Update on Bispectral Index monitoring.docx

《Update on Bispectral Index monitoring.docx》由会员分享,可在线阅读,更多相关《Update on Bispectral Index monitoring.docx(23页珍藏版)》请在冰豆网上搜索。

Update on Bispectral Index monitoring.docx

UpdateonBispectralIndexmonitoring

UpdateonBispectralIndexmonitoring

JayW.JohansenMD,PhD,1,,AssociateProfessorofClinicalAnesthesiology

EmoryUniversitySchoolofMedicine,DepartmentofAnesthesiology,GradyHealthSystem,49JesseHillJr.Drive,SE,Atlanta,Georgia30303,USA

Availableonline17March2006.

Since1997,bispectralindex(BIS;AspectMedicalSystemsInc.,Natick,MA)hasbeeninclinicalpracticeandawealthofexperimentalresearchhasaccumulatedonitsuse.Originally,thedevicewasapprovedonlyformonitoringhypnosisandhasnowreceivedanindicationforreducingtheincidenceofintraoperativeawarenessduringanesthesia.NumerousstudieshavedocumentedtheabilityofBIStoreduceintermediateoutcomessuchashypnoticdrugadministration,extubationtime,postoperativenauseaandshortenedrecoveryroomdischarge.Tworecentlarge-scaleoutcomestudiesusingBIS(onerandomizedcontrolledtrialandoneprospective,nonrandomizedhistoricalcohortstudy)identifiedanapproximately80%reductionintheincidenceofrecallafteranesthesia.BISprovidesclinicianswithuniqueinformationthatcanbeusedtotailorhypnoticdrugdosestoindividualpatientrequirements.BISdoesnotpredictmovementorhemodynamicresponsetostimulation,norwillitpredicttheexactmomentconsciousnessreturns.ThisreviewwillalsodiscussotherBISapplicationsincludinguseinpediatrics,intensivecareandforproceduralsedation.SomelimitationsexisttotheuseofBISanditisnotusefulforsomeindividualhypnoticagents(ketamine,dexmedetomidine,nitrousoxide,xenon,opioids).BIStechnologyismovingoutoftheoperatingroomandintodiverseenvironmentswhereconsciousanddeepsedationareprovided.Anesthesiologistsneedtobeactivelyinvolvedinpromotingpatientsafetyandhelpingtransitionthistechnologyintobroaderuse.

Keywords:

bispectralindex;awareness;recall;technologyassessment;sedation

ArticleOutline

Background

HypnotictitrationusingBIS

Researchupdate:

clinicaloutcomestudies

KnownlimitationsofBISmonitoring4.1Signalqualityandelectricalinterference

HypnoticsnoteffectivelymonitoredbyBIS

DiseaseprocesseslimitingBISmonitoring

OtherapplicationsofBISmonitoring

Pediatrics

Sedation:

monitoredanesthesiacareandintensivecare

Conscioussedation

Summary

References

Thereleaseofthebispectralindexmonitor(BIS,AspectMedicalSystemsInc.,Natick,MA)inOctober1996providedanesthesiologistswithareliablebrainfunctionmonitorthatallowedhypnotictitrationoverthecompleterangeofcorticalactivity.Numerouscomments,editorials,reviews1J.C.Drummond,Monitoringdepthofanesthesia:

withemphasisontheapplicationofthebispectralindexandthemiddlelatencyauditoryevokedresponsetothepreventionofrecall,Anesthesiology93(2000),pp.876–882.FullTextviaCrossRef|ViewRecordinScopus|CitedByinScopus(173)1,2and3andover550peer-reviewedpublicationsonBIShaveappearedoverthelast9years.InJanuary2004,BISreceivedanFDAapprovedindicationforreducingtheincidenceofintraoperativeawarenessduringgeneralanesthesia(510(k),#K030267)Recently,twostudies4and5,promptedtheJointCommissiononAccreditationofHealthcareOrganizations(JCAHO)topublishaSentinelEventAlert(October6,2004)onpatientawarenessunderanesthesia.TheAmericanSocietyofAnesthesiologists(ASA)hasrespondedbyconveningtheTaskForceonIntraoperativeAwarenessandisattemptingtodevelopaPracticeAdvisoryonBrainFunctionMonitoring.Neartheendof2004,approximately34%ofallhospitaloperatingroomshadaBISmonitor,78%ofteachinginstitutionsutilizedthemonitorandithadaworldwideinstallationbaseofover25 000units.ThepurposeofthischapteristoprovidesomebackgroundonBISandtodiscusstheclinicalimplicationsofrecentoutcomeresearchandregulatoryactivity.

Background

Alinkbetweenthemeasuredelectricalactivityofthecerebralcortexandelectroencephalogram(EEG)wasfirstsuggestedin1937.6DrRampilhasprovidedanexcellentreviewandadetaileddescriptionofthevariousapproachestoEEGsignalprocessing,includingBIS.7EEGderivativessuchasthepowerspectraledge,medianfrequency,zero-crossingfrequency,etc.havebeenextensivelyinvestigatedandfoundgenerallyinsensitive,nonspecific,ordependentonspecificdrugcombinationsandwerenotmonotonicallyrelatedtodrugeffectorclinicalresponse.2and7OtherchaptersinthisvolumediscussotherEEG-basedbrainfunctionmonitorssuchastheAuditoryEvokedPotentialandEntropy.

Bispectralanalysisisastatisticaltechniquethatallowsstudyofphenomenawithnonlinearcharactersuchassurfbeatsandwavebreaking.8BispectralanalysisrepresentsadifferentdescriptionoftheEEGinthatinterfrequencyphaserelationshipsaremea