天翼宽带光盘安装使用说明Tianyi broadband CDROM installation instructions.docx

上传人:b****2 文档编号:24362929 上传时间:2023-05-26 格式:DOCX 页数:8 大小:18.46KB
下载 相关 举报
天翼宽带光盘安装使用说明Tianyi broadband CDROM installation instructions.docx_第1页
第1页 / 共8页
天翼宽带光盘安装使用说明Tianyi broadband CDROM installation instructions.docx_第2页
第2页 / 共8页
天翼宽带光盘安装使用说明Tianyi broadband CDROM installation instructions.docx_第3页
第3页 / 共8页
天翼宽带光盘安装使用说明Tianyi broadband CDROM installation instructions.docx_第4页
第4页 / 共8页
天翼宽带光盘安装使用说明Tianyi broadband CDROM installation instructions.docx_第5页
第5页 / 共8页
点击查看更多>>
下载资源
资源描述

天翼宽带光盘安装使用说明Tianyi broadband CDROM installation instructions.docx

《天翼宽带光盘安装使用说明Tianyi broadband CDROM installation instructions.docx》由会员分享,可在线阅读,更多相关《天翼宽带光盘安装使用说明Tianyi broadband CDROM installation instructions.docx(8页珍藏版)》请在冰豆网上搜索。

天翼宽带光盘安装使用说明Tianyi broadband CDROM installation instructions.docx

天翼宽带光盘安装使用说明TianyibroadbandCDROMinstallationinstructions

天翼宽带光盘安装使用说明(TianyibroadbandCD-ROMinstallationinstructions)

CodeforsafetymanagementofBeijinggasstation

ChapterIGeneralProvisions

Article1inordertostrengthenthecity'sgasstation(hereinafterreferredtoastherefuelingstation)ofthesafetymanagement,protectpeople'slivesandpropertysafety,accordingtothe"People'sRepublicofChinaproductionsafetylaw","People'sRepublicofChinafire","dangerouschemicalssafetymanagementregulations","Beijingcitysafeproductionregulations","gasstationdesignwiththeconstructionstandards"andtherelevantprovisions,combinedwiththeactualsituationofourcity,theenactmentofthisspecification.

Second,themanagementnormsapplytothecity'sadministrativeareasofoperatinggasfillingstationsafetymanagement.Thesafetymanagementofnonoperatinggasstationsshallrefertoandimplementthemanagementrules.

Thesecondchapteroperatingconditions

ThirdoperatinggasstationsintheadministrativeareaofthisMunicipalitymustobtainthe"dangerouschemicalsbusinesslicense"inaccordancewiththeprovisionsoftheadministrativemeasuresfortheoperationofdangerouschemicalsinBeijing.

Fourthgasstationconstructionprojectsmustbecarriedoutbythepublicsecurityfiredepartmentfiresafetyinspectionandacceptance.Thelightningprotectionequipmentatthefillingstationshallbetestedeverysixmonths.

Fifthrefuelingstationsmustbewiththeoutsideworldhasobviousisolationfacilitiesandclearexit,entrance,andotherunitsshallsetupthegasstationbusinessrelatedarea.

Sixthgasstationsshouldestablishandimprovetheresponsibilitysystemforproductionsafetyatalllevels,definetheresponsiblepersonnel,thecontentofresponsibilityandassessmentrequirements,andearnestlyimplement.

Seventhgasfillingstationsshallformulatesafetyrulesandregulationsandrelatedoperatingprocedures,andstrictlyenforcethem.

(a)refuelingstationshoulddevelopstaffsafetyeducation,trainingandexaminationmanagementsystem,safetyinspectionmanagementsystem,safetymanagementsystemoffacilities,equipment,safetyrewardsystem,fireandexplosionofworkplacemanagementsystemmanagementsystem,hiddenrectification,productionsafetyaccidentreportingandhandlingsystem,laborprotectionsuppliesdistributionmanagementsystem.Antistatic,lightningprotectionsystemofsafetymanagement,thedutyandtheshiftsafetymanagementsystemsafetyregulations;

(two)fillingstationsshallformulaterulesforfillingandfillinggas,operatingproceduresformeteringandoperationproceduresfordischargingoil(gas).

Thethirdchapterisaboutthesafetymanagementofemployees

Themainpersonresponsiblefortheeighthgasstations(legalrepresentativeorlegalperson)isresponsibleforthesafetyworkofthisstation,andimplementsthesafetyrulesandregulationsofthisstation.

Ninthrefuelingstationsandthemainpersoninchargeofsafetymanagementpersonnelmusthavethestationintherefuelingactivitiesofthecorrespondingsafetyknowledgeandmanagementability,andbytheBeijingMunicipalAdministrationofproductionsafetysupervisionandexaminationcertificates.

Tenthfillingstationsmustbeequippedwithfull-timeorpart-timesecuritymanagementpersonnel,responsibleforinspectionandsupervisionoftheimplementationofsafetymanagementmeasures.

Eleventhgasfillingstationemployeesmustundergoprofessionalskillstrainingandenterprisesafetytraining,andtheassessmentshallbecarriedoutaftertheoperation.

Thefourthchapteristhemanagementofbuildinginstation

Twelfthstationsinfillingstationsshouldmeetthefollowingrequirements:

(1)thedoorsandwindowsofthedormitoryshallnotbedirectedtowardtheoiltankareainthestationandtherefueling(gas)machine;

(two)itisstrictlyforbiddentostayovernightwithoutthestaffofthisunit;

(three)smokingandopenflameelectricstovearenotallowedinthedormitory;

(four)inthestationdormitory,apersoninchargeofthedormitoryshouldbeappointedtosupervise,inspectandmanageinaccordancewiththesafetymanagementregulationsofthedormitory.

Thirteenthgasfillingstationbusinessroom,restandotherplaces,prohibittheuseofliquefiedpetroleumgas,naturalgasandotheropenflameheatingandlife.

Thefourteenthstationboilershallmeetthefollowingrequirements:

(1)thereshallbeafirebarrierofnotlessthan3Hintheboilerroom,separatedfromotherrooms.

(two)theboilerroomdoorsandwindowsshouldnotbestraighttowardtheoilingmachine,fillingmachine,unloading,unloadingmooringpointofgasandtheventilationtube,dischargetube.

(three)theboilerchoosesthesmallboilerwiththeratedheatsupplynotgreaterthan140KW,theboilerchimneyshouldbehigherthantheroof2Mandabove,andtheeffectivemeasuresshouldbetakentopreventtheMarsfromescaping.

Thefifthchapterisaboutthesafetymanagementofequipmentandfacilitiesinstation

Fifteenthrefuelingstationsandaheightofnotlessthan4.5m,andedgeandplanedistancerefuelingorfuelingmachineofnotlessthan2m.

Sixteenthrefuelingorfillingmachineandstationdistancenotlessthan5m.

Thedistancebetweenseventeenthundergroundoiltanksandimportantpublicbuildingsshallnotbelessthan50m;thedistancebetweenLPGtanksandimportantpublicbuildingsshallnotbelessthan100m.

Thedistancebetweentheeighteenthtanksandtheopenflameorthesparkdischargeshallmeetthefollowingrequirements:

firstclassstationis30m,thetwostationis25m,andthethreestationis18m.

ThedistancebetweenanLPGtankandanopenflameorasparkdischargesiteshallcomplywiththefollowingrequirements:

firstclassstationis45m,stationtwois38m,andthethreestationis33m.

ThedistancebetweenanundergroundLPGtankandanopenflameorasparkdischargesiteshallcomplywiththefollowingrequirements:

firstclassstationis30m,thetwostationis25m,andthethreestationis18m.

Iftheoilandgasdualrecoverysystem,accordingtothe"automobilerefuelingstationdesignandconstructionspecifications",therelevantprovisionsoftheappropriatereduction.

ShouldadopttheTN-Ssystemofpowersupplyanddistributionsystemfor380/220Vnineteenthgasstations,powersupplysystemofthecablemetalsheathorcablemetalprotectiontubeendsareconnectedtoground,powersupplyanddistributionsystemshouldbeinstalledwithpressureequipmentovervoltageleveladaptation(surgeprotectivedevice).

Twentiethoverheadcommunicationlinesandpowerlinesshallnotcrossthegasfillingstation.

Thetwenty-firstsetinthetentunderthelightsshouldbeusedinprotectivetypelamp.

Twenty-secondgasstationscanbeequippedwithsmallinternalcombustionpowergenerationgroup,theexhaustpipeofinternalcombustionengineshouldbeequippedwithflamearrester.

Twenty-thirdairconditionersandoutdoorunitsshallbeinstalledinnonexplosiveareas.

Twenty-fourthgasstations,refuelingstationbuildingshouldsetthecombustiblegasdetectionandalarmsystem.

Thesixthchapteristhemanagementoffirefacilities

Twenty-fifthrefuelingstationstoestablishcompulsoryfireteam,onceamonthtocarryoutfireprotectionknowledge,everyquarterbyafiredrill,toachievethe"three,three",thatisafirepronearea,knowtheaccidentemergencyplan,firealarm,knowledgeandmethods:

theuseoffirefightingequipment,willsavetheinitialfire.

Theallocationoffireextinguishingequipmentintwenty-sixthgasfuelingstationsshallmeetthefollowingrequirements:

(1)atleast18kgportabledryfireextinguishersor24kgportabledryfireextinguishersshallbeinstalledforevery2GasDispensers;lessthan2unitsand2unitsshallbeusedforthefillingmachine;

(two)every2tankersshallhavenolessthan1portableportablefireextinguishersand16Lfoamextinguishers;lessthan2unitsand2units:

(three)theundergroundtankshouldbeequippedwith135kgfireextinguishers.

Whenthedistancebetweenthetwodielectrictanksexceeds15m,theyshallbesetseparately;

(four)pump,compressoroperation(shed)shouldbeaskedbytheconstructionareaof50squaremeterseachsetof8kgportabledrypowderfireextinguishers1,thetotalnumbershouldnotbelessthan2;

(five)oneortwogasstationsshouldbeequippedwithfireblanket5,sand2m3,threegasstationsshouldbeequippedwithfireblanket2,sand2m3,refuelingstation,accordingtothesamelevelofgasstationconfigurationfireblanketandsand;

(six)LPGstations,fillingstationsandLPGstationsshouldbeequippedwithfirewatersupplysystem;

(seven)promotetheuseofnewefficientfireextinguishingequipment.

Twenty-seventhfireequipmentshouldbesetupspecialmanagement,regularinspection,fixedpoint,regularreplacement,toensuregoodandeffective.

Theseventhchapterissitesafetymanagement

Twenty-eighthrefuelingstationsshouldbeinastrikingpositiontosetsafetywarninglanguage,warningsigns.

Warningwordsinclude:

(1)fireworksarestrictlyforbiddeninthestation;

(two)thestationisstrictlyforbiddentorepairvehicles,percussion,ironandothereasilysparkingoperations

(three)motorvehiclesmustextinguishwhenrefueling;

(four)nouseofmobilephonesonthegas(gas)scene.

Twenty-ninthgasstationsshouldhavefull-time(orpart-time)safetymanagementpersonnelforsecuritycheck,andfillintheinspectionrecord.Safetyinspectionmainlyincludes:

theimplementationofsafetyresponsibilitysystem,thesafetyofoperationsiteandtheoperationofequipmentandfacilities