Healthsafety

HealthandSafety

EducationandTraining

Article87ofRegulationsonFactoryHealthandSafety:

Factoriesshalleducatetheirworkersinthecorrectuseofprotectionarticles.Workersperformingdangerouswork(e.g.electricalandgasworkers)shouldbetaughtfirstaidmethods.

Article55oftheLaborLawofthePeople’sRepublicofChina:

Laborersperformingspecialoperationsshallreceivespecialtrainingandobtainthecompetencyforspecialoperations.

Point5ofParagraph2ofChapter2ofPracticalAffairsofLawsonLaborSafetyandHealth:

“Specialoperations”mentionedinArticle55oftheLabortothoseoperationsthatposeamajordangertotheoperatorsthemselves,otherpersonsandthesurroundingenvironment,suchas:

(1)Electricalwork;

(2)Boilerwork;(3)Operationofpressurizedcontainers;(4)Weight-liftingoperation;(5)Explosiveoperation;(6)Metalweldingandgascutting;(7)Underpitgasinspectionincoalmines;(8)Drivingofmotorvehicles;(9)Drivingofmotorvesselsandturbineoperation;(10)Elevatederectionworkonbuildings.

Point3ofArticle14oftheFireControlLawofthePeople’sRepublicofChina:

Governmentaldepartments,socialorganizations,enterprises,institutions,townsandvillagesshallcarryoutfirepreventionawarenesseducationamongtheirstaffmembersinviewoftheirownfeatures.

Article30oftheFireControlLawofthePeople’sRepublicofChina:

Onthebasisofactualneeds,governmentaldepartments,socialorganizations,enterprises,institutions,townsandvillagesmaysetupvoluntaryfirebrigadesmadeupofstaffmembersorvillagers.

ExitsofFactoryBuilding

Article3.5.1ofFirePreventionStandardforBuildingDesign(newrevisionofGBJ16-87):

Thenumberoffireexitsofafactorybuildingshallnotbelessthan2.But,ifthefollowingrequirementsaremet,theremaybeonly1:

ForafactorybuildingofCategoryC(see★ofremarks),theareaofeachfloorisnotmorethan250m2andthenumberofworkersworkingatthesametimeisnotmorethan20;forfactorybuildingsofCategoryDandC(see★ofremarks),theareaofeachfloorisnotmorethan400m2andthenumberofworkersworkingatthesametimeisnotmorethan30;

EvacuationPassages,SignsandEmergencyLights

Article14.6oftheFireControlLawofthePeople’sRepublicofChina:

Governmentaldepartments,socialorganizations,enterprisesandinstitutionsshallmakesurethattheevacuationpassagesandfireexitsremainunblockedandsetupfireevacuationsignsthatmeetstateregulations.

Article3.5.4oftheFirePreventionStandardforBuildingDesign(newrevisionofGBJ16-87):

Thewidthoftheevacuationstaircase,passageanddoorsofeachfloorofafactorybuildingshallbecalculatedinthefollowingway:

nolessthan0.6m/100personsforthe1stand2ndfloors;nolessthan0.8m/100personsfor3rdfloor;nolessthan1.0m/100personsfor4th(andabove)floor.Whenthenumberofworkersondifferentfloorsaredifferent,thetotalwidthofthestaircaseshallbecalculatedonafloorbasisandthetotalwidthofthestaircasesoflowerfloorsshallbecalculatedonthebasisoftheabovefloorwiththelargestnumberofworkers.However,theminimumwidthofstaircaseshallnotbelessthan1.1m.Thetotalwidthoftheexternalgateofthegroundfloorshallbecalculatedonthebasisofthelargestnumberofpeopleofthefloorortheabovefloor.Buttheminimumwidthoftheevacuationdoorsshouldpreferablybeabove0.9mandtheevacuationpassageabove1.4m.

Article7.4.1oftheFirePreventionStandardforBuildingDesign(newrevisionofGBJ16-87):

Theevacuationstairwellandthefrontroomshallnotbeusedaswaterheatingroom,fuelstorageroom,non-closedliftwellorfortheaccommodationofflammablegaspipelines.

Article7.4.2oftheFirePreventionStandardforBuildingDesign(newrevisionofGBJ16-87):

Forbuildingsthatshouldhavesmoke-preventionstairwells,theirexternalstairwellsmaybeusedasauxiliarysmoke-preventionstaircase.Butthenetwidthshouldnotbelessthan90cmandtheobliquityshouldnotbemorethan45o.Theheightoftheguardrailsshouldnotbelessthan1.1m.Fortheoutdoorevacuationstaircasesofotherbuildings,theobliquitymaybelessthan60oandthenetwidthmaybemorethan80cm.Boththeoutdoorevacuationstaircasesandtheexitplatformsoneachfloorshouldbemadeofflameretardantmaterials.Thefireresistancelimitoftheplatformshouldbeatleast1handthatofthestaircasesatleast0.25h.Excepttheevacuationdoor,thereshouldnotbeotheropeningsonthewallwithin2maroundthestaircase.Theevacuationdoorshouldnotdirectlyfacethestaircase.

Article7.4.5oftheFirePreventionStandardforBuildingDesign(newrevisionofGBJ16-87):

Thenethorizontalspacebetweentwosectionsofanevacuationstaircaseofapublicbuildingshouldpreferablybeatleast15cm.

Article7.4.7oftheFirePreventionStandardforBuildingDesign(newrevisionofGBJ16-87):

Theevacuationdoorsofcivilianandfactorybuildingsshouldbeopeninthedirectionofevacuation.Foraroomaccommodatingnomorethan60peoplewheretheaveragenumberofpeopletobeevacuatedthrougheachdoordoesnotexceed30(excludingproductionroomsofCategoryAandB),theopeningdirectionofthedoorsisnotlimited.Side-pullingdoors(excludingwarehouses)shouldnotbeusedforevacuationpurposeandtheuseofrotarydoorforevacuationpurposeisstrictlyforbidden.

Article10.2.6oftheFirePreventionStandardforBuildingDesign(newrevisionofGBJ16-87):

Allunitsshallprovideemergencylightsforevacuationpassages,existandstairwells.

Article10.2.9oftheFirePreventionStandardforBuildingDesign(newrevisionofGBJ16-87):

Emergencyevacuationsignsshallbeplacedonthetopofexitdoor,orattheturningofstairwaywithheightofbelow1meter.Thedistancebetweensignsandtheexitshallnotexceed20meters.Emergencylightandemergencyevacuationsignsshallbeintheformofprotectiveboxmadeofglassorothernon-flammablematerials.

Article11ofFactorySafetyandHealthRules:

Hatchwaysandwalkingplatformsshouldhaveguardrailsofnolessthan1m.

ManagementofFireControlFacilities

Article14.5ofFirePreventionLawofthePeople’sRepublicofChina:

Inaccordancewithrelevantstateregulations,governmentaldepartments,socialorganizations,enterprisesandinstitutionsshallhavefirecontrolfacilitiesandequipment,setupfirecontrolandsafetysignsandorganizeregularinspectionsandrepairtoensurethatthesefacilitiesandequipmentarekeptingoodandeffectiveconditions.

Article21ofFirePreventionLawofthePeople’sRepublicofChina:

Nounitsorindividualsmaydamageordiverttootherpurpose,dismantleorinactivatefirecontrolfacilitiesandequipmentwithoutauthorization,orburyandoccupyfirehydrants,takeupfirepreventionspacesandblockfirecontrolpassages.

Article10ofFirePreventionLawofthePeople’sRepublicofChina:

UponthecompletionofaconstructionprojectcontainingafirecontroldesignconductedinaccordancewithrequirementsoftheStateTechnicalStandardsonFireControlforEngineeringConstruction,theprojectmustgothroughacceptancecheckonfirecontrolbyrelevantpublicsecurityfirecontrolinstitutions;projectwithoutgoingthroughtheacceptancecheckorconsideredunqualifiedaftertheacceptancecheckshallnotbeputintouse.

Selection,QuantityandAllocationofFireControlEquipment

InstallationofFireExtinguishers

Article2.4.3.16ofManualofBasicDataforIndustrialSafetyandHealth:

Forproductionwarehouses(see★ofRemarks)ofCategoryCfirehazard,thenumberoffireextinguishersis:

1forevery80m2offactorybuildingand1forevery100m2ofwarehouse.

Article4.0.4oftheDesignStandardforEmplacementofFireExtinguishersinBuildings(GBJ40—90Document):

Thenumberoffireextinguishersprovidedforundergroundstructuresshallbemorethanthatfortherelatedgroundstructuresby30%.

Article4.0.5oftheDesignStandardforEmplacementofFireExtinguishersinBuildings(GBJ40—90Document):

Forplacesequippedwithfirehydrantsandfirecontrolsystems,thenumberoffireextinguishersmaybecutinthefollowingway:

(1)By30%forplacesequippedwithfirehydrants;

(2)by50%forplacesequippedwithfirecontrolsystems;(3)by70%forplacesequippedwithbothfirehydrantsandfirecontrolsystems.

Article4.06oftheDesignStandardforEmplacementofFireExtinguishersinBuildings(GBJ40—90Document):

Forplaceswhereinflammablematerialsarestockpiledinopenair,liquidofCategoriesA,BandCisstoredandtanksofinflammablegasarekept,thenumberoffireextinguishersmaybecutby70%.

Article4.07oftheDesignStandardforEmplacementofFireExtinguishersinBuildings(GBJ40—90Document):

Thenumberoffireextinguishersforoneplaceshouldnotbelessthan2andshouldnotexceed5foreachemplacementpoint.

Article5.1.3oftheDesignStandardforEmplacementofFireExtinguishersinBuildings(GBJ40—90Document):

Itisadvisabletoputportablefireextinguishersonhooks,bracketsorcaseswiththetopnotmorethan1.5mandthebottomnotlessthan0.15mabovetheground.

Article3.0.2oftheFirePreventionStandardforBuildingDesign(newrevisionofGBJ16-87):

Thetypeoffireextinguishersselectedshallmeetthefollowingstipulations(see★★ofRemarksforfiresofA,B,CandDtypes):

(1)ToputoutfiresoftypeA,water,foam,phosphoricacidammoniumsaltpowderandalkylhalidefireextinguishersshouldbeselected;

(2)ToputoutfiresoftypeB,powder,foam,alkylhalideandcarbondioxidefireextinguishersshouldbeselected.Chemicalfoamfir