1、80G alarm 告 警 目 录1. ALMcINH:Alarming inhibited2. LINEFEcPWD:Automatic power down active(Far end command)3. LINENEcPWD:Automatic power down active(Near end command)4. AUTOcSWP:Auto switch to primary5. AUTOcSWS:Auto switch to secondary6. BCLAN1cUPF:BC LAN 1 failure7. BCLAN2cUPF:BC LAN 2 failure8. SYSc
2、BOOT:Boot in process9. CPcRST:CP reset in progress10. UNKNcCPF:CP(unknown type) failure11. UNKNcCPR:CP(unknown type) removed12. DCCcFLR:DCC failure13. DCCcSTU:DCC startup14. TIDcFLR:Duplicate node name15. FORcSWP:Force switch to primary16. FORcSWS:Force switch to secondary17. FUSPWRA1cFLR:Fuse/Power
3、 failure shelf 118. FUSPWRA2cFLR:Fuse/Power failure shelf 219. FUSPWRA1cFLR:Fuse/Power failure shelf 320. FUSPwRAB1cFLR:Fuse/power failure A and B Shelf 121. FUSPwRAB2cFLR:Fuse/power failure A and B Shelf 122. FUSPwRAB1cFLR:Fuse/power failure A and B Shelf 323. FUSPwRB1cFLR:Fuse/power failure B Shel
4、f 124. FUSPwRB1cFLR:Fuse/power failure B Shelf 225. FUSPwRB1cFLR:Fuse/power failure B Shelf 326. OACODEScINC:Inconsistent OA item codes27. OACODES1cINC:Inconsistent OA item codes in side 128. OACODES2cINC:Inconsistent OA item codes in side 229. PTELMcINH:Inhibit alarms-parallel telemetry30. OACODEcM
5、IS:Item code incompatible with OA Mode provisioning31. ICHANcLOS:Loss of internal channel32. ITRIBcLOS:Loss of internal tributary33. LSBBcLOS: Loss of low speed broadband signal34. OPScPLOS: Loss of OPS Primary signal35. OPScSLOS: Loss of OPS secondary signal36. OCHANcLOS: Loss of optical channel37.
6、 MLQ2: Loss of Q2-communications38. TRIBcLOS: Loss of tributary39. MANcSWP: Manual switch to primary40. MANcSWS: Manual switch to secondary41. NMCONFcOVFL: Maximum NM configuration exceeded42. MDcIPXXX: MDI#:43. SYSMEMcUPF: MEM failure44. DSNEcFLR: Multiple DSNEs defined45. SYSMEMcNVM: NVM contenets
7、 invalid46. OAcUPF: OA failure47. OALANxUPF: OA LAN failure48. OAcDIS: OA output disabled49. OAcUPR: OA removed50. OASTATEcMIS: OA State- OA Mode mismatch51. OASTATE1cMIS: OA State- OA Mode mismatch in side 152. OASTATE2cMIS: OA State- OA Mode mismatch in side 253. ODUcWMU: ODU warmup in progress54.
8、 OMSPAPDcCFL: OMSP-APD configuration conflict55. OMSPcCONF: OMSP configuration failure56. OMDUcMIS: OMU/ODU mismatch or missing57. OPScEQF: OPS failure58. OPScFCF: OPS power converter failure59. OPScEQR: OPS removed60. OPScWMU: OPS warmup in progress61. OCRXPWRcTHR15: Optical channel input power thr
9、eshold crossing 15-min62. OCRXPWRcTHR24: Optical channel input power threshold crossing 24-hrs63. OLRXPWRcTHR15: Optical line input power threshold crossing 15-min64. OLRXPWRcTHR24: Optical line input power threshold crossing 24-hrs65. OLINEcLOS: Optical line loss of signal66. OLINEcMIS: Optical lin
10、e misconnection67. OLINEcRST: Optical line reet in progress68. OTRXPWRcTHR15: Optical tributary input power threshold crossing 15-min69. OTRXPWRcTHR24: Optical tributary input power threshold crossing 24-hrs70. OTTXPWRcTHR15: Optical tributary transmit power threshold crossing 15-min71. OTTXPWRcTHR2
11、4: Optical tributary transmit power threshold crossing 24-hrs72. OTCTLcEQF: OTCTL failure73. OTCTLcEQR: OTCTL removed74. OTPMcEQF: OTPM failure75. OTPMcEQR: OPTM removed76. OTPMcUNKN: OTPM unknown77. OTUcEQF: OUT failure78. OTUcEQR: OUT removed79. QOTUcEQF: QOTU failure80. QOTUcEQR: QOTU removed81.
12、RSCVcTHR15: RS Code violations threshold crossing 15-min82. RSCVcTHR24: RS Code violations threshold crossing 24-hrs83. RSEScTHR15: RS Near-end errored seconds threshold crossing 15-min84. RSEScTHR24: RS Near-end errored seconds threshold crossing 24-hrs85. RSSEScTHR15: RS Near-end severely ES thres
13、hold crossing 15-min86. RSSEScTHR24: RS Near-end severely ES threshold crossing 24-hrs87. RScTIM : RS trace identifier mismatch88. TLMcUPF: Serial telemetry port1 failure89. SFTWcDWN: Software download in progress90. SPODUcEQF: SPODU failure91. SPODUcPCF: SPODU power converter failure92. SPODUcEQR:
14、SPODU removed93. SPODUcWMU: SPODU warmup in progress94. SPOMUcEQF: SPOMU failure95. SPOMUcPCF: SPOMU power converter failure96. SPOMUcEQR: SPOMU removed97. SPOMUcWMU: SPOMU warmup in progress98. SYSCTLcEQF: STC failure99. STM1cLOF: STM-1 Loss of frame alignment-service failed100. STM1cLOS: STM-1 Los
15、s of input signal-service failed101. STM1cLOSLOF: STM1 loss od signal/frame alignment102. MS1cEXC: STM-1 MS Excessive bit error rate103. MS1cDEG: STM-1 MS Moderate bit error rate104. STM4cLOSLOF: STM-4 loss of signal/frame aligment105. STM16cLOSLOF: STM-16 loss of signal/frame aligment106. SUPCVcTHR
16、15: Supervisory channel code violations threshold crossing 15min107. SUPCVcTHR24: Supervisory channel code violations threshold crossing 24hrs108. SUPEScTHR15: Supervisory channel errored seconds threshold crossing 15min109. SUPEScTHR24: Supervisory channel errored seconds threshold crossing 24hrs11
17、0. SUPLBCcTHR15: Supervisory channel laser bias current threshold crossing 15min111. SUPLBCcTHR24: Supervisory channel laser bias current threshold crossing 24hrs112. SUPRXPWRcTHR15: Supervisory channel optical input power threshold cross 15min113. SUPRXPWRcTHR24: Supervisory channel optical input p
18、ower threshold cross 24hrs114. SUPSEScTHR15: Supervisory channel severely errored seconds threshold cross15min115. SUPSEScTHR24: Supervisory channel severely errored seconds threshold cross 24hrs116. SUPUAScTHR15: Supervisory channel unavailable seconds threshold cross 15min117. SUPUAScTHR24: Superv
19、isory channel unavailable seconds threshold cross 24hrs118. SUPcEXC: Supervisory excessive bit error rate119. SUPcLOSLOP: Supervisory loss of signal/frame alignment120. SUPcDEG: Supervisory moderate bit error rate121. LCKcSW: Switch lockout122. SYSMEMcSWM: SW version mismatch123. SYSMEMcUPR: System
20、memory removed124. DSNEcNRE: The DSNE is not reachable125. TLMcEQF: TLM failure126. TLMcEQR: TLM removed127. TOCcUPF: TOC failure128. TOCcUPR: TOC removed129. OTLBCcTHR15: Tributary laser bias current threshold crossing 15-min130. OTLBCcTHR15: Tributary laser bias current threshold crossing 24-hrs13
21、1. OTPMcWUP: Unexpected OTPM type132. WUPcUPF: Wrong unit-service failed 告 警 描 述1. ALMcINH:Alarming inhibited 告警描述: 中继段站告警被禁止 告警等级: 信息 告警类型: 传输 本地现象: 用户面板上信息指示灯亮,本站站告警关闭 告警原因: 网管系统关闭站告警功能 清除方法: 在网管上恢复站告警功能 注: 这是由用户发出的指令造成的告警,只有得到确认不需要该指令时才能清除该指令2. LINEFEcPWD:Automatic power down active(Far end comma
22、nd) 告警描述: 因远端网元丢失输入信号而自动切断光放大器电源,防止光放大器输出激光对维护人员眼睛造成伤害 告警等级: 信息 告警类型: 处理 本地现象: 用户面板上信息指示灯亮 告警原因: 网元收到远端失效指示信号(TLM-RDI),该指示信号的产生是因为下游端相邻网元检测不到输入信号,可能存在光纤断路、接头断开或 设备故障。 清除方法: 清除下游端故障 注: 故障清除以后,光放大器会自动接通电源并重新启动,在一秒种内输出功率恢复正常3. LINENEcPWD:Automatic power down active(Near end command) 告警描述: 因本地网元丢失输入信号而自
23、动切断光放电源 ? 告警等级: 信息 告警类型: 处理 本地现象: 用户面板上信息指示灯亮,光放上的FAULT指示灯闪亮,上游端检测到远端失效指示信号(TLM-RDI) 告警原因: 网元接收不到输入信号,可能存在光纤断路、接头不清洁、断开或设备故障。 清除方法: 清洁接头、恢复光纤连接或检查光放,检查上游端光缆和设备注: 故障清除以后,光放大器会自动接通电源并重新启动,在一秒种内输出功率恢复正常4. AUTOcSWP:Auto switch to primary 告警描述: 光保护倒换开关(OPS)自动倒换到主用线路 告警等级: 信息 告警类型: 处理 本地现象: 用户面板上信息指示灯亮告警原
24、因: 在备用线路上检测不到输入信号,系统倒换到主用线路 清除方法: 检查上游端设备5. AUTOcSWS:Auto switch to secondary 告警描述: 光保护倒换开关(OPS)自动倒换到备用线路 告警等级: 信息 告警类型: 处理 本地现象: 用户面板上信息指示灯亮告警原因: 在主用线路上检测不到输入信号,系统倒换到备用线路 清除方法: 检查上游端设备6. BCLAN1cUPF:BC LAN 1 failure 告警描述: 控制总线1失效,控制总线在光波长转换控制器(OTCTL)和光波长转换单元盘(OTU)之间传递控制信息 告警等级: 紧急 告警类型: 设备 本地现象: 用户面
25、板上紧急指示灯亮,若故障是由以上单元盘引起,则单元盘故障指示灯亮,系统倒换到另一控制总线上告警原因: 某个单元盘将总线吊死 清除方法: 按以下顺序检查单元盘:Quad OTU,OTU,OTCTL 注: 代替单元盘可能影响业务7. BCLAN2cUPF:BC LAN 2 failure 告警描述: 控制总线2失效,控制总线在光波长转换控制器(OTCTL)和光波长转换单元盘(OTU)之间传递控制信息 告警等级: 紧急 告警类型: 设备 本地现象: 用户面板上紧急指示灯亮,若故障是由以上单元盘引起,则单元盘故障指示灯亮,系统倒换到另一控制总线上告警原因: 某个单元盘将总线吊死 清除方法: 按以下顺序
26、检查单元盘:Quad OTU,OTU,OTCTL 注: 代替单元盘可能影响业务8. SYScBOOT:Boot in process 告警描述: 用户命令重启动或系统自动重启动 告警等级: 紧急 告警类型: 处理 本地现象: 用户面板上紧急指示灯亮 告警原因: 用户发出重启动指令或系统加电启动9. CPcRST:CP reset in progress 告警描述: 安装电路盘以后正在安装系统软件 告警等级: 信息 告警类型: 设备 本地现象: 用户面板上信息指示灯亮 告警原因: 软件正在下载 注: SYSCTL和SYSMEM单元盘需要15分钟进行软件下载 OTCTL和TOHCTL单元盘需要10
27、分钟进行软件下载 其它单元盘需要1分钟进行软件下载10. UNKNcCPF:CP(unknown type) failure 告警描述:?槽道中安装了无效或错误的单元盘,软件不认识该盘 告警等级: 紧急 告警类型: 设备 本地现象: 用户面板上紧急指示灯亮,单元盘紧急指示灯亮 告警原因: 单元盘无效或单元盘安装错误 告警清除: 替换单元盘11. UNKNcCPR:CP(unknown type) removed 告警描述: 槽道中移去了单元盘 告警等级: 紧急 告警类型: 设备 本地现象: 用户面板上紧急指示灯亮 告警原因: 移去了单元盘 告警清除: 插入单元盘12. DCCcFLR:DCC
28、failure 告警描述: 本地网元无法通过监控信号的DCC通道进行通信 告警等级: 延迟 告警类型: 处理 本地现象: 用户面板上延迟指示灯亮 告警原因: 开销控制器(TOHCTL)正在启动,开销控制器故障,上游设备失效或输入监控信号的源头处硬件故障 告警清除: 等待开销控制器重启动,约10分钟,替换开销控制器,清除上游设备故障,参考其他告警信息13. DCCcSTU:DCC startup 告警描述: DCC通道正在启动 告警等级: 紧急 告警类型: 处理 本地现象: 用户面板上紧急指示灯亮 告警原因: DCC通道正在重启动,恢复和网管的联系 告警清除: 等待15分钟直到告警清除 注: 网
29、元间相互作用可能会需要1015分钟,和其他网元通信可能导致DCC失效14. TIDcFLR:Duplicate node name 告警描述: 节点名称在网络中不唯一 告警等级: 紧急 告警类型: 处理 本地现象: 用户面板上紧急指示灯亮 告警原因: DSNE节点拒绝接收网元,因为另一网元和该网元同名并已注册 告警清除: 改变网元名称15. FORcSWP:Force switch to primary 告警描述: 强制OPS倒换到主用线路 告警等级: 信息 告警类型: 处理 本地现象: 用户面板上信息指示灯亮 告警原因: OPS单元盘被强制倒换到主用线路 告警清除: 发出清除指令 注: 这是
30、由用户发出的指令,只有得到确认不需要该指令时才能清除该指令16. FORcSWS:Force switch to secondary 告警描述: 强制OPS倒换到备用线路 告警等级: 信息 告警类型: 处理 本地现象: 用户面板上信息指示灯亮 告警原因: OPS单元盘被强制倒换到备用线路 告警清除: 发出清除指令 注: 这是由用户发出的指令,只有得到确认不需要该指令时才能清除该指令17. FUSPWRA1cFLR:Fuse/Power failure shelf 1 告警描述: 检测到光波长转换子架1(OTU-1)保险丝熔断或电源失效 告警等级: 紧急 告警类型: 设备 本地现象: 如果用户面
31、板不受保险丝和电源故障的影响,则用户面板紧急告警指示灯亮 告警原因: 电源盒 A电源失效或保险丝熔断,光波长转换子架 1电源失效或电源滤波电路板故障 告警清除: 替换光波长转换子架1的保险丝,检查电源线,替换滤波面板中的滤波电路板18. FUSPWRA2cFLR:Fuse/Power failure shelf 2 告警描述: 检测到光波长转换子架2(OTU-2)保险丝熔断或电源失效 告警等级: 紧急 告警类型: 设备 本地现象: 如果用户面板不受保险丝和电源故障的影响,则用户面板紧急告警指示灯亮 告警原因: 电源盒 A电源失效或保险丝熔断,光波长转换子架 2电源失效或电源滤波电路板故障 告警清除: 替换
copyright@ 2008-2022 冰豆网网站版权所有