AnalysisofandStudyontheDifficultiesintheFireProtectionDesignofLargeCommercialComplex
Abstract
Firepropertiesofthelargecommercialcomplexhasbeensummarized.Basedonthefactthattherearecontradictionsbetweenwhatisrequiredforthelargecommercialcomplexinthefirecodeandtherealapplicationinpractice,difficultiesinfireprotectionofdesigninglargecommercialcomplexhavebeenanalyzed.
Keywords:
largecommercialcomplex;fireprotectiondesign;difficulty;researchstatus
1.Introduction
Inrecentyears,moreandmorelargecommercialcomplexeshaveappearedinChina.Thesecomplexesintegratedifferentbusinessesintoonlargebuilding,wherecustomerscandoshopping,eatorenjoythemselves.Accordingtothestatistics,nearly200largecomplexesinChinanowhaveindoorwalkingstreet,withdifferentkindsofshopsstandingalongbothsides.Andwhat’smore,theindoorwalkingstreetsharesthelargespacewiththeatrium.
Generallyspeaking,thelargecommercialcomplexismulti-functionalwithhighfireloadandlargeassemblyofpeople.Themechanismoftheoccurrenceoffireisdifferentfromthatoftheordinarybuildingsandthefirelossisalsoheavier.Asaresult,thiskindofcommercialcomplexneedshigherfiresafety.However,thecurrentnationalfirecodeonlygivestheminimumrequirements.Nospecificfiresafetyobjectivesareprovided.Therefore,itisquiteimportanttounderstandthedesignandresearchstatusofthelargecommercialcomplexandtoprovidesafe,reasonableandeconomicalfiredesignmethod.
2.Characteristicsoflargecommercialcomplexfire
2.1Highfireoccurrence
Thereareheavyfireloadsinsidethelargecommercialcomplex,whichincludemerchandiseslikeclothes,shoes,hatsandcombustibledecorations.Itiswidelyrecognizedthatelectricityistheimportantfactortocausefirehazard.Therefore,toprovideelectricityamongthesecombustiblesisverydangerous.However,inthelargecommercialcomplex,electricsystemsandequipmentareinstalledtoprovideelectricityforlighting,ventilatingandairconditioning.Ifthereisshortcircuit,spark,poorcontactorlongtimeelectrifyingofthelightsorelectricheater,firemaybecaused.Inaddition,otherfactorslikeimproperwelding,lightedcigaretteendsorarsoncancausefiretoo.
2.2Quickspreadoffireandsmoke
Iffireoccursinalargecommercialcomplex,itcanspreadveryquicklyandgrowintoalargefireinashorttime,whiletheshelteroftherackusuallydecreasethesensitivityofthefiredetectionsystemandcausedelay.Asaresult,firecan’tbedetectedandcontrolledtimely.Theotherreasonforquickfirespreadingisthattheverticalspaceformedbytheatriumandescalatorsinthecomplexmayhelpfireandsmoketospreadtothewholebuilding.
2.3Largecasualtiesandpropertyloss
Thelargecommercialcomplexusuallyaccommodatesvaluablemerchandisesandfacilities.Oncethereisafire,bigpropertylossisinevitable.Andwhat’smorefatalisthatthereareusuallylargeassembliespresent.TheheavysmokewithCO,CO2,NOx,HCNnotonlyaffectsthesafeandquickevacuationofthepeople,butalsoputthemindanger.AccordingtothestatisticsofJapanandUK,thepercentageofdeathscausedbysuffocationinthefirecanbeashighas78.9%.Asaresultofacomplicatedlayout,largeassemblyofpeople,longtimetoevacuate,thelargecommercialcomplexissusceptibletofatalfireaccidentswhichusuallysufferheavycasualties.Forexample,onSept.30,1997,afireoccurredinasupermarketonthethirdfloorofashoppingmallinChangchun,Jilinprovince.Itcaused11deathsand2injuries.Theburningareareached4500m2andmostofthecommoditiesinsidethesupermarketwereburnt.ThedirectpropertylosswasRMB14,611,000Yuan.
3.Analysisofdifficultiesinfireprotectiondesignoflargecommercialcomplex
Comparingwiththeordinarybuilding,thecommercialcomplexislargeandusuallymulti-functional.Duringtheconstruction,newmaterials,technologiesandstructuresareemployed,whichoftenbringaboutdifficultiesinitsfireprotectiondesign.
3.1Therearenoapplicablerequirementsforthefireprotectiondesignofthecomplexinthecurrentnationalfirecode
Forthefireprotectiondesignofalargecommercialcomplex,thecurrentnationalstandardhascoveredthefollowingpoints:
(1)thebuildingstyleandthedistributionofbusinessoperationsinsidethecomplex;
(2)thestyleoftheindoorwalkingstreet;
(3)howtodeterminethefireloadofthecomplex;
(4)ifthewalkingstreetinsidethecomplexcanbeusedasasafeevacuationarea?
Ifyes,whatkindofconditionsshouldbeprovided;
(5)theoccupancydensity,firefightingequipment,smokecontrolpatternaswellasotherimportantdesignparameters;
(6)thesizeandseparationoftheshopsalongthebothsidesofthewalkingstreet.
3.2Therearelimitationsinthefirecodeforthefiredesigningofthelargecommercialcomplex
Herejustgivesanexampletoillustratethelimitation.Therequirementsfortheevacuationofthepeoplein“Codefordesignofshopbuildings”JGJ48-88can’tmeettheneedoftheevacuationsystemofthelargecommercialcomplex.PersonnelconvertquantityinJGJ48-88isbasedonthebusinessareaandtheareaofthestorage,whichistotallyunfitforthenewlayoutofacomplexwithmodernideasandnovelties.TheevacuationwidthcalculatedaccordingtothemethodgiveninJGJ48-88isusuallytoobig.Asaresult,morestaircaseswillberequired,whichnotonlybringsgreatdifficultiesinthedesigningoftheevacuationsystem,butalsocreateenormouswaste.Atthesametime,thelayout,structureaswellastheaestheticqualityofthecomplexwillbeaffectedtoo.[68~70]Therefore,itisimpropertodeterminetheevacuationwidthorotherparametersaccordingtothecalculationmethodgiveninthecurrentstandard.
3.3Someoftherequirementsinthecurrentcodecan’tbeimplementedeasilyinthefireprotectiondesignoflargecommercialcomplex
(1)Firecompartmenttion.
Itisrequiredinthecurrentfirecodethatthefirecompartmentofthecommercialbuildingsshallnotbelargerthan5000m2.However,thebuildingareaofalargecommercialcomplexisusuallyasbigashundredsofthousandsofsquaremeters.Ifthefirecompartmentisdividedstrictlyaccordingtotherequirementsofthefirecode,manymanyfirecompartments,staircasesandexitswillbeprovided.Theresultofthisisthatthearrangementsofthebusinessareawillbegreatlyaffectedandthefunctionofthecomplexwillbecompletelylimited.
(2)Fireseparation.
Thetypicalproblemforthefireprotectiondesignoflargecommercialcomplexisthatitstraveldistanceandevacuationwidthcan’tmeettherequirementsofthecode.
“Codefordesignofbuildingfireprotectionandprevention”GB50016-2006requiresthatthelineardistancebetweenanypointintheshoppingareasinsidetheClassAandClassBbuildingsandthenearestexitshouldnotbelargerthan30m;whenthebuildingisprotectedcompletelybysprinklersystem,themaximumsafetraveldistanceshallbe37.5m;theendofthestaircaseonthefirstfloorshallbeprovidedwithexitdirectlyleadingtooutdoororshallbeenlarged.Whenthebuildingisnotmorethan4stories,theexitdirectlyleadingtooutdoorcanbelocatedattheplacethatisnotmorethan15mawayfromthestaircase.Butinpractice,itisnotenoughforlargecommercialcomplextoprovideemergencystaircasesonlyattheperipheryofthebuildingbecausethecomplexisusuallyquitelonganddeep.Therefore,morestaircasesshallbeprovidedinthemiddle.Accordingtotherequirementsofthefirecode,thesestaircasesinthemiddlepartofthebuildingmusthaveexitsdirectlyleadingtotheoutdoor,whichiscompletelyoutofthequestion.
“Codeforfireprotectiondesignoftallbuildings”GB50045-95(2005edition)requiresthatthelineardistancebetweenanypointintheshoppingareasandthenearestexitshouldnotbelargerthan30m.Inpractice,theemergencystaircasesofthehigh-risecommercialbuildingsarealsoprovidedattheperipheryofthebuilding.Thelineardistancebetweentheleastfavorablepointtotheneareststaircaseisoftenlargerthan30m.Butinordertomeettherequirementofthetallbuildingcode,staircasesinthemiddleofthebuildingmustbeprovided.However,thestaircasesinthemiddleofthebuildingcan’tdirectlyleadtooutside.
(3)Firefighting.
Both“Codefordesignofbuildingfireprotectionandprevention”and“Codeforfireprotectiondesignoftallbuildings”requirethatwherethelengthofthebuildingalongthestreetismorethat150morthetotallengthofthebuildingismorethan220m,awellsituatedfirevehicleaccessshallbeprovidedtocrossthebuilding.Forlargecommercialcomplex,itisquitedifficulttoprovidefirevehicleaccesstocutthebuildingapart.Therefore,inpractice,manydesignersproposetousethewalkingstreetasthefirevehicleaccess,butitcan’tmeetthefirefightingneedofthefirevehicles.
4.Currentresearchstatusathomeandabroad
CurrentlyinChina,theresearchesonthefireprotectiondesignoflargecommercialcomplexmainlyfocusontheanalysisofsomefireprotectionsystem.
ZhaoHualianganalyzedthecommonlyusedindexandparametersofevacuationdesign.Parametersusedfordesignofevacuationsystemoflargecommercialcomplexsuchasnumberofpeople,evacuationwidth,traveldistanceaswellasemergencylightinghavebeendiscussed.
Aimatthedifficultiesindesigningofthefirepartitionincommercialconstruction,ZhengYanqiuanalyzedthegeneralrequirementsforthe