电气英文自我评价范文.docx
《电气英文自我评价范文.docx》由会员分享,可在线阅读,更多相关《电气英文自我评价范文.docx(9页珍藏版)》请在冰豆网上搜索。
![电气英文自我评价范文.docx](https://file1.bdocx.com/fileroot1/2023-1/6/0919b184-3a25-4758-b1fe-0b38a3e5a493/0919b184-3a25-4758-b1fe-0b38a3e5a4931.gif)
电气英文自我评价范文
电气英文自我评价范文
电气英文自我评价范文篇一
Mynameis***,engagedinelectricalequipmentrepairworkhasbeen5years.Since*********yearsto******company,hasbeenworkingformorethantwoyears.Fromenteringthecompanyhasbeenengagedinsubstationoperationandmaintenanceandmanagement.Hasparticipatedinandorganizedahigh-pressuremeasurementandrelayprotectionsettingandcalibration;reactivepowercompensationandvoltagesetting;DCscreeninspectionandmaintenance;substationsecondarycircuitfaultandprocessing;high-voltagecabinetfailureandtreatment;high-voltagecableheadProductionandprocessing;substationinthespringandautumnalloverhaulandmaintenance;outdoorhighvoltageoverheadlinefaulthandlingandmaintenance.Ialwaysassiduouslywithhigh-voltagetechnologytoimprovetheoperatingrateofthecombination,andactivelystudytheprinciplesofhigh-voltageequipmentandmaintenanceexperience,andinsistonconstantlyimprovetheirtheoreticalandpracticalskillstosolvethesubstationrunningalotTechnicalproblems,inordertoimprovethepowertransmissionandtransmissionequipmentoperatingrateandlaidagoodfoundation.Substationisthepowersysteminthepowerofthevoltageandcurrenttransformation,concentrationanddistributionoftheplace.Inordertoensurethequalityofelectricalenergyandthesafetyoftheequipment,voltageregulation,powerflowandvoltagedistribution,distributionofpower,currentandpowerineachnodeandbranchofthepowersystemandcontroloftransmissionanddistributionlinesandProtectionofmajorelectricalequipment.Nowsubstationoverthepasttwoyearshaveexperiencedtheworksummarizedasfollows:
1,vacuumcircuitbreakersinthedailyoperationofthefaulttypesandtreatment.
November8,2018duetopowercompanylinefaultonmycompanylargepoweroutagefor3hours.Afterreceivingthenotice,wepressthepowersubstationregularpoweroutageproceduresforpoweroutages.Whenthepowercompanytodealwithfailureaftertransmission,accordingtopowertransmissionstep.Thenfoundthe35KVmaintransformervacuumcircuitbreakerrefusedtoclose,thisismycompanyhasjustputintooperationfortwomonthsthefirsttimethesubstationproblems,ourcompanysubstation35KVhighvoltagecabinetvacuumcircuitbreakerisappliedChintZN85-40.5circuitbreakers.Intheexperimentalstatefoundafterclosingthecircuitbreakercommand,closingelectromagnetaction,thecoreplungerwillclosethepawltopopen,closingthespringreleaseenergy,drivingthecircuitbreakerclosing,butthecircuitbreakerinterruptercannotbetogetherbrake.Afteranalysis,indicatingthatmechanicalfailurehasbeenexcluded,indicatingthatthesecondarylinefault,foundinthesecondaryauxiliaryplughasaneedleandcontrolwiredesoldering,vacuumbreakertodealwithafterclosing,faultproblemsolving.Vacuumcircuitbreakersinthedailyworkofthemostpronetofailuretobesummedup:
1.Positiveaircircuitbreakerrefusedtosub(gate)
2.Vacuumcircuitbreakerbodyenergystorage,energystoragemotorstop3.Vacuuminterrupterinterruptercannotbedisconnected2,thecurrenttransformersecondaryopenanddealwith
****Theendofthemonth,thepowercompanycameinFebruaryoftheelectricitydetails,withmycompanysubstationmeasuredbytheamountofdifference20182KW.h.Iledthetechnicalstafftoconductacomprehensiveinspectionofhigh-pressuremeasurement,duetolimitedconditions,failedtofindfaultproblems.Thecompanyinvitedthepowercompanymeteringandtestingcentersubstationsecondarycircuittest.Thecurrenttransformer,voltagetransformer,secondaryvoltagedropandsecondaryload,electricenergymeterof35KVand10KVeachswitchcabinetaretested.Inthepowercompanyequipmenttestingfound35KVhighback-upprotectionoftheterminalhasanindirectopenphenomenon.Afterprocessing,inthespecifiedtimewiththepowercompanymeteringcenter,theproblemhasbeenresolved.CurrenttransformerCTprimarywindingnumberofturnsissmall,theuseofawindinginseriesinthemeasuredline,thesecondarywindingturns,andmeasuringinstrumentsandrelaysandothercurrentcoilinseries,measuringinstrumentsandrelaysandothercurrentcoilimpedanceisverysmall,SothenormaloperationofCTisclosetoshort-circuitstate.CTsecondarycurrentsizedeterminedbytheprimarycurrent,secondarycurrentgeneratedbythemagneticpotential,istobalancethecurrentmagneticpotential.Ifthesecondaryopencircuit,theimpedanceisinfinite,thesecondarycurrentisequaltozero,themagneticpotentialisequaltozero,cannotbalancethecurrentgeneratedbyamagneticpotential,thenacurrentwillactontheexcitation,thecoreserioussaturation.Magneticsaturationincreasestheironloss,CTfever,CTcoilinsulationwillbeburnedbyoverheating.Butalsointhecoretoproduceremanence,increasingthetransformererror.Themostseriousisduetothemagneticsaturation,alternatingsinewaveintoatrapezoidalwave,therapidchangesinfluxmoment,thesecondarycoilwillinduceahighvoltage,thepeakuptoseveralthousandvolts,sohighOfthevoltageonthesecondarycoilandthesecondarycircuit,thepersonandequipmentareaseriousthreat.
3,tocompletethegoodleadershipoftheotherbasicandtemporaryworkassigned.
Overthepastyear,Iamlearningandworkinginthegradualgrowthandmaturity,butIknowtherearemanydeficiencies,suchaslackofabilitytoworkandinnovation,lackofpoliticaltheorytobeimprovedandsoon.InthefutureIwilltrytodothefollowing,Ihopetheleadershipandcomradesofmysupervisionandguidance:
1,consciouslystrengthenthestudy,tothetheoryoflearning,toprofessionalknowledgelearning,learningtocolleaguesaround,andgraduallyimprovetheirtheoreticallevelandoperationalcapacity.
2,toovercometheyounggasimpatient,sodowntoearth,improveworkinitiative,notafraidtodomorethings,notafraidtodosmallthings,improvethepracticeinthebittoimprovethemselves.
3,continuetoimprovetheirpoliticalaccomplishment,strengthenthesenseofpurposeofservingthepeople,andstrivetobecomeanoutstandingnationalcivilservants.
电气英文自我评价范文篇二
Thisyeariscomingtoanend,inordertobeabletoworkbetterinthenextyear,sumupexperience,adheretotheadvantagesandcorrectdeficiencies,accordingtocompanyrequirements,summarizedasfollows:
inayear'swork,throughthesummary,althoughmadesomeprogress,Alotofshortcomingsanddeficiencies.Asanelectricalandmechanicalworkshopelectricaltechnicians,intheproductionofworkisonlyconstantlysumupthelessonslearnedandfoundthatinordertomaketheirownfasterprogress.
First,in-depth,solidwork
Asanelectricaltechnicianintheelectromechanicalworkshopofthecoalpreparationplant,mymainresponsibilityistoberesponsibleforthemanagementofelectricaltechnologyintheelectromechanicalworkshop,toworkoutthemaintenancearrangementoftheelectricalequipmentandthecorrespondingmanagementrulesandtechnicaloperationmeasures,organizethestafftodowellinthebusinesstraining;Oftenin-depthsite,continuetopromotenewtechnologyandnewtechnologies.
Overthepastyear,Ihavebeenworkinghard,fulfillingmydutiesseriously,constantlyimprovingmyselffromthetechnicalandmanagementlevel,andhavemadegreatachievementsinallaspects.Iworkintheworkshopwiththesamebelowthemasteroftheworkers,equipmentproblemsencounteredactivelytothescenetodealwithfailures,eliminatehiddendangers.Insistonthesceneeverydaytochecktheoperationofequipment,highandlowvoltageequipmentforpowersupplyanddistribution;masterproductionprocessofcoalpreparationtolearntheprincipleofcentralizedcontrol;understandthecontrolsignalroutinglayout,informationtransmission.Nowmanyaspectshavemadegreatprogress,forexample:
thecommunication2××stationsystem,theelevatorrunningsystem,automaticcontrolsystemconcentrator,filterclosed-loopcontrolsystem,Kingconfigurationsystem,pressurizedfiltersystem,themainPlantandnewplantcoalwashingsystem,fromshallowtodeepgraspthebasiccontrolstructureandprincipleofthesystem.SoIhaveaverythoroughunderstandingoftheproductionprocessofcoalwashing,andhavelearnedtheknowledgeandtheactualproductionofeffectivecombinationforthefuturetobettertheorywithpractice,betterpromotetheproduction,betterreducetheworkersThemasterofthelaborintensity,moreeffectivetoimprovelaborproductivity,forenterprisesandthecommunitytocreatemorebenefitslaidasolidfoundation.OtheraspectsofmeticulousimprovementandcompletionofelectricalsafetyregulationsandmeasurestoseriouslymonitortheimplementationoftheannualmaintenanceintheXX11,throughthereplacementandoverhaulofthetransformer,butalsolearnedalotofthingsusuallydonotsee,soIcoalwashingPlantelectricalequipmentwithadeeperunderstanding.
Materialplantoprovidetimely,comprehensive,accuratesparepartsparametersistheguaranteeofnormaloperationoftheequipment,Iamresponsiblefortheelectricalequipmentmaterialsplantoreportwork,atwork,Iranthescene,checktheproblem,sothatsparepartscanbemorecomprehensiveandreliable,Toavoidthelackofsparepartsanddelaythestatusofproduction.Andthroughthelow-voltagepowerdistributionroomtofindtheproblem,andothertechnicalstafftogetherproposedthetransformationoflow-voltagedistributionroome