)保险丝熔断或电源失效

告警等级:

紧急

告警类型:

设备

本地现象:

如果用户面板不受保险丝和电源故障的影响,则用户面板紧急

告警指示灯亮

告警原因:

电源盒A电源失效或保险丝熔断,光波长转换子架1电源失效

或电源滤波电路板故障

告警清除:

替换光波长转换子架1的保险丝,检查电源线,替换滤波面板中

的滤波电路板

 

18.FUSPWRA2cFLR:

Fuse/Powerfailureshelf2

告警描述:

检测到光波长转换子架2(OTU-2)保险丝熔断或电源失效

告警等级:

紧急

告警类型:

设备

本地现象:

如果用户面板不受保险丝和电源故障的影响,则用户面板紧急

告警指示灯亮

告警原因:

电源盒A电源失效或保险丝熔断,光波长转换子架2电源失效

或电源滤波电路板故障

告警清除:

替换