sciencedesignservice

BuildingServicesDesign

‘Contemporaryconstructivetechniqueisabsolutelyunsuitedtothisworldsubjecttoconstantchange’(PARICIO,I.ProyectoCasaBarcelona,ConstrumatBarcelona,2001,p.17.FreetranslationfromtheSpanishtextbyauthors).

Thedesignofinstallationsrefersheretoitbeingsuitablysettingupandtoitseasysubsequentmaintenanceandnotonly(obviously)toitsaestheticresult.

Therealopenfloorinmanyarchitecturalprojectsdoesnotlieonlyinthemoreorlesscomplexchangeofpartitions,butinthepossibilityofaccesstoallservices

demandedbytheusersinanylocation.Therefore,thelimitoftherealflexibilityisthelimitofuseofthewholeinstallationservicesinanyplaceofthebuilding.

Thedesignofdifferentinstallationshastraditionallyconstitutedanexcellentopportunitysothatarchitectsparticipateinthedesignofobjectsofdifferentscale,fromlampstoairconditioningductsintegratedinfaçade,withexamplessooutstandingastheconceptofservedandserverspacesbyKahn,attheSalkInstitute,aconceptthatinitselfgeneratessplendidbuildings,fundamentaltounderstandingthecontemporarydesignofarchitectureandinstallations;orinthesamewaythatWrightbuilttheLarkinbuildingin1905,where‘themachineryofthedifferentsupplysystemswithitsraceways,ventilationandheatingconduits,justasthestaircases,thatalsoserveasemergencyexit,arearrangedinfourpartsintheplan,locatedinthefourexteriorcornersofthebuilding,leavingthiswaythewholeinteriorsurfacetobeusedforjobs’(BROOKS,B.Wright,Taschen,Köln,2004,p.23.FreetranslationfromtheSpanishtextbyauthors).

Ontheotherhand,onecanpointouttheinterestofundergroundcarparksanddecksasthecontemporaryarchitecturalelementsthatshowtheinterdisciplinarynatureofthedifferentsubjectsthatmakeuptheconstruction,itsinternalorder,areflectionofwhathappensinsidethebuilding.Thus,TVaerials,satellitedishes,mobilephonesaerials,collectivechimneys,individualchimneys,coolingtowers,coolingunits,airconditioners,theextractorsofthecarparkingventilation,thebathroomsandtoiletsextractors...shapeandarepartoftheurbanlandscapeandoftheimageofthecity.Evenwhentheywillremainoutoftheglobaldesigninabuildingthatwouldbenothingwithoutthem?

Incertaintypologies,suchashigh-risebuildingsorthoseofgreatvolume,thedecisionaboutthelayingofinstallations,thewaythemaincentralizationsareraisedandthechoiceofthesystemforfireevacuation,arethegreatshapersofthebuildings.Thinkingaboutthesemattersgeneratedifferenttypologies,forexampletheHongKong&ShanghaiBankbyFosterhasonecentralizationperfloor;theParisianPompidouhastwo,andtheBancoBilbaobyOízaortheChaseManhattanBankhavefour,whereastheRichardsbuildingbyKahnhasonecentralizationpertower.

Wealsohavetothinkthateachbuildingtypologyneedsadifferentoutlineofthinking.Howisahighbuildingair-conditioned?

Whyareskyscrapersnotcrownedwithabigchimney?

Whyarethesedesigntechniquesnotusedinotherbuildings?

Onceagainasimilaritywiththeautomobileworldcanbeestablished:

inthesamewaythatadvancesinFormula1carscomesoonerorlatertosimplervehicles,theideasandadvancesincontrolandmanagementofenergyreservedforthemost‘sophisticated’buildingswillbeintroducedsoonerorlaterinthehousing.

Thearchitectswhohaveanalyzeddifferentnavalandaeronauticalreferencestoapplytheminarchitecturehavebeenmany,althoughinsomecasesitonlyformaloperationsweretransferredtotheirprojectandnotintellectualstrictness.Itissurprisingthatinahightonnageship,wheretheavailablespaceissotight,machineshavewhattheyneedintheirtechnicalroomstomakemaintenanceeasy(withoutit,theship-machinedoesnotwork)andhoweverinsomeprojectsofarchitecture,installationshavetobeadjustedtominimumareas,inplanandsection,thataredesignedinthiswaywithoutreallyknowingwhy.Thecorrectdesignofinstallationsinarchitectureshouldbesituatedatapointofequilibriumandcompromisebetweenthevirtuesofthesesophisticatedmachines

(ships,aircraft...),thecoordinationbetweentheoccupancyofareasandthelayingofnetworksofthedifferentinstallations,andtherestofaesthetic,functionalandeconomicparametersthatconstitutearchitecture.Itmakesnosense,therefore,totalkabouthiddenorvisibleinstallation:

eacharchitecturemusthaveitcorrespondingdesignofinstallations.Itisnotaboutdifferentrealitiesthatjointogethertoformabuilding,butdifferentvisionsofthesameobject.

Inaddition,wemustrememberthateverymachinebreaksdownandsoonerorlaterithastobereplaced;theusefullifeoftheinstallationsisdifferentfromthatofthebuildings,whichiswhyitisnecessarytothinkabouthowthemachineswillbereplacedwithoutdisruptioninsidethebuildingandwithoutbotheringitsinhabitants.Thesolutioniseasy:

planthenecessaryspaceforthemachines,theirmaintenanceandtheirreplacement.

Machinesneedspaceandthenetworksneedaccessibility,avalidstatementbothinbuildingsandatanurbanlevel.

Toendthissection,somequestions:

Whenwillwehaveatourdisposalinkitchenselementssoversatilein-servicesasthedentist’schairwithitselectricity,waterandplumbingintakes?

Whyaretherenosolutionssimilartotheequipmentofahairdresser’stoevacuatethewatersinresidentialplumbing?

Howlongwilltheuserstaketodemandthesamecomfortsandfacilityofuseandmaintenanceintheircarsandintheirhomes?

Whycanthewiringofacarcanbemodifiedinminutesandahouseneedsmaybedaysandseveraldifferenttradesmentosimplychangetheelectricaloutlets?

 

FireSafety

Asintroductionquotationinstructs,thepreventionoffiresinbuildingsisanobsessiveconcernforhumankind,becausethefirethatheatsisthefirethatcandestroyeverything.

Notonlydotherulesoffireprotectionrefertotheinstallationsthatmustbeplacedtodetectandsmotherafire,butalsotothefireresistanceofthematerialsused,thelayoutofstaircaseandemergencyexits,evacuationroutes...theyarerulesofminimumsthatalwaysbeimproved.Themeasuresoffireprotectionaredividedinto:

-Passives.Theyaremeasuresdirectedtofacilitatetheevacuationofthebuilding(therulespenalizedeadends)andensurethecontainmentofthefireinsideanenclosureuntilthearrivaloftheextinctionservices(requirementsofstructuralandconstructiveelementsfireresistance).Thesemeasuresalsoaffectotherinstallations.Forexample,anairpipecanbeisolatedagainstfirewhenitgoesthroughdifferentfireareas,withisolationandfirebreakdoors,butthefirstmeasureistoproposeadesignofpipesinsuchawaythatthesealwaysstayinthesamefirearea.

-Actives.Theycovertheinstallationsofdetection(firedetectors,manualpushbuttons,doorretainers,controlstations...)andthedifferentsystemsofalarm,signsandextinction(fireextinguisher,hydrant,pumpingequipment,firehydrantcabinets,sprinklers,extinctionbygaseousagentsorspecificextinctionforkitchens).Ofthesemeasures,wewillnowmentionaseriesofpointswithgreaterarchitectoniccontent,whichcanevengosofarastoconditionthefinalshapeofthebuilding.

-Zoningandfirestabilityintheformationofvolumesandstructuralframeworkofthebuilding.Atthispoint,makingtheproperdecisionsasregardsthematerialsusedandthearrangementofthedifferentfireareascansimplifyothersolutionsoffireprotection.Forinstance,althoughtherulesallowtheincreaseoftheareaofasectorbyplacingsprinklers,itworksouteasiertoplacefire-resistantslidingdoorswithretainersatstrategicpointsinordertoavoidanexcessivecomplexityoftheinstallations.

-Zoningdependingonthebuildingtypology.Therequirementsofevacuationofanofficebuilding,anentertainmentcenterorahospitalarenotthesame.Inthislast,thehorizontalevacuationtootherfireareascanbeprioritized,andnotverticalevacuation,formovingtheconvalescentpatientsquicklyandsafely,inwhichcase,moreover,itisnecessarytoestablishintermediatesareasofevacuationthathavespecificinstallations(oxygen,vacuum,powerpoints,etc.)inordertotakecareoftheemergencypatientsuntiltheextinctionservicescome.

-Drainage.Itisainstallationthatalsomustbeconsideredwhensectorzingabuilding,becausedrainagepipesconstitutepathwaysforfire(whichriskcanbeminimizedbyplacingFRrings),anormalcircumstanceforexampleinthezoningbetweenacarparkwithdwellingsabove,orbetweendamppremisesinbuildingswithverticallysuperimposedareas.

-Staircaseandevacuationroutes.Inbuildingsofacertainmagnitude,itiscrucialtodesignthebuildingconsideringtheseelementsfromthefirstmoment.Improvingtheevacuationofabuildingthroughaspeciallyprotectedstaircasewithdirectventilationtotheoutside,orwithventilationbyoverpressure,cangeneratetwobuildingsthat,withthesameschedule,areformallydifferent,withtheaddedfactorthatinthelattercasedemandsconstantmaintenanceofaninstallationthatguaranteespeople’ssafety,andthisisnotsointheformer,althoughcaringequallyfortheirsafety.Asasampleoftherelationshipbetweendifferentinstallations,wecanstatehow,inapublicbuilding,improvementoffireevacuationbyinstallingmoreouterdoorsincreasesaccesssecurityinthebuilding,whichiscompensatedforbytheintroductionofadditionalanti-burglarmeasures(door