1、英文版检验报告TEST REPORTIEC 60598-2-1 and/or EN 60598-2-1Part 2: Particular requirementsSection One Fixed general purpose luminairesReport Reference No. : Tested by (name+signature) : Witnessed by (name+signature) : Supervised by (name+signature) : Approved by (name+signature) : Date of issue :CB/CCA Test
2、ing Laboratory :Address :Testing location/ procedure :CBTL RMT SMT WMT TMP Testing location/ address :Applicants name :Address :Test specification:Standard : IEC60598-2-1:1979+A1:1987 used in conjunction with IEC60598-1:2003 EN60598-2-1:1979+A1:1987 used in conjunction with EN60598-1:2004Test proced
3、ure :CB / CCANon-standard test method.:N/ATest Report Form No. :IECEN60598_2_1ATRF Originator :Intertek Semko ABMaster TRF :Dated 2004-09Copyright 2004 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), Geneva, Switzerland. All rights reserved.This publication may b
4、e reproduced in whole or in part for non-commercial purposes as long as the IECEE is acknowledged as copyright owner and source of the material. IECEE takes no responsibility for and will not assume liability for damages resulting from the readers interpretation of the reproduced material due to its
5、 placement and context.Test item description :Trade Mark :Manufacturer :Model/Type reference :Address :Ratings :Copy of marking plateSummary of testing:Test item particulars :Possible test case verdicts:- test case does not apply to the test object :N/A- test object does meet the requirement :P(Pass
6、)- test object does not meet the requirement :F(Fail)Testing :Date of receipt of test item :Date (s) of performance of tests :General remarks:This report is not valid as a CB Test Report unless signed by an approved CB Testing Laboratory and appended to a CB Test Certificate issued by an NCB in acco
7、rdance with IECEE 02.This report is not valid as a CCA Test Report unless signed by an approved CCA Testing Laboratory and appended to a CCA Notification of a CCA Notification of Test Result issued by an NCB in accordance with a CCA Group Permanent Documents.The test results presented in this report
8、 relate only to the object tested.This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory.(see Enclosure #) refers to additional information appended to the report.(see appended table) refers to a table appended to the report.List of test e
9、quipment must be kept on file and available for review.Throughout this report a comma (point) is used as the decimal separator.In this report requirements valid for EN only are marked with (EN).General product information:1.2 (0)GENERAL TEST REQUIREMENTS1.2 (0.1)Information for luminaire design cons
10、ideredStandardYes / No 1.2 (0.3)More sections applicable :Yes / No 1.4 (2)CLASSIFICATION1.4 (2.2)Type of protection :Class 1.4 (2.3)Degree of protection :IP 1.4 (2.4)Luminaire only suitable for non-combustible surfaces :Yes / No Luminaire suitable for normally flammable surfaces :Yes / No Luminaire
11、suitable to be covered by insulating material :Yes / No 1.4 (2.5)Luminaire for normal use :Yes / No Luminaire for rough service :Yes / No 1.5 (3)MARKING1.5 (3.2)Mandatory markingsPosition of the markingFormat of symbols/text1.5 (3.3)Additional informationLanguage of instructions1.5 (3.3.1)Combinatio
12、n luminaires1.5 (3.3.2)Nominal frequency in Hz1.5 (3.3.3)Operating temperature1.5 (3.3.4)Symbol or warning notice1.5 (3.3.5)Wiring diagram1.5 (3.3.6)Special conditions1.5 (3.3.7)Metal halide lamp luminaire warning1.5 (3.3.8)Limitation for semi-luminaires1.5 (3.3.9)Power factor and supply current1.5
13、(3.3.10)Suitability for use indoors1.5 (3.3.11)Luminaires with remote control1.5 (3.3.12)Clip-mounted luminaire warning1.5 (3.3.13)Specifications of protective shields1.5 (3.3.14)Symbol for nature of supply1.5 (3.3.15)Rated current of socket outlet1.5 (3.3.16)Rough service luminaire1.5 (3.3.17)Mount
14、ing instruction for type Y, type Z and some type X attachments1.5 (3.3.18)Non-ordinary luminaires with PVC cable1.5 (3.3.101)Adequate warning on the package (EN)1.5 (3.4)Test with waterTest with hexaneLegible after testLabel attached1.6 (4)CONSTRUCTION1.6 (4.2)Components replaceable without difficul
15、ty1.6 (4.3)Wire ways smooth and free from sharp edges1.6 (4.4)Lampholders1.6 (4.4.1)Integral lampholder1.6 (4.4.2)Wiring connection1.6 (4.4.3)Lampholder for endtoend mounting1.6 (4.4.4)Positioning- pressure test (N) :- bending test (Nm) :1.6 (4.4.5)Peak pulse voltage1.6 (4.4.6)Centre contact1.6 (4.4
16、.7)Parts in rough service luminaires resistance to tracking1.6 (4.4.8)Lamp connectors1.6 (4.4.9)Caps and bases correctly used1.6 (4.5)Starter holdersStarter holder in luminaires other than class IIStarter holder class II construction1.6 (4.6)Terminal blocksTailsUnsecured blocks1.6 (4.7)Terminals and
17、 supply connections1.6 (4.7.1)Contact to metal parts1.6 (4.7.2)Test 8mm live conductorTest 8mm earth conductor1.6 (4.7.3)Terminals for supply conductors1.6 (4.7.3.1)Welded connections:- stranded or solid conductor- spot welding- welding between wires- Type Z attachment- mechanical test according to
18、15.8.2- electrical test according to 15.9- ageing test according to 15.9.2.3 and 15.9.2.41.6 (4.7.4)Terminals other than supply connection1.6 (4.7.5)Heat-resistant wiring/sleeves1.6 (4.7.6)Multi-pole plug- test at 30 N1.6 (4.8)Switches:- adequate rating- adequate fixing- polarized supply- compliance
19、 with 61058-1 for electronic switches1.6 (4.9)Insulating lining and sleeves1.6 (4.9.1)RetainmentMethod of fixing :1.6 (4.9.2)Insulated linings and sleevesa) & c) Insulation resistance and electric strengthb) Ageing test. Temperature (C) :1.6 (4.10)Insulation of ClassII luminaires1.6 (4.10.1)No conta
20、ct, mounting surface - accessible metal parts - wiring of basic insulation Safe installation fixed luminairesCapacitors and switchesInterference suppression capacitors according to IEC 60384-141.6 (4.10.2)Assembly gaps: not coincidental no straight access with test probe1.6 (4.10.3)Retainment of ins
21、ulation: fixed unable to be replaced; luminaire inoperative sleeves retained in position lining in lampholder1.6 (4.11)Electrical connections1.6 (4.11.1)Contact pressure1.6 (4.11.2)Screws: self-tapping screws threadcutting screws at least two self-tapping screws1.6 (4.11.3)Screw locking: spring wash
22、er rivets1.6 (4.11.4)Material of current-carrying parts1.6 (4.11.5)No contact to wood1.6 (4.11.6)Electro-mechanical contact systems1.6 (4.12)Mechanical connections and glands1.6 (4.12.1)Screws not made of soft metalScrews of insulating materialTorque test: torque (Nm); part :Torque test: torque (Nm)
23、; part :Torque test: torque (Nm); part :1.6 (4.12.2)Screws with diameter 3mm screwed into metal1.6 (4.12.4)Locked connections:- fixed arms; torque (Nm) :- lampholder; torque (Nm) :- push-button switches; torque 0,8 Nm :1.6 (4.12.5)Screwed glands; force (N) :1.6 (4.13)Mechanical strength1.6 (4.13.1)I
24、mpact tests: fragile parts; energy (Nm) : other parts; energy (Nm) :1) live parts2) linings3) protection4) covers1.6 (4.13.3)Straight test finger1.6 (4.13.4)Rough service luminaires- IP54 or highera) fixedb) hand-heldc) delivered with a standd) for temporary installations and suitable for mounting o
25、n a stand1.6 (4.13.6)Tumbling barrel1.6 (4.14)Suspensions and adjusting devices1.6 (4.14.1)Mechanical load:A) four times the weightB) torque 2,5NmC) bracket arm; bending moment (Nm) :D) load trackmounted luminairesE) clip-mounted luminaires, glass-shelve. Thickness (mm) :metal rod. Diameter (mm) :Fi
26、xed luminaire or independent control gear without fixing devices1.6 (4.14.2)Load to flexible cablesMass (kg) :Stress in conductors (N/mm) :Semi-luminaires mass (kg) :Semi-luminaires bending moment (Nm) :1.6 (4.14.3)Adjusting devices: flexing test; number of cycles : strands broken electric strength
27、test afterwards1.6 (4.14.4)Telescopic tubes: cords not fixed to tube; no strain on conductors1.6 (4.14.5)Guide pulleys1.6 (4.14.6)Strain on socket-outlets1.6 (4.15)Flammable materials: glowwire test 650 C spacing 30mm screen withstanding test of 13.3.1 screen dimensions no fiercely burning material thermal protection electronic circuits exempted1.6 (4.15.2)Luminaires made of thermoplastic material with lamp control geara) constructionb) temperature sensing controlc) surface temperature1.6 (4