NetApp存储测试报告.docx
《NetApp存储测试报告.docx》由会员分享,可在线阅读,更多相关《NetApp存储测试报告.docx(22页珍藏版)》请在冰豆网上搜索。
![NetApp存储测试报告.docx](https://file1.bdocx.com/fileroot1/2022-11/17/8880d86e-5bec-4991-9185-e9cbe6580789/8880d86e-5bec-4991-9185-e9cbe65807891.gif)
NetApp存储测试报告
NetApp存储测试报告
1目的
本次测试测试针对NetApp存储的特点、性能等方面进行相关的验证及测试,为今后的存储设备选型提供一定的技术依据。
备注:
在测试项目中的输出结果,仅仅作为参考结果,实际结果与信息时间为实际测试结果为准。
2术语
术语
解释
应用
XX应用转接应用(OLTP)的模拟程序,
CFO
ClusteredFailover
CIFS
CommonInternetFileSystem
CLI
CommandLineInterface
NDMP
NetworkDataManagementProtocol
GUI
GraphicalUserInterface
HA
HighAvailability
HBA
HostBusAdapter
MPIO
MultiPathIO(MicrosoftHAdrivercomponent)
NFS
NetworkFileSystem
SAN
StorageAreaNetwork
IOPS
input/outputpersecond
ORT
overallresponsetime
iSCSI
InternetSmallComputerSystemInterface
FCP
FibreChannelProtocol
TCP
TransportControlProtocol
UDP
UserDatagramProtocol
HTTP
HypertextTransferProtocol
HTTPs
SecureHyperTextTransferProtocol
FTP
FileTransferProtocol
NIC
NetworkInformationCenter
3测试内容
●存储系统的可管理性测试
●存储系统的可靠性和可用性
●存储系统的扩展性、兼容性
●存储性能测试
4测试准备
4.1测试拓扑结构
4.2测试设备配置
4.2.1服务器配置
本次测试的服务器由XX方提供,主要为一台SunEnterprise2900充当服务器
服务器配置
主机型号
数目
CPU
(个)
内存(G)
千兆光纤网卡/台
自适应网卡/台
存储光纤卡/台
Sun服务器
SunEnterpriseV890
1
2
8
2
2
1
相关的应用软件如下表所示:
软件产品
软件版本
Patch
32/64位
操作系统
Legato
NetworkerBackup
7.22
64
Solaris5.9
118558-14
4.2.2网络配置
FAS3050直接用一条LC光纤线与SUN服务器V890连接。
4.2.3存储配置
存储服务器:
NetAppFAS3050具体配置:
磁盘容量:
2T裸容量的磁盘。
磁盘转速10000RPM,单个磁盘的裸容量为144G,总共为14个。
4.3测试工具
◆对于存储的功能测试,测试厂商需根据测试环境、案例要求准备测试工具,提供相关的监控软件对测试过程进行监控,对监控指标进行记录。
4.4存储的可管理性
测试是否具有强大的管理功能,主要包括以下一些方面。
具体可结合NetApp公司提供的测试方案进行具体测试。
功能
备注
基于GUI图形界面
FilerView
基于WEB管理支持
FilerView
图型界面是否友好、易于使用
是
操作界面简单、统一
是
是否能对系统的运行健康状况和性能指标进行实时的监测
是
监控内容是否全面
是
基于SNMP网络协议管理支持
是
SNMPTrap
是
是否支持对异地存储集中管理
是
存储状态实时监控
是
磁盘损坏管理软件是否报警
是
磁盘状态是否报警
是
重构RAID中是否影响性能
是
重构RAID后是否可用
是
是否有对重构过程的监控
是
是否支持图形方式快照
是
快照过程的监控
是
4.5存储可靠性、可用性测试
测试项目
目的
步骤
预期结果
1.检测电源冗余
系统是否可在单电源情况下正常工作(证明电源无单点故障)并且电源可在线更换
存储设备具有完善的电源、风扇冗余功能;电源风扇模块可热插拔;
1.确认应用均正常运行。
2.在应用不间断的情况下,随机选择拔下一个电源风扇模块(模拟电源故障情况),并通过管理软件检测整个过程中系统是否发生中断
应用无中断
3.拔出机头1个电源风扇模块;
应用无中断
4.拔出第1个磁盘柜的1个电源风扇模块;
应用无中断
5.恢复磁盘柜1的失效电源;
应用无中断
6.恢复磁盘柜2的失效电源;
应用无中断
7.恢复机头的失效电源;
应用无中断
附:
存储控制台输出
HN>WedSep2011:
43:
22CST[ses.status.psWarning:
warning]:
DS14-Mk2-FCshe
lf1onchannel0cpowerwarningforPowersupply1:
non-criticalstatus;DCund
ervoltagefault.Thismoduleisontherearsideoftheshelf,attheleft.
WedSep2011:
43:
34CST[ses.status.psError:
CRITICAL]:
DS14-Mk2-FCshelf1onch
annel0cpowererrorforPowersupply1:
criticalstatus;powersupplyfailed.T
hismoduleisontherearsideoftheshelf,attheleft.
WedSep2011:
43:
42CST[monitor.chassisPowerSupply.degraded:
notice]:
Chassispo
wersupply2isdegraded:
PSU2ACFailed
WedSep2011:
43:
43CST[monitor.chassisPowerSupply.degraded:
notice]:
Chassispo
wersupply2isdegraded:
PSU212VFailed
WedSep2011:
43:
43CST[monitor.chassisPowerSupply.degraded:
notice]:
Chassispo
wersupply2isdegraded:
PSU25VFailed
WedSep2011:
43:
50CST[monitor.chassisPowerSupply.ok:
info]:
Chassispowersupp
ly2isOK
WedSep2011:
43:
50CSTlastmessagerepeated2times
WedSep2011:
44:
00CST[monitor.globalStatus.critical:
CRITICAL]:
Diskshelffau
lt.
WedSep2011:
44:
27CST[ses.status.psInfo:
info]:
DS14-Mk2-FCshelf1onchannel
0cpowersupplyinformationforPowersupply1:
normalstatus
WedSep2011:
45:
00CST[monitor.globalStatus.ok:
info]:
Thesystem'sglobalstat
usisnormal.
2.检验系统全局热备份盘功能
测试磁盘阵列是否能够通过动态备盘自动接管模拟的故障磁盘
热备份盘为全局热备份,可自动接管失效磁盘。
系统中未使用的磁盘均为热备份盘
1.确认应用均正常运行。
2.在应用不间断的情况下,由用户任意选择拔出使用中的两个磁盘(模拟磁盘故障),通过管理软件检测整个过程中系统是否发生中断,系统是否始终能够正常工作;
系统中的热备份盘自动接管失效磁盘,并开始RAID重构,重构完成时间为4个小时。
注:
热备份盘与失效磁盘位于系统的相同磁盘柜中。
3.重新插入步骤2中拔出的磁盘;
该磁盘被系统自动识别为新的热备份盘。
针对RaidDP的数据重构,首先我们建立900GB的LUN,并mount在”/mnt”目录下,已写入LUN的数据大约在671GB左右,同时,在数据重构的过程中,同时有三个带库数据流同时写入LUN,以此模拟在存储硬盘在两个磁盘同时损坏的情况下,数据不会掉失和数据重构时间。
附:
主机状态输出
root@v890c#df-k
FilesystemkbytesusedavailcapacityMountedon
/dev/md/dsk/d10103324603060571716856530%/
/proc0000%/proc
mnttab0000%/etc/mnttab
fd0000%/dev/fd
swap1699323248169931841%/var/run
swap169947681584169931841%/tmp
/dev/md/dsk/d1002823504876114212521838485822%/test
/dev/md/dsk/d1202063407212219993831%/oracle_log
/dev/md/dsk/d11062036944507236163442274%/oracle
/dev/md/dsk/d802064612189501691148949144%/catadata
/dev/md/dsk/d60120498954653742675391969855%/backup
/dev/md/dsk/d901033246010265102188711%/catabak
/dev/dsk/c3t7d0s092896320067174542024792814874%/mnt
存储控制台输出:
HN*>WedSep2015:
45:
52CST[raid.rg.recons.done:
notice]:
/aggr0/plex0/rg0:
reconstructioncompletedfor0a.29in4:
00:
26.80
WedSep2015:
46:
01CST[raid.rg.recons.done:
notice]:
/aggr0/plex0/rg0:
reconstructioncompletedfor0a.19in3:
59:
40.50
以上显示为RaidDP重构的时间为4小时。
3.测试RAID方式切换
测试对一个RAID组进行RAID方式的动态切换(RAID-4,RAID-DP)
RAID方式切换简易、方便。
不会中断应用。
从RAID-4方式切换到RAID-DP方式时,由于需要构建第2块校验盘,需要占用存储设备的部分CPU与时间。
1.确认应用均正常运行。
2.在应用