开关电源黑盒测试规范
1.目的......................................................................................2
2.适用范围..................................................................................2
3.测试所用仪器与设备........................................................................2
4.测试基本原则及判定准则....................................................................2
4.1测试基本原则..........................................................................2
4.2不合格项目分类........................................................................2
5.测试内容和方法............................................................................2
5.1最大输入电流..........................................................................2
5.2交叉调节测试(交调测试).............................................................3
5.3电压调整率(源效应).................................................................3
5.4负载调整率(负载效应)................................................................3
5.5稳压精度...............................................................................4
5.6效率...................................................................................4
5.7最大空载功耗...........................................................................4
5.8输出纹波与噪声.........................................................................4
5.9容性负载特性...........................................................................6
5.10输入电压范围..........................................................................6
5.11启动冲击电流..........................................................................6
5.12动态响应..............................................................................7
5.13开关机过冲............................................................................7
5.14输出电压上升时间及下降时间............................................................8
5.15开机延时(启动延时).................................................................8
5.16关机延时(保持时间).................................................................9
5.17输入过压、欠压及其恢复................................................................9
5.18输出过压保护..........................................................................9
5.19输出限流保护.........................................................................10
5.20输出短路保护.........................................................................10
5.21过温保护.............................................................................10
5.22温度系数.............................................................................11
5.23工作频率.............................................................................11
5.24均流性能测试(对有均流电路的电源)..................................................11
5.25并机测试(对使用在1+1备份的定制电源)..............................................11
5.26绝缘强度.............................................................................12
5.27绝缘电阻.............................................................................13
5.28泄漏电流.............................................................................13
5.27接地电阻.............................................................................13
6环境试验...................................................................................13
6.1高、低温带电工作试验..................................................................14
7.引用和参考文件..............................................................................15
1.目的
为规范产品验证过程中电源的基本电气性能的测试方法,特制定本文件。
2.适用范围
本测试规范适用于验证中心对开关电源的验证测试。
3.测试所用仪器与设备
测试所需的设备均须为校验合格的设备,其精度必须高于测试所要求的精度至少一位。
4.测试基本原则及判定准则
4.1测试基本原则
4.1.1.以测试规范,产品规格书依据,以测试数据为准则,尽可能及早的发现设计缺陷。
4.1.2.测试工作不受开发工程师或市场人员及其他干扰,独立按测试流程进行。
4.1.3.测试过程中若发现问题比较严重且比较多,可直接将该产品退回给相应的开发工程师。
4.1.4.测试过程中,若样机有问题,但不影响测试的正常进行,则需测完样机的全部项目。
4.2不合格项目分类
4.2.1致命问题
●安规测试不合格;
●导致电源损坏的所有项目。
4.2.2严重问题
●技术指标未达到规格书的要求;
●抗干扰性指标未达到规格书要求。
4.2.3一般问题
●测试中指标的裕量不足。
4.2.4讨论问题
●研究性测试未合格项目;
●产品规格书中未界定的项目。
5.测试内容和方法
说明:
以下测试方法,如与国标或邮标等通用测试方法有出入的则以国标、邮标为准;测试项目以产品规格书规定的为准,产品规格书有要求的项目为必测项目,产品规格书未要求的项目可不测试;测试条件如果产品规格书有规定,则以产品规格书为准;当客户对测试项目和测试方法等有特别要求时,以客户的要求为准;输入全电压范围是指输入由最低输入电压到最高输入电压连续调节,但数据只需记录最低输入电压,额定输入电压,最高输入电压的情况。
输出全负载范围是指输出负载由最小负载到额定负载连续调节,但数据只需记录最小负载,半载,额定负载的情况。
高温低温分别指产品规格书中的工作温度的上限和下限。
测试输入电源的频率要求为最小输入电压时47Hz(当设备能力达不到47Hz时按设备能达到的最小频率输入)、最大输入电压时63Hz、额定高电压输入时为50Hz、额定低电压输入时为60Hz。
5.1最大输入电流
测试说明:
在电源正常工作电压范围内,流入电源的最大电流。
测试方框图:
图1
测试方法:
1.先如图1布置好测试电路。
2.在电源正常工作电压范围内,输入最低电压。
3.电源所带负载为额定负载。
4.读取电参数测量仪上输入电流的数值,此即为最大输入电流。
5.此项在高、低、常温均需测试。
判定标准:
最大输入电流超标:
严重问题
5.2交叉调节测试(交调测试)
测试说明:
在多路输出的电源中,当其中一路负载发生变化时,会影响其他各组的输出,此项测试即为衡量一
路输出负载变化时对另一路的影响。
测试方法:
1.如图1连接好测试电路。
2.输入电压为额定输入电压。
3.输出带载条件为,各路小载,半载及满载的相互组合。
4.记录下各种负载组合的下的输出电压。
5.再将记录的某路输出电压数值代入下列公式,即可算出该路输出的交叉调整率:
交叉调整率=(MAX|Vohalf-Vo|)/Vohalf×100%
Vohalf:
所有输出均带半载时,此路的输出电压值
Vo:
各种负载组合下该路的输出电压
6.此项在高、低、常温都需测试。
判定标准:
交叉调整率超标:
严重问题
5.3电压调整率(源效应)
测试说明:
输入电压变化对输出电压的影响程度。
在额定负载下,输入电压从最小值到最大值变化时,输出电
压与满载整定值的最大相对误差。
测试方法:
1.如图1连接好测试电路。
2.负载电流为额定值(满载电流)