2AirConditioningSystem

LessontwoAirConditioningSystem

Airconditioningforpeopleisthecontroloftemperature,humidity,airmovementandaircleanliness,heatradiationsometimes[e.g.bychilledceiling],normallywithmechanicalmeans,toachievehumanthermalcomfort. 

Airconditioningsystemscanbecategorizedaccordingtothemeansbywhichthecontrollablecoolingisaccomplishedintheconditionedspace.Theyarefurthersegregatedtoaccomplishspecificpurposesbyspecialequipmentarrangement.

 

Inselectingasuitableairconditioningsystemforaparticularapplication,considerationshouldalsogotothefollowing:

-

-Systemconstraints:

Coolingload,Zoningrequirements,Heatingandventilation

-ArchitecturalConstraints:

Sizeandappearanceofterminaldevices,acceptablenoiselevel,Spaceavailabletohouseequipmentanditslocationrelativetotheconditionedspace,acceptabilityofcomponentsobtrudingintotheconditionedspace

-FinancialConstraints:

Capitalcost,Operatingcost,Maintenancecost

 

Therearefourbasicsystemcategories:

1  Centralchilledwaterairconditioningsystems-AllAirSystems

1.1Singlezone

1.2Reheat

1.3VariableAirVolume

1.4DualDuct

1.5Multizone

2Centralchilledwaterairconditioningsystems-Air-andWaterSystems

2.1Induction

2.2FanCoil

2.3Two-pipe

2.4Three-pipe

3Centralchilledwaterairconditioningsystems-AllWaterSystems,includingcoolingtowerswhichcanalsobeappliedtosystems1,2above

3.1Fan-coilunits

3.2Centralchilledwaterairconditioningsystemwithfancoilsandotherdevices

3.3Watercoolingtower

4DirectexpansionSystems[i.e.directexpansionofrefrigerant,withoutthechilledwatercoolingmedium]

4.1Windowairconditioners

4.2UnitaryandRooftopAirConditioners

4.3Splittypeandpackageairconditioningsystems

4.4Heatpumps

1.Centralchilledwaterairconditioningsystems-AllAirSystems

Anall-airsystemprovidescompletesensibleandlatentcoolingcapacityinthecoldairsuppliedbythesystem.Heatingcanbeaccomplishedbythesameairstream,eitherinthecentralsystemorataparticularzone.All-airsystemscanbeclassifiedinto2categories:

-

 -Singleductsystems

-Dualductsystems

SystemAdvantages

◆Thecentralplantislocatedinunoccupiedareas,hencefacilitatingoperatingandmaintenance,noisecontrolandchoiceofsuitableequipment.

◆Nopiping,electricalwiringandfiltersarelocatedinsidetheconditionedspace.

◆Allowstheuseofthegreatestnumbersofpotentialcoolingseasonshousewithoutsideairinplaceofmechanicalrefrigeration.

◆Seasonalchangeoverissimpleandreadilyadaptabletoclimaticcontrol.

◆Givesawidechoiceofzonability,flexibility,andhumiditycontrolunderalloperatingconditions.

◆Heatrecoverysystemmaybereadilyincorporated.

◆Allowsgooddesignflexibilityforoptimumairdistribution,draftcontrol,andlocalrequirements.

◆Infringesleastonperimeterfloorspace.

◆Adaptstowinterhumidification.

 

SystemDisadvantages

◆Requiresadditionalductclearancewhichcanreducetheusablefloorspace.

◆Air-balancingisdifficultandrequiresgreatcare.

◆Accessibilitytoterminalsdemandsclosecooperationbetweenarchitectural,mechanicalandstructuralengineers.

 

Distributionsystemshaveanumberofimportantcomponents:

1.TheAirHandlingUnitisacabinetthatincludesorhousesthecentralfurnace,airconditioner,orheatpumpandtheplenumandblowerassemblythatforcesairthroughtheductwork.

2.TheSupplyDuctworkcarriesairfromtheairhandlertotheroomsinahouse.Typicallyeachroomhasatleastonesupplyductandlargerroomsmayhaveseveral.

3.TheReturnDuctworkcarriesairfromtheconditionedspacebacktotheairhandler.Mosthouseshaveonlyoneortwomainreturnductslocatedinacentralarea.

4.SupplyandReturnPlenumsareboxesmadeofductboard,metal,drywallorwoodthatdistributeairtoindividualductsorregisters.

5.TheDuctworkisabranchingnetworkofroundorrectangulartubesgenerallyconstructedofsheetmetal,fiberglassboard,oraflexibleplasticandwirecompositemateriallocatedwithinthewalls,floors,andceilings.Thethreemostcommontypesofductmaterialusedinhomeconstructionaremetal,fiberglassductboard,andflex-duct.

6.Flex-ductisinstalledbetweentheregisterandplenumbox,orplenumboxandairhandler,usuallyinasingle,continuouspiece.Whileflex-ducthasfewerseams,theinnerliningandouterinsulatedcoveringcantearorbepinchedclosed.Alsolongerflex-ductrunscanrestricttheflowofair;properdesignandinstallationisveryimportant.

7.Bothmetalandfiberglassductboardarerigidandinstalledinpieces.Fiberglassductboard,likeflex-duct,ismadeofaninsulationmaterial.Ductsarebuiltofsectionsoftheductboard.Theseamsintheductboardshouldbecarefullysealedwithmasticorhighqualityducttape.

8.Rectangularmetalduct,especiallythekindusedforplenumsandlargertrunkruns,isofteninsulatedontheinsidewithfiberglassductliner.Ifitisnotinsulatedontheinside,metalductsshouldbeinsulatedontheoutsideusingafiberglassbattwithanattachedmetalfoilvaporretarder.Theinsulationshouldbeatleasttwoinchesthick,andthevaporbarrierinstalledontheoutsideoftheinsulationfacingawayfromtheduct.

Theseamsintheinsulationareusuallystapledtogetheraroundtheductandthentaped.Alloftheseamsshouldbesealedbeforeinsulationisinstalled.Allreturnandsupplyductslocatedoutsidetheconditionedspace,inattics,crawlspaces,orbasements,forexample,shouldbesealedandinsulated.

9.DuctworkJointsjoinpiecesofductwork.

10.Elbowsaremanufacturedpiecesofductusedforturns.

11.Bootsconnectductworktoregisters.

12.RegistersandGrillesarethecoveringsforductopeningsintotheconditioned

space.

Thesecomponentswillbringabout:

-

 

-Heatbalance:

Theamountofheatextractedoutoftheairconditionedroom(bythecoolingsystem,exhaustairsystems,buildingleakage,mustbeequaltotheamountofheatgeneratedinsidetheroom(byhumanbeing,electricalappliances,etc.)andtransferredintotheroom(byconductionthroughthebuildingenvelope,radiationviatheglass,hotairleakageintotheroomthroughgapsinwindows,doors,freshairintroducedintotheroom,etc.)i.e.TotalkWgoingintoroom=TotalkWgoingoutoftheroom.

-Airbalance:

Themassflowrateoftheairgoingintotheroom=Themassflowrateofairgoingoutoftheroom.Freshaircomingintotheroom:

2.5l/sperperson,non-smoking,5l/sperpersonforsmokingaccommodation,goodindoorairquality(IAQ)isimportant.

 

1.1SingleZoneSystem

 

Theall-airsingle-zoneairconditioningsystemisthebasiccentralsystemwhichcansupplyaconstantairvolumeoravariableairvolumeatlow,mediumorhighpressure.Normally,theequipmentislocatedoutsidetheconditionedspacebutcanalsobeinstalledwithintheconditionedareaifconditionspermit.Typicalapplicationsinclude:

-

 

-Spacewithuniformloads

-Smallspacesrequiringprecisioncontrol

-Multiplesystemsforlargeareas

 

1.2ReheatSystem

 

Thereheatsystemisamodificationofthesingle-zonesystem.Itprovides:

-

-Zoneorspacecontrolforareasofunequalloading.

-Heatingorcoolingofperimeterareaswithdifferentexposures.

-Closecontrolforprocessorcomfortapplications.

Inthereheatsystem,heatisaddedasasecondaryprocesstoeitherpreconditionedprimaryairorrecirculatedroomair.Theheatingmediumcanbehotwater,steamorelectricity.

 

Advantages:

Closelycontrolsspaceconditions

Disadvantages:

Expensivetooperate

1.3VariableAirVolumeSystem

 Thevariableairvolumesystemcompensatesforvaryingcoolingloadsbyregulatingthevolumeofcoolingairsuppliedthroughasingleduct.

(a)SimpleVariableAirVolume(VAV)

SimpleVAVsystemstypicallycoolsonlyandhavenorequirementforsimultaneousheatingandcoolinginvariouszones.

 

(b)VariableAirVolume–Reheat

Itintegratesheatingatorneartheterminalunits.Itisappliedtosystemsrequiringfullheatingandcoolingflexibilityininteriorandexteriorzones.Heatingisturnedonwhentheairflowreachesapredeterminedminimum.

 

 Advantages

a)Whencombinedwithaperimeterheatingsystem,itoffersinexpensivetemperaturecontrolformultiplezoningandahighdegreeofsimultaneousheating-coolingflexibility.

b)Capitalcostislowersincediversitiesofloadsfromlights,occupancy,solarandequipmentofasmuchas30%arepermitted.

 

c)Virtuallyself-balancing.

d)Itiseasyandinexpensivetosubdivideintonewzonesandtohandleincreasedloadswithnewtenancyorusageifloaddoesnotexceedtheoriginaldesignsimultaneouspeak.

e)Nozoningisrequiredincentralequipment.

f)Loweroperatingcostbecause

Fansrunlonghoursatreducedvolume

Refrigeration,heatingandpumpingmatchesdiversityofloads

Unoccupiedareasmaybefullycut-off

g)Reducednoiselevelwhenthesystemisrunningatoff-peakloads.

h)Allowssimultaneousheatingandcoolingwithoutseasonalchangeover.

 

1.4DualDuctSystem

 

Thedual-ductsystememploystwoairductstosupplycoldairandwarmairtoamixingterminalunitwhichproportionsthecoldandwarmairinresponsetoathermostatlocatedintheconditionedspace.Thesystemiswellsuitedtoprovidetemperaturecontrolforindividualspacesorzones.

 

Advantages(inadditiontothosecommontoallairsystems)

●Systemswithterminalvolumeregulationareself-balancing.

●Zoningofcentralequipmentisnotrequired.

●Instanttemperatureresponseisach