ArubaSiteSurvayExample参考格式

 

SBC

WirelessSiteSurvey

CoverageAssessmentReport

 

DutyFreeAmericas

Laredo,TX

 

PreparedBy:

RobStewart

Date:

10-1-04

 

TableofContents

OVERVIEW3

SpecificTasksPerformedDuringtheWirelessSiteSurveyCoverageAssessment:

3

Disclaimer4

ContactInformation:

5

AreasofProposedRFCoverage:

6

SpecificSiteDescription:

6

SiteSurveyTestParameters6

SystemConfigurationSummary:

7

EquipmentList:

7

SpecialConsiderationsandAssumptions:

7

NetworkInformation:

8

SystemComponentLocations:

10

Power,CablingandNetworkingRequirements:

59

FacilityDrawings:

60

AppendixA-CableandMountingGuidelines:

71

AppendixB–PoweroverEthernetDiagram72

AppendixC-NetworkCablingBestPracticesGuidelinesforCat5/5eUTPcable73

AppendixD-NetworkDesignBestPracticesGuidelines76

OVERVIEW

On9/29/04,aWirelessSiteSurveyCoverageAssessmentwasconductedforDutyFreeAmericasinLaredo,TX.ThisWirelessSiteSurveyCoverageAssessmentwasconductedtodeterminethenumberofaccesspoints,antennatypesandassociatedinstallationhardwarerequired,andtheirrespectivelocationsinthefacilitytomeetthecoveragerequirementsasstatedinthestatementofwork.

ThisreportisbaseduponthespecificfindingsoftheWirelessSiteSurveyCoverageAssessment,aswellascoveragerequirementfactsasknownatthetimeandasprovidedintheScopeofWork.AllfindingswillapplytoDutyFreeAmericasSiteCoverageAssessmentunlessDutyFreeAmericas:

∙Physicallychangesorremodelsthesitewithneworrearrangedstructuralitems

∙ChangesthestackingorstorageofcertainitemsthataffectsRFpropagation

∙InstallsadditionalequipmentemittingelectromagneticradiationfieldsaffectingRFpropagation

ThisWirelessSiteSurveyCoverageAssessmentReportcontainsallrequiredspecificationstofacilitatetheinstallationandimplementationoftheWireless802.11CommunicationsSystemandachievethedesiredcoverage.ThisreportistobeusedbytheSystemArchitectasatooltoincorporateintotheirdesignthenumberofaccesspoints,antennatypesrequiredandtheirrespectivelocationsinthefacility.TheNetworkCableCo.andtheRFInstallationTeamcanalsousethisreporttoinstallalltherequiredcomponentsasidentifiedbymodelorspecificationnumber,location,andterminationpoints.

SpecificTasksPerformedDuringtheWirelessSiteSurveyCoverageAssessment:

▪PerformwalkthroughoffacilitytoverifycoverageareaasdefinedintheScopeofWork.

▪Determinedthenumberofaccesspoints,antennatypes,mountingrequirementsandcablingrequirements(data&power)requiredtoprovidethedesiredwirelesscoverageandtheirrespectivelocationsinthefacility.

▪DeterminetheproperRFchannelassignmentsandRFpowersettingsforeachaccesspoint.

▪PerformabesteffortidentificationofanydetectedpotentialsourcesofRFinterferencethatcouldimpactthewirelessnetworkperformance.

▪Surveytheexistingnetworkconnectionsandequipmenttoconfirmthatminimalacceptablehardwareandsoftwarerequirementsaremet.

▪Evaluationofspaceandelectricalrequirements.

▪Physicallytagallaccesspointandantennalocations.

▪ProvideacompletedWirelessSiteSurveyCoverageAssessmentReport.

.

Disclaimer

TheWirelessSiteSurveyCoverageAssessmentisnotaSystemNetworkDesignorCablePlantExtension.Thisservicedoesnotincludenetworkutilizationtesting,wirelesssecurityauditornetworkdesign.Theaccesspointsbeingproposeduseradio(s)thatisunlicensed.SBCcannotguaranteetherewillneverbeothersourcesofinterferenceorradiofrequenciesintheareaswithinthisproposedwirelesssystem.ThisdocumentcanbeusedalongwilltheenclosedBestPracticeWirelessDesignGuidelinestoformulateaSystemDesign.

TheSBCrepresentative(s)responsibleforthecontentsofthisdocumentare:

Name

TelephoneNumber

PrimaryCustomerRepresentative(s)supplyinginformationusedinthisdocumentare:

Name

TelephoneNumber

AllenRodriquez

954-986-7656

ContactInformation:

SBCAccountManagementInformation

AccountManagerName

JeffKettering

CompanyName

StreetAddress

2500N.AndrewsAve.Ext.

City,StateZip

Pompano,FL33064

Telephone

(954)317-0754

Email

Jk8535@

SBCProjectManagementInformation

ProjectManager:

ProjectManagerPhoneNumber:

ProjectManagerE-mailAddress:

CustomerInformation

CustomerName:

DutyFreeAmericas

StreetAddress:

110International

City,State,Zip

Laredo,TX.78045

PrimaryCustomerContact:

AllenRodriguez

PrimaryContactPhoneNumber:

954-986-7656

SiteContact:

SitePhoneNumber:

AreasofProposedRFCoverage:

PriortoconductingtheRFSiteSurveyadiscussionandbrieftourwereconductedforsiteorientationandtodeterminewhichareasofthefacilitywouldrequireRFnetworkoperation.DutyFreeAmericasrepresentativeAllenRodriguezcoordinatedtheorientationwalk-through.

SpecificSiteDescription:

TypeofFacilitySurveyed:

WarehouseComplex

TotalSquareFootageCovered

Approximately200,000sqfttotal

DescriptionofCoverageAreas:

Large/Smallwarehouse,Motorpool,ExecutiveOffices,andoutdoorareasbetweeneachofthesebuildings.

TotalNumberofBuildings:

Four

NumberofFloorsinTallestBuilding:

Two

Floor,WallsandCeilingMaterial:

Concrete,Drywall,CorrugatedSteel,Rediron.

CeilingHeight:

9ft–30ft.

ApproximateInventoryLevel:

85%

ExistingWiredNetworkType:

Cat5

ExistingRFNetworks:

None

SiteSurveyTestParameters

AccessPointType:

Cisco1200g

ClientDevice:

Cisco350g

DiagnosticProgram:

AironetClientUtility

PingPacketSize:

1024

SurveyedDataRate:

36mb

ChannelsUtilized

1,6,11

SystemConfigurationSummary:

TotalNumberofAccessPoints

23

TotalNumberofBridgeUnits

0

NumberofOutsideAntennasforAP’s

10

NumberofOutsideAntennasforbridge

2

NumberofInsideAntennas

22

NumberofAntennasUsingDiversity

22

PowerOption:

A/CorPoE

PoE

AreThereLiftRequirements?

IfSo,ThenWhatTypeofLiftisRequired?

Yes,ascissorliftthatreaches30ft.willberequiredtocompletethisinstall.

EquipmentList:

Qty

Description

PartNumber

18

ArubaAP-70A/B/GaccessPoint

AP-70

5

ArubaAP-80MoutdoorAccessPoint

Ap-80M

18

PoEInjector(forAPinMotorPool)

PD-3001-AC

22

6.0dBiArubaIndoor/Omniantenna

AP-ANT-2

10

6.0dBiArubaOutdoor/Omniantenna

AP-ANT-80

12

LightningArrestors

AP-LAR1

17

AP-70MountingKit

AP-70-MNT

2

GBIC-T

11

HyperlinkPre-DrilledFiberglassNEMAEnclosure

NB141207-40F

46

6’PatchCables

2

Aruba-2400controllers

2

Securitybundlelicenses

SpecialConsiderationsandAssumptions:

OutdoorAPsandBridgeUnitswillNOTrequireanantennaextension.

ThecustomercurrentlyhasCisco3550seriesswitchesthatprovidePoE,theymayormaynotusethesefortheinstall,ifnottheywillneedtoorderPoEinjectorsforeachAccessPointandBridgeunit.

NetworkInformation:

ThefollowingNetworkComponentsandtheirlocationswereidentified:

MDF/IDFLocations

SwitchType(Mfg&Model#)

NumberofSwitchPortsAvailable

NumberofPatchPanelPortsAvailable

AdditionalA/COutletsNeeded

MDF-ExportOffice

Cisco2970

Cisco2900

Cisco3550

Cisco3550

Cisco3550

20

9

1

2

22

6

3open

IDF2-ExecutiveOffices

Cisco3550

Cisco3550

10

17

24

2open

IDF3-SmallWarehouse

Cisco3550

15

0

2open

IDF4-LargeWarehouse

Cisco3550

Cisco3550

Intel210T

3

3

2

42

2open

NOTINSTALLED

IDF5-MotorPool

N/A

N/A

N/A

2open

AdditionalNetworkComments

IDF5needstobeinstalled.Thiscouldbea4porthublocatedintheMotorPooltoconnecttheNon-RootBridgetotheinteriorAccessPoint#17.

Thesitehas3550routersonsite,buttheLargeWarehousewouldneedandadditionalonetomakeroomforalloftheAP’s.

IfthecustomerdecidestousePoEinjectorsthentheywouldneedtobeaddedtothepartslist.

 

MDFIDF2

IDF3IDF4

IDF5-PossibleLocation

SystemComponentLocations:

AccessPoint#1:

EquipmentType:

ARUBAAP-70

AntennaType:

IntegratedOmni-directional–Diversity

Location

ImportDepartment/OverJoseCoronado

MDF/IDFLocation

IDF2

DistancetoMDF/IDF

50

DataCableDropRequired

Yes

A/CPowerDropRequired

No

NEMAEnclosureRequired

No

DropCeilingEnclosureRequired(optional)

NO

MountingHeight

9ft.

MountedTo

DropCeiling

LocationMarkedBy

4-½”ColoredDots

DiversityUtilized

Yes

RFChannelSetting

AUTO

APPowerSetting

AUTO

APMountingInstructions:

APcanbeinstalleddirectlyontopofdropceiling.UsinganArubamountingkitwillallowfordrop-ceiling“T-Bar”exposedmounting.

AntennaMountingInstructions:

Antennaisintegratedandshouldbeinaverticalposition.

DataandPower:

DataandPowerwillbefedviathenewCat5ecablerun.

 

AccessPoint#1Pictures

 

AccessPoint#2:

EquipmentType:

ARUBAAP-70

AntennaType:

IntegratedOmni-directional–Diversity

Location

Traffic/NearTeresaEnriquez

MDF/IDFLocation

IDF2

DistancetoMDF/IDF

70

DataCableDropRequired

Yes

A/CPowerDropRequired

No

NEMAEnclosureRequired

No

DropCeilingEnclosureRequired(optional)

NO

MountingHeight

9ft.

MountedTo

DropCeiling

LocationMarkedBy

4-½”ColoredDots

DiversityUtilized

Yes

RFChannelSetting

AUTO

APPowerSetting

AUTO

APMountingInstructions:

APcanbeinstalleddirectlyontopofdropceiling.UsinganArubamountingkitwillallowfordrop-ceiling“T-Bar”exposedmo