Section7CFR1755900

[CodeofFederalRegulations]

[Title7,Volume11]

[RevisedasofApril1,2002]

FromtheU.S.GovernmentPrintingOfficeviaGPOAccess

[CITE:

7CFR1755.900]

 

TITLE7--AGRICULTURE

CHAPTERXVII--RURALUTILITIESSERVICE,DEPARTMENTOFAGRICULTURE

PART1755--TELECOMMUNICATIONSSTANDARDSANDSPECIFICATIONSFORMATERIALS,EQUIPMENTANDCONSTRUCTION--TableofContents

Sec.1755.900RUSspecificationforfilledfiberopticcables.

(a)Scope

.

(1)Thissectioncoverstherequirementforfilledfiberopticcablesintendedforaerialinstallationeitherbyattachmenttoasupportstrandorbyanintegratedself-supportingarrangement,forundergroundapplicationbyplacementinaduct,orforburiedinstallationseitherbytrenchingorbydirectplowing.

(i)Theopticalwaveguidesareglassfibershavingdirectly-appliedprotectivecoatings,andarecalled``fibers'',herein.Thesefibersmaybeassembledineitherloosefiberbundleswithaprotectivecoretube,encasedinseveralprotectivebuffertubes,orintightbuffertubes.

(ii)Fillers,strengthmembers,corewraps,andbeddingtapesmaycompletethecablecore.

(iii)Thecoreorbuffertubescontainingthefibersandtheintersticesbetweenthebuffertubes,fillers,andstrengthmembersinthecorestructurearefilledwithasuitablematerialtoexcludewater.

(iv)Thecablestructureiscompletedbyanextrudedoverallplasticjacket.Thisjacketmayhavestrengthmembersembeddedinit,insomedesigns.

(v)Buriedinstallationrequiresanarmorundertheouterjacket.

(vi)Forself-supportingcabletheouterjacketmaybeextrudedoverthesupportmessengerandcablecore.

(2)Thecableisfullycolorcodedsothateachfiberisdistinguishablefromeveryotherfiber.Abasiccolorschemeoftwenty-fourcolorsallowsindividualfiberidentification.Coloredtubes,binders,threads,stripings,ormarkingsprovidefibergroupidentification.

(3)Cablemanufacturedtothissectionmustdemonstratecompliancewiththequalificationtestingrequirementstoensuresatisfactoryend-useperformancecharacteristicsfortheintendedapplications.

(4)OpticalcabledesignsnotspecificallyaddressedbythissectionmaybeallowedifacceptedbyRUS.Justificationforacceptanceofamodifieddesignmustbeprovidedtosubstantiateproductutilityandlongtermstabilityandendurance.

(5)AllcablessoldtoRUSborrowersforprojectsinvolvingRUSloanfundsunderthissectionmustbeacceptedbyRUSTechnicalStandardsCommittee``A''(Telephone).Forcablesmanufacturedtothespecificationofthissection,alldesignchangestoanaccepteddesign

mustbesubmittedforacceptance.RUSwillbethesoleauthorityonwhatconstitutesadesignchange.

(6)TheAmericanNationalStandardInstitute/InstituteofElectricalandElectronicsEngineers,Inc(ANSI/IEEE),1993NationalElectricalSafetyCode(NESC)referencedinthissectionisincorporatedbyreferencebyRUS.ThisincorporationbyreferencewasapprovedbytheDirectoroftheFederalRegisterinaccordancewith5U.S.C.552(a)and1CFRpart51.CopiesofANSI/IEEE1993NESCareavailableforinspectionduringnormalbusinesshoursatRUS,room2845,U.S.DepartmentofAgriculture,Washington,DC20250-1500orattheOfficeoftheFederalRegister,800NorthCapitolStreet,NW.,suite700,Washington,DC.CopiesareavailablefromIEEEServiceCenter,445Hoes

Lane,Piscataway,NJ08854,telephonenumber1(800)678-4333.

(7)AmericanSocietyforTestingandMaterialsSpecifications(ASTM)A640-91,StandardSpecificationforZinc-CoatedSteelStrandforMessengerSupportofFigure8Cable;ASTMB736-92a,StandardSpecificationforAluminum,AluminumAlloy,andAluminum-CladSteelCableShieldingStock;ASTMD1238-90b,StandardTestMethodforFlowRatesofThermoplasticsbyExtrusionPlastometer;ASTMD1248-84(1989),StandardSpecificationforPolyethylenePlasticMoldingand

ExtrusionMaterials,ASTMD1535-89,StandardTestMethodforSpecifyingColorbytheMunsellSystem;ASTMD3349-86,StandardTestMethodforAbsorptionCoefficientofCarbonBlackPigmentedEthylenePlastic;ASTMD4565-90a,StandardTestMethodsforPhysicalandEnvironmentalPerformancePropertiesofInsulationsandJacketsforTelecommunications

WireandCable;ASTMD4566-90,StandardTestMethodsforElectricalPerformancePropertiesofInsulationsandJacketsforTelecommunicationsWireandCable;ASTMD4568-86,StandardTestMethodsforEvaluatingCompatibilityBetweenCableFillingandFloodingCompoundsandPolyolefinCableMaterials;andASTME29-90,StandardPracticeforUsingSignificantDigitsinTestDatatoDetermineConformancewithSpecifications,referencedinthissectionareincorporatedbyreference

byRUS.TheseincorporationsbyreferenceswereapprovedbytheDirectoroftheFederalRegisterinaccordancewith5U.S.C.552(a)