1、商场消防设计中英文对照外文翻译文献商场消防设计中英文对照外文翻译文献(文档含英文原文和中文翻译)原文: Analysis of and Study on the Difficulties in the Fire Protection Design of Large Commercial ComplexAbstractFire properties of the large commercial complex has been summarized. Based on the fact that there are contradictions between what is required
2、 for the large commercial complex in the fire code and the real application in practice, difficulties in fire protection of designing large commercial complex have been analyzed.Key words:large commercial complex; fire protection design; difficulty; research status1. IntroductionIn recent years, mor
3、e and more large commercial complexes have appeared in China. These complexes integrate different businesses into on large building, where customers can do shopping, eat or enjoy themselves. According to the statistics, nearly 200 large complexes in China now have indoor walking street, with differe
4、nt kinds of shops standing along both sides. And whats more, the indoor walking street shares the large space with the atrium.Generally speaking, the large commercial complex is multi-functional with high fire load and large assembly of people. The mechanism of the occurrence of fire is different fr
5、om that of the ordinary buildings and the fire loss is also heavier. As a result, this kind of commercial complex needs higher fire safety. However, the current national fire code only gives the minimum requirements. No specific fire safety objectives are provided. Therefore, it is quite important t
6、o understand the design and research status of the large commercial complex and to provide safe, reasonable and economical fire design method.2. Characteristics of large commercial complex fire2.1 High fire occurrenceThere are heavy fire loads inside the large commercial complex, which include merch
7、andises like clothes, shoes, hats and combustible decorations. It is widely recognized that electricity is the important factor to cause fire hazard. Therefore, to provide electricity among these combustibles is very dangerous. However, in the large commercial complex, electric systems and equipment
8、 are installed to provide electricity for lighting, ventilating and air conditioning. If there is short circuit, spark, poor contact or long time electrifying of the lights or electric heater, fire may be caused. In addition, other factors like improper welding, lighted cigarette ends or arson can c
9、ause fire too.2.2 Quick spread of fire and smokeIf fire occurs in a large commercial complex, it can spread very quickly and grow into a large fire in a short time, while the shelter of the rack usually decrease the sensitivity of the fire detection system and cause delay. As a result, fire cant be
10、detected and controlled timely. The other reason for quick fire spreading is that the vertical space formed by the atrium and escalators in the complex may help fire and smoke to spread to the whole building.2.3 Large casualties and property lossThe large commercial complex usually accommodates valu
11、able merchandises and facilities. Once there is a fire, big property loss is inevitable. And whats more fatal is that there are usually large assemblies present. The heavy smoke with CO, CO2, NOx, HCN not only affects the safe and quick evacuation of the people, but also put them in danger. Accordin
12、g to the statistics of Japan and UK, the percentage of deaths caused by suffocation in the fire can be as high as 78.9%. As a result of a complicated layout, large assembly of people, long time to evacuate, the large commercial complex is susceptible to fatal fire accidents which usually suffer heav
13、y casualties. For example, on Sept. 30, 1997, a fire occurred in a supermarket on the third floor of a shopping mall in Changchun, Jilin province. It caused 11 deaths and 2 injuries. The burning area reached 4500m2 and most of the commodities inside the supermarket were burnt. The direct property lo
14、ss was RMB 14,611,000 Yuan.3. Analysis of difficulties in fire protection design of large commercial complexComparing with the ordinary building, the commercial complex is large and usually multi-functional. During the construction, new materials, technologies and structures are employed, which ofte
15、n bring about difficulties in its fire protection design.3.1 There are no applicable requirements for the fire protection design of the complex in the current national fire codeFor the fire protection design of a large commercial complex, the current national standard has covered the following point
16、s:(1)the building style and the distribution of business operations inside the complex;(2 )the style of the indoor walking street;(3 )how to determine the fire load of the complex;(4)if the walking street inside the complex can be used as a safe evacuation area? If yes, what kind of conditions shoul
17、d be provided;(5)the occupancy density, fire fighting equipment, smoke control pattern as well as other important design parameters;(6)the size and separation of the shops along the both sides of the walking street.3.2 There are limitations in the fire code for the fire designing of the large commer
18、cial complexHere just gives an example to illustrate the limitation. The requirements for the evacuation of the people in “Code for design of shop buildings”JGJ48-88 cant meet the need of the evacuation system of the large commercial complex. Personnel convert quantity in JGJ48-88 is based on the bu
19、siness area and the area of the storage, which is totally unfit for the new layout of a complex with modern ideas and novelties. The evacuation width calculated according to the method given in JGJ48-88 is usually too big. As a result, more staircases will be required, which not only brings great di
20、fficulties in the designing of the evacuation system, but also create enormous waste. At the same time, the layout, structure as well as the aesthetic quality of the complex will be affected too.6870 Therefore, it is improper to determine the evacuation width or other parameters according to the cal
21、culation method given in the current standard.3.3 Some of the requirements in the current code cant be implemented easily in the fire protection design of large commercial complex(1)Fire compartmenttion.It is required in the current fire code that the fire compartment of the commercial buildings sha
22、ll not be larger than 5000m2. However, the building area of a large commercial complex is usually as big as hundreds of thousands of square meters. If the fire compartment is divided strictly according to the requirements of the fire code, many many fire compartments, staircases and exits will be pr
23、ovided. The result of this is that the arrangements of the business area will be greatly affected and the function of the complex will be completely limited.(2)Fire separation.The typical problem for the fire protection design of large commercial complex is that its travel distance and evacuation wi
24、dth cant meet the requirements of the code.“Code for design of building fire protection and prevention” GB 50016-2006 requires that the linear distance between any point in the shopping areas inside the Class A and Class B buildings and the nearest exit should not be larger than 30m; when the buildi
25、ng is protected completely by sprinkler system, the maximum safe travel distance shall be 37.5m; the end of the staircase on the first floor shall be provided with exit directly leading to outdoor or shall be enlarged. When the building is not more than 4 stories, the exit directly leading to outdoo
26、r can be located at the place that is not more than 15m away from the staircase. But in practice, it is not enough for large commercial complex to provide emergency staircases only at the periphery of the building because the complex is usually quite long and deep. Therefore, more staircases shall b
27、e provided in the middle. According to the requirements of the fire code, these staircases in the middle part of the building must have exits directly leading to the outdoor, which is completely out of the question.“Code for fire protection design of tall buildings” GB 50045-95(2005 edition) require
28、s that the linear distance between any point in the shopping areas and the nearest exit should not be larger than 30m. In practice, the emergency staircases of the high-rise commercial buildings are also provided at the periphery of the building. The linear distance between the least favorable point
29、 to the nearest staircase is often larger than 30m. But in order to meet the requirement of the tall building code, staircases in the middle of the building must be provided. However, the staircases in the middle of the building cant directly lead to outside.(3)Fire fighting.Both “Code for design of
30、 building fire protection and prevention” and “Code for fire protection design of tall buildings” require that where the length of the building along the street is more that 150m or the total length of the building is more than 220m, a well situated fire vehicle access shall be provided to cross the
31、 building. For large commercial complex, it is quite difficult to provide fire vehicle access to cut the building apart. Therefore, in practice, many designers propose to use the walking street as the fire vehicle access, but it cant meet the fire fighting need of the fire vehicles.4. Current resear
32、ch status at home and abroadCurrently in China, the researches on the fire protection design of large commercial complex mainly focus on the analysis of some fire protection system.Zhao Hualiang analyzed the commonly used index and parameters of evacuation design. Parameters used for design of evacuation system of large commercial complex such as number of people, evacuation width, travel distance as well as emergency lighting have been discussed.Aim at the difficulties in designing of the fire partition in commercial construction, Zheng Yanqiu analyzed the general requirements for the
copyright@ 2008-2022 冰豆网网站版权所有
经营许可证编号:鄂ICP备2022015515号-1