Locations—model55xandOpenPower720
Usethisinformationtohelpyoumapalocationcodetoapositionontheserverforthe9133-55A,9406-550,9113-550,andOpenPower®720models.
Note:
Theknownlogicallocationcodesforthisunitarelistednexttothecorrespondingphysicallocationinthefollowinginformation.Ifyouareworkingwithalogicallocationcodeforthisunitanditisnotlistedinthefollowinginformation,contactyournextlevelofsupport.
Thefollowingdiagramsshowfieldreplaceableunit(FRU)layoutinthesystem.Usethesediagramswiththefollowingtables.
Ifyouneedaddressinformation,refertoAddresses–model55xandOpenPower720.
Figure1.Frontviewofthesystem
Figure2.Backviewofthesystemwith2RIO/HSLportsontheplanarand1buscardslot.Buscardisinstalled,port1isC6-T1(closesttoboard)andport0isC6-T2(towardsthetopofthecard).
Figure3.Backviewofthestand-alonesystemwith2RIO/HSLportsontheplanarand1buscardslot.Buscardisinstalled,port1isC6-T1(closesttoboard)andport0isC6-T2(towardsthetopofthecard).
Figure4.BackviewofthesystemwithnoRIO/HSLportsontheplanar,buthas2buscardslots(C6andC14).Whenbuscardisinstalledport1isCx-T1(closesttoboard)andport0isCx-T2(towardsthetopofthecard).
Figure5.Backviewofthestand-alonesystemwithnoRIO/HSLportsontheplanar,buthas2buscardslots(C6andC14).Whenbuscardisinstalledport1isCx-T1(closesttoboard)andport0isCx-T2(towardsthetopofthecard).
Figure6.Topviewofthesystem(includingserviceprocessorresetswitch)
Figure7.Memorymodulelocationsontheprocessorcard
Thefollowingtableprovideslocationcodesforpartsthatmakeuptheserver.
Attention:
Afterreplacinganypartonaserverorexpansionunit,performVerifyingtherepair.
Table1.FRUlocationsandfailingcomponents
Failingitemname
Symbolicfailingitemname
Physicallocationcode
IdentifyLED
Linktopartnumber
Failingitemremovalandreplacementprocedures
Systemunit
Un
Fans
PCIadaptersfan1
Un-A1
Yes
Partassemblydiagrams
Fans
PCIadaptersfan2
Un-A2
Yes
Partassemblydiagrams
Fans
Processorfan1
Un-A3
Yes
Partassemblydiagrams
Fans
Processorfan2
Un-A4
Yes
Partassemblydiagrams
Fans
Powersupplies
Powersupply1
PWRSPLY
Un-E1
Yes
51BA
Powersupply
Powersupply2
PWRSPLY
Un-E2
Yes
51BA
Powersupply
Backplanes
Systembackplane
∙SPCN
∙Cardenclosureorbackplane
∙Multi-adapterbridge(all)
∙Serviceprocessor
∙RIOHub/HSLNIC
∙RIO/HSLI/OBridge
∙RIO/HSLlink
∙Ethernetcontroller
∙USBcontroller(AIX®orLinux®only)
∙IDEbridge(AIXorLinuxonly)
∙SCSIcontroller
∙Logicoscillator
∙InfiniBandhostchanneladapter
HCA
HSL_LNK
MA_BRDG
MABRCFG
MASBUS
NODEPL
PIOCARD
PPCITWR
PRI_PCI
SI_PHB
SVCPROC
SIIOADP
SYSBKPL
STORIOA
TWRBKPL
TWRCARD
Un-P1
Yes
28EC
Systembackplane
SCSIcontroller0
Un-P1-T14
SCSIcontroller1
Un-P1-T15
IDEcontroller
Un-P1-T16
Time-of-daybattery
Un-P1-E1
Powerparts
Serviceprocessortime-of-daybattery
Diskdrive(1-4)backplane
Un-P2(logicallocationUn-P1-T14-L15-L0)
Yes
28F6
28F7
292C
292E
Diskdrivebackplane
Diskdrive(5-8)backplane
Un-P3(logicallocationUn-P1-T15-L15-L0)
Yes
28F6
28F7
292C
292E
Diskdrivebackplane
Passthrucard
ConnectstointernalSCSIbusses
Mediadrivebackplane
Un-P4
Yes
28D1
291E
Mediadeviceenclosure
Systembackplaneports
systemport1
Un-P1-T1
S1systemport(frontofcontrolpanel)
Un-P1-T1
systemport2
Un-P1-T2
SPCN0(upperconnector)
Un-P1-T3
SPCN1(lowerconnector)
Un-P1-T4
HMC1(upperconnector)
Un-P1-T5
HMC2(lowerconnector)
Un-P1-T6
USBport0(upperconnector)
Un-P1-T7
USBport1(lowerconnector)
Un-P1-T8
EthernetportA(0)
Un-P1-T9
EthernetportB
(1)
Un-P1-T10
RIO/HSLPort0,left
Un-P1-T11,notavailableon9133-55A
RIO/HSLPort1,right
Un-P1-T12,notavailableon9133-55A
Rackindicator
Un-P1-T13
Processorandprocessorregulator
Processorcard1
Un-P1-C9
Yes
26F0
26F1
5237
8312
Processorcard2
Un-P1-C8
Yes
26F0
26F1
5237
8312
Voltageregulator1.5VonProcessorcard2
Un-P1-C8-C9
Yes
Powerparts
Voltageregulatormodules
Voltageregulator2.5V/1.8VonProcessorcard2
Un-P1-C8-C10
Yes
Powerparts
Voltageregulatormodules
Voltageregulator1.5VonProcessorcard1
Un-P1-C9-C9
Yes
Powerparts
Voltageregulatormodules
Voltageregulator2.5V/1.8VonProcessorcard1
Un-P1-C9-C10
Yes
Powerparts
Voltageregulatormodules
Voltageregulator1.2VforProcessorcard2
Un-P1-C11
Yes
Powerparts
Voltageregulatormodules
Voltageregulator1.2VforProcessorcard1
Un-P1-C12
Yes
Powerparts
Voltageregulatormodules
VPDcard
Un-P1-C13
Systemparts
VPDcard
Adapters
PCIadapterinslot1
PIOCARD
MASBUS
SLOTERR
Un-P1-C1
Yes
Systemparts
PCIadapter
PCIadapterinslot2
PIOCARD
MASBUS
SLOTERR
Un-P1-C2
Yes
Systemparts
PCIadapter
PCIadapterinslot3
PIOCARD
MASBUS
SLOTERR
Un-P1-C3
Yes
Systemparts
PCIadapter
PCIadapterinslot4
PIOCARD
MASBUS
SLOTERR
Un-P1-C4
Yes
Systemparts
PCIadapter
PCIadapterinslot5
PIOCARD
MASBUS
SLOTERR
Un-P1-C5
Yes
Systemparts
PCIadapter
GXadaptercard
SIIOADP
SIADPCD
Un-P1-C6
Yes
1806
1807
RIO/HSLadaptercard
GXadaptercardport1(bottom)
Un-P1-C6-T1
Yes
RIO/HSLcablesconcurrent
GXadaptercardport0(top)
Un-P1-C6-T2
Yes
RIO/HSLcablesconcurrent
GXadaptercard
SIIOADP
SIADPCD
Un-P1-C14
Yes
1806
1807
RIO/HSLadaptercard
GXadaptercardport1(bottom)
Un-P1-C14-T1
Yes
RIO/HSLcablesconcurrent
GXadaptercardport0(top)
Un-P1-C14-T2
Yes
RIO/HSLcablesconcurrent
RAIDenablementcard
Un-P1-C7
Yes
5709
RAIDenablementcard
PCIbridgeset1
BRDGSET
BRDGST1
Un-P1
Un-P1-C1
Un-P1-C2
Replacethesystembackplaneandcardsusingtheremovalandreplacementprocedurescorrespondingtothelocationsindicated.
PCIbridgeset2
BRDGSET
BRDGST2
Un-P1
Un-P1-C4
Un-P1-C5
Replacethesystembackplaneandcardsusingtheremovalandreplacementprocedurescorrespondingtothelocationsindicated.
PCIbridgeset3
BRDGSET
BRDGST3
Un-P1
Un-P1-C3
Memorymodules
Memorymodule1
MEMDIMM
Un-P1-C8-C1
Yes
Memoryparts
Memorymodules
Memorymodule2
MEMDIMM
Un-P1-C8-C2
Yes
Memoryparts
Memorymodules
Memorymodule3
MEMDIMM
Un-P1-C8-C3
Yes
Memoryparts
Memorymodules
Memorymodule4
MEMDIMM
Un-P1-C8-C4
Yes
Memoryparts
Memorymodules
Memorymodule5
MEMDIMM
Un-P1-C8-C5
Yes
Memoryparts
Memorymodules
Memorymodule6
MEMDIMM
Un-P1-C8-C6
Yes
Memoryparts
Memorymodules
Memorymodule7
MEMDIMM
Un-P1-C8-C7
Yes
Memoryparts
Memorymodules
Memorymodule8
MEMDIMM
Un-P1-C8-C8
Yes
Memoryparts
Memorymodules
Memorymodule1
MEMDIMM
Un-P1-C9-C1
Yes
Memoryparts
Memorymodules
Memorymodule2
MEMDIMM
Un-P1-C9-C2
Yes
Memoryparts
Memorymodules
Memorymodule3
MEMDIMM
Un-P1-C9-C3
Yes
Memoryparts
Memorymodules
Memorymodule4
MEMDIMM
Un-P1-C9-C4
Yes
Memoryparts
Memorymodules
Memorymodule5
MEMDIMM
Un-P1-C9-C5
Yes
Memoryparts
Memorymodules
Memorymodule6
MEMDIMM
Un-P1-C9-C6
Yes
Memoryparts
Memorymodules
Memorymodule7
MEMDIMM
Un-P1-C9-C7
Yes
Memoryparts
Memorymodules
Memorymodule8
MEMDIMM
Un-P1-C9-C8
Yes
Memoryparts
Memorymodules
Devicephysicallocations
Diskdrive1
Un-P2-D1(logicallocationUn-P1-T14-L8-L0orUn-P1-Cn-Tn-L8-L01)
Yes
Diskunitparts
Diskdrive
Diskdrive2
Un-P2-D2(logicallocationUn-P1-T14-L5-L0orUn-P1-Cn-Tn-L5-L01)
Yes
Diskunitparts
Diskdrive
Diskdrive3
Un-P2-D3(logicallocationUn-P1-T14-L4-L0orUn-P1-Cn-Tn-L4-L01)
Yes
Diskunitparts
Diskdrive
Diskdrive4
Un-P2-D4(logicallocationUn-P1-T14-L3-L0orUn-P1-Cn-Tn-L3-L01)
Yes
Diskunitparts
Diskdrive
Diskdrive5
Un-P3-D1(logicallocationUn-P1-T15-L8-L0)
Yes
Diskunitparts
Diskdrive
Diskdrive6
Un-P3-D2(logicallocationUn-P1-T15-L5-L0)
Yes
Diskunitparts
Diskdrive
Diskdrive7
Un-P3-D3(logicallocationUn-P1-T15-L4-L0)
Yes
Diskunitparts
Diskdrive
Diskdrive8
Un-P3-D4(logicallocationUn-P1-T15-L3-L0)
Yes
Diskunitparts
Diskdrive
SCSIdevice
Un-P4-D1(logicallocationUn-P1-T14-L0-L0withRPApartitionandUn-P1-T14-L7-L0withSystemi®partition)
Removablemediadeviceparts
Mediadevice
IDEdevice1
Un-P4-D2(logicallocationUn-P1-T14-L1-L0withRPApartitionandUn-P1-T14-L6-L0withSystemipartition)
Removablemediadeviceparts
Mediadevice
IDEdevice2
Un-P4-D3
Removablemediadeviceparts
Mediadevice
1AlogicallocationcodewiththeformofUn-P1-Cn-Tn-Ln-LnindicatesthatthediskisattachedtoadiskcontrolleronaPCIadapter.CnidentifiesthecardslotofthePCIadapter.TnidentifiestheportonthePCIadapter.
Controlpanel
Controlpanel
Un-D1
28E5,250C
Controlpanelandsignalcable
Temperaturesensor
Un-D1
28E5seem
Controlpanelandsignalcable
Input/outputadapter(IOA)assignmentrulesfori5/OS®
Thefollowingtableprovidesinformationnecessarytoidentifytheinput/outputprocessor(IOP)towhichIOAsareassigned.TheleftcolumnindicatesthebridgesetinwhichIOAassignmentisallowed.UsetherightcolumntodeterminetheIOPtowhichanIOAisassigned.ThefirstpositioninthelistmustbeanIOP.TheremainingpositionsmightbeIOPsorIOAs.IOAsareassignedtothefirstIOP