配电自动化远方终端DTU测试规范.docx
《配电自动化远方终端DTU测试规范.docx》由会员分享,可在线阅读,更多相关《配电自动化远方终端DTU测试规范.docx(35页珍藏版)》请在冰豆网上搜索。
配电自动化远方终端DTU测试规范
配电自动化远方终端DTU测试规范
北京市电力公司
配电自动化远方终端DTU测试规范,适用开闭站、配电室、电缆分界室三遥站点,
北京市电力公司
二〇一〇年九月
目录
一、总则.......................................................................................................................................31.1编写目的..............................................................................................................................31.2引用标准..............................................................................................................................3二、检验项目及要求....................................................................................................................4三(结构及配置测试....................................................................................................................53.1目的....................................................................................................................................53.2指标....................................................................................................................................53.3测试记录..............................................................................................................................53.4测试备忘..............................................................................................................................6四(软硬件平台测试....................................................................................................................74.1目的.....................................................................................................................................7
4.2指标.....................................................................................................................................74.3测试记录..............................................................................................................................74.4测试备忘..............................................................................................................................7五、电源性能测试........................................................................................................................85.1目的.....................................................................................................................................85.2指标.....................................................................................................................................85.3测试记录..............................................................................................................................85.4测试备忘..............................................................................................................................9六(基本功能测试......................................................................................................................106.1目的...................................................................................................................................106.2指标..................................................................................................................................106.3测试记录............................................................................................................................116.4测试备忘............................................................................................................................13七、数据处理及传送功能测试...................................................................................................147.1目的.................................................................................................................................147.2指标..................................................................................................................................147.3测试记录............................................................................................................................157.4测试备忘............................................................................................................................15八、本地及远程维护..................................................................................................................168.1目的...................................................................................................................................168.2指标...................................................................................................................................168.3测试记录............................................................................................................................168.4测试备忘............................................................................................................................17九、通信功能测试......................................................................................................................189.1目的..................................................................................................................................189.2指标..................................................................................................................................189.3测试记录...........................................................................................................................199.4测试备忘............................................................................................................................23十、绝缘电阻、绝缘强度、高低温、湿热、振动测试.............................................................2310.1目的................................................................................................................................2310.2测试记录.........................................................................................................................23
-1-
10.3测试备忘.........................................................................................................................25十一、电磁兼容性测试...............................................................................................................26
11.1目的................................................................................................................................26
11.2指标要求.........................................................................................................................26
11.3测试记录.........................................................................................................................26
11.4测试备忘.........................................................................................................................29
-2-
一、总则
1.1测试目标
本测试规范适用于北京市电力公司开闭站、配电室、电缆分界室三遥站点应用的配电自动化远方终端DTU。
为规范现有市场各厂家终端设备,特制定本测试方案,以此为标准对终端设备进行全面的检测试验。
测试人员须具备电力终端专业测试经验。
测试终端应满足本方案提出的相关功能、性能指标要求。
1.2引用标准
下列标准所包含的条文,通过在本规范中引用而构成为本规范的条文。
本技术规范中未明确要求的条款,应执行最新颁布的IEC标准、国家标准、行业标准。
当标准中的条款与本规范存在偏差时,应以本技术规范为准。
DL/T814-2002配电自动化系统功能规范
GB/T13729-2002远动终端设备
DL/T630—1997交流采样远动终端技术条件
DL/T721—2000配网自动化系统远方终端
DL/T597-1996低压无功补偿控制器订货技术条件
GB/T15576-1995低压无功功率静态补偿装置
JB7113-93低压并联电容器装置
GB4208—2008外壳防护等级(IP代码)
DL/T634.5101-2009远动设备及系统第5-101部分:
传输规定
DL/T634.5104-2009远动设备及系统第5-104部分:
传输规定
京电调[2005]20号北京电力公司配网自动化101/104通信规约实施细则
-3-
二、检验项目及要求
2.1基本要求
(1)本次检测分为9大检测项目,每项检测项目包含若干子项目。
(2)参检设备必须通过所有子项目的最低检测标准,方可视为检测通过并获取检测报告,
否则中国电科院不向参检单位提供检测报告。
2.2评价标准
(1)设备首次检测过程中,如存在三项及以上问题需要整改,则认定该设备不能通过检测。
(2)设备首次检测过程中,如存在两项及以下问题需要整改,在规定时间内,最多可进行
两次改进,检测报告中需完整记录修改过程;如同一问题两次改进后仍不能通过检测,
则认定该设备不能通过检测。
(3)对于全部检测项目均通过的设备,以整改项目数量与整改次数作为排名依据。
(4)最终检测结果由北京市电力公司与中国电科院共同裁定。
检验序号检验项目
结构及配置1
软硬件平台2
电源性能3
基本功能4
数据处理及传输5
本地及远程维护6
通信功能7
绝缘电阻、绝缘强度、高低温、湿热、振动8
电磁兼容性9
表1
-4-
三(结构及配置测试
3.1目的
测试终端单元结构及可扩展性。
3.2指标
(1)采用19英寸标准机箱,结构设计应紧凑、小巧,内部各设备模块布局合理,接线清
晰明了,各设备安装/拆卸方便,装置运行状态有信号灯指示。
(2)容量满足不低于8个高压回路三遥标准化配置,实现每路开关配置不少于5个遥信、
3个电流(Ia/Ic/Io)、2个电压和1路遥控。
(3)遥信、遥测、遥控功能模块独立配置、支持热拔插,能够根据需求方便、灵活的进行
容量扩充。
(4)功能模块应支持热插拔功能,遥控板的热插拔不能引起误动。
(5)对外通信端口不少于4个串口,2个以太网口。
(6)终端装置应有独立的保护接地端子,并与外壳和大地牢固连接。
接地位置清晰明显。
(7)各种印字标识美观协调,字迹附着牢固;各种接线方便可靠,标识准确清晰易懂。
3.3测试记录
DTU测试记录表
测试项目结构及配置测试日期:
测试人员:
测试记录
项次测试功能测量或观察项目测试记录结果
?
合格1结构尺寸19英寸标准机箱?
不合格
遥信、遥测、遥控模块?
合格2模块配置独立配置,方便、灵活?
不合格
的进行配置。
遥信、遥测、遥控模块?
合格3热拔插功能独立配置、支持热拔插。
?
不合格
不低于8个高压回路三?
合格遥标准化配置?
不合格
?
合格遥信点数不小于40点?
不合格4单元标配容量遥测点数不小于26个?
合格遥测?
不合格
遥控点数不小于8路开?
合格关遥控?
不合格
-5-
可扩充至满足12组高?
合格5可扩充容量压回路三遥标准化配置?
不合格
的要求
?
合格至少4个串口?
不合格6通信接口?
合格至少2个网口?
不合格
具有电源、运行、装置?
合格7装置运行指示灯异常告警等指示灯?
不合格
表2
3.4测试备忘
-6-
四(软硬件平台测试
4.1目的
了解终端是否采用先进、常用的硬件和软件平台。
4.2指标
(1)主机应采用不低于32位微处理器(DSP处理器)系列芯片。
主要元器件采用工业级
芯片(元器件)、板卡。
(2)装置主机采用实时多任务嵌入式操作系统。
如VxWorks、μC/OS一?
等。
应用程序应
基于实时多任务嵌入式操作系统软件平台进行开发,用以保证配网终端装置进行故障
识别、规约转换、数据管理等复杂功能要求。
4.3测试记录
DTU测试记录表
测试日期:
测试项目软硬件平台测试人员:
测试记录
项次测试功能测量或观察项目测试记录结果
主机采用微处理器(DSP?
合格1不低于32位处理器)系列芯片?
不合格
?
合格2操作系统实时多任务嵌入式?
不合格
记录参加测试的软3软件版本件版本号
表3
备注:
测试记录中将填写所用处理器型号,装置存储芯片型号及容量,操作系统名称。
4.4测试备忘
-7-
五、电源性能测试
5.1目的
测试装置电源是否能同时接纳交流、直流供电,并且能自动切换;装置是否对电源有监视功能,自维护管理功能;测试装置输入、输出电压是否符合规范。
5.2指标
(1)装置电源能同时接纳交、直流供电方式。
(2)正常情况下,应由两路交流电源互为备用供电方式,可互相切换。
一旦两路交流电源
均中断,装置应在无扰动情况下自动切换到直流供电方式;当交流电源恢复供电时,
装置应自动切回交流供电方式。
(3)外部电源失电后,蓄电池为终端与通信设备供电时间应大于等于8小时,且在8小时
内,应至少保证主电源停电后能支持分合闸操作4次。
(4)电源模块应为操作机构提供48V操作电源,功率大于等于300W,为通信装置提供24V
通信电源,功率大于等于15W。
(5)装置应具备电池活化管理功能,能够自动实现对蓄电池的定期充放电,且充放电时间
可进行设置。
(6)装置能实现对供电电源的状态监视,电源模块具有明显指示灯并能将电源供电状况以
遥信方式上传到上级系统;包括交流电状态、电池是否欠压,电池维护状态。
(7)后备电源采用德国阳光原装进口蓄电池,型号:
A412/8.5SR,8.5Ah。
(8)输入电压范围:
220V+/-20,AC
(9)输出电压范围:
40V,55VDC
或20V,28VDC
5.3测试记录
DTU测试记录表
测试日期:
测试项目电源指标测试人员:
测试记录
项次测试功能测量或观察项目测试记录结果
装置同时接收两路交流电源互
为备用方式供电;
交流供电时同时给直流电源蓄装置电源同时接纳电池充电,交流失电自动切换?
合格1交、直流供电,交、到直流供电,交流恢复自动切?
不合格直流自动无扰动切换换到交流供电。
切换过程装置
工作正常。
交流输入有状态指示灯及遥信
-8-
具备电池欠压告警,?
合格电池组输出电压过低2有欠压指示灯及遥信;?
不合格监测试验具备电池放电关断;
输出电压准确度:
?
合格3电源模块输出电压40V,55V;?
不合格或20V,28V
电源模块功率范围试通信电源24V、不小于15