1、压力释放阀说明书中英压 力 释 放 阀PRESSURE RELEASE VALVE使 用 说 明 书OPERATION INSTRUCTION明远电器设备SHENYANG MINGYUAN ELECTRIC EQUIPMENT CO., Ltd.本说明书适用于我公司生产的系列变压器用压力释放阀,阐述其用途、性能、规格、技术参数、使用与安装,供用户参考。The Operation Instruction is applicable to pressure release valve of a series of transformers manufactured by our company,
2、indicating its application, performances, specifications, technical parameters, usage and installation for uses reference. 1. 压力释放阀用途和性能压力释放阀适用于油浸式电力变压器、电力电容器与有载分接开关等,用来保护油箱。当油浸式变压器在运行中出现故障时,由于线圈过热,使一部分变压器油汽化,变压器油箱中压力迅速增加,这时压力释放阀在2ms迅速动作,释放压力,保护油箱不致变形或爆裂。油箱的压力再升高而达到开启压力时,压力释放阀应再次动作,直到油箱的压力降到正常值。由于压力
3、释放阀动作后能可靠关闭,油箱外的水和空气不能进入油箱,变压器部不会受大气污染。1.Application and performance Pressure release valves play avital role in the protection of oil-immersed electrical equipments, such as transformers, high voltage switch gears, capacitor and on load tap-changers, etc. This device can prevent the oil-immersed el
4、ectrical equipment from deformation or rupture. Should a fault occur in such electrical equipment, from deformation of rupture? Should a fault occurring in such electrical equipment, they are instantaneously vaporize the oil causing extremely rapid build-up of gaseous pressure? If mounting this type
5、 pressure release device on the oil-tank, when the pressure reaches to its opening pressure, it opens automatically within 2ms and relieves the pressure.2型号、规格与基本参数Type,specification and technical parameters 2.1 型号的含义 Meaning of typeY S F / 特殊环境代号(Special environment)带机械信号标“J”(“J”:mechanical signal)
6、带信号开关标“K”(“K”:electrical signal)两者都带标“KJ”(“KJ”:Both withsignal)喷油有效口径(Caliber of oil-gushing tube)mm开启压力(Opening pressure)kPa设计序号(Design serial number)阀(valve)释放(release)压力(pressure)注:特殊环境代号 note: special environment:TA: 干热带地区 dry tropicTH: 湿热带地区 humid tropicT: 干、湿热带地区 dry、humid tropic例:YSF16-55/130
7、KKJT开启压力为55kPa,喷油口径为130mm,带电信号、机械信号。适用于干、湿热带地区的压力释放阀。Example: YSF16-55/130KKJT in which, opening pressure is 55kPa, caliber of oil-gushing tube is130mm and flange erection, with electrical and mechanical signal and waterproof, use in dry、humid tropic。2.2 规格(见表1)Specifications(given in Table )表1 Tabl
8、e 喷油有效口径effective caliber(mm)开启压力opening pressure(Kpa)2015,25,35,5525508035,55,70,851302.3 基本参数(见表2)Basic technical data(given in Table )表2 单位:kPa Table unit:kPa开启压力opening pressure152535557085开启压力偏差deviation of openingpressure5关闭压力closing pressure813.51929.537.545.5密封压力seal pressure915213342513.安装尺
9、寸Installation dimensions3.1 法兰安装尺寸(见表3)Flange installation dimensions(given in Table )表 单位 mm Table unit : mm喷油有效口径caliber of oil-gushing tube255080130连接管径Internal diameter of connection tube4580130165安装法兰螺孔中心距center point distant of installation flange901301706、8型23510、12型240螺栓直径数量diameter of boltu
10、nitsM103M124M1266、8型M16612、16型M2083.2 螺纹安装尺寸(见表)Screw installation dimensions(given in Table )表 单位mm Table unit: mm有效喷油口径caliber of oil-gushing202550箱盖开孔hole in tank lid324067螺纹螺距thread stepM271.5M361.5M602.04. 压力释放阀的选用Selection of pressure release valve4.1 有效喷油口径的选择(见表)Selection of effective calibe
11、r of oil-gushing(see Table )表 Table 有效喷油口径(mm)effective caliber of oil-gushing20255080130油箱油重()total oil weight inoil-tank0.21.51.54.54.511.511.523若变压器油箱油总重量超过23吨,可按下式选择压力释放阀的数量:总油量(吨)/23130口径压力释放阀的数量 X=total oil weight(t)/23The effective caliber of oil-gushing may be chosen according to Table . If
12、the total oil weight in oil-tank exceeds 23t,the quantity of pressure release device to be used may be chosen according to following formula:锁帽Lock nut保护套 protective cover导油装置Oil equipment guide防雨帽Rain shield排油管Drain line标示杆Indicator阀盖Valvelid阀罩Valve cover接线盒Junction box螺钉Screw安装螺栓Mountingbolt阀座Valv
13、e seat放气阀Air vent valve密封胶垫Sealing gasket蝶阀Butterfly valve螺母Nuts变压器本体排油管Transformer bodydrain line图 一 Picture I (例如 E.g.: YSF16-55,70/130KKJT) 注:变压器运行之前务必请将锁帽卸下并将保护套带上!Notes: be sure to remove the lock nut and wear the protective coverbefore starting the transformer! ! !(图示为压力释放阀动作后的情形,动作前标示杆应在原位,防雨
14、帽应与阀盖接触)(The picture shows what the pressure release valve looks like when running, the indicator should be in situ and the rain shield should be in contact with the valve lid before running.)4.2 开启压力的选择Selection of opening pressure首先计算关闭压力的大小First calculate closing pressurePG=PJ+PE+PQPG: 关闭压力值(kPa)
15、Closing pressurePJ: 压力释放阀承受静压值(kPa)PJ=H r kPaStatic pressure stood by pressure release valve PJ=H r kPaH: 最高油面至压力释放阀底面距离m Distance between Max. Oil level land bottom of pressure release valvesr: 变压器油比重0.8510kg/m Proportion of oil for Transformer按上式求出关闭压力值后,可查表确定相应开启压力。After determining closing press
16、ure opening pressure can be chosen according to Table .PE附加的安全裕度压力(57kPa)Additional safety marginPQ:强油循环冷却附加安全裕度压力(57kPa)Forced oil circulation cooing additional safety margin 5. 压力释放阀的安装与使用Installation and operation5.1 压力释放阀一般安装在变压器油箱盖上或侧壁上。It should be mounted on the cover of side wall of the tran
17、sformer tank.5.2 对于法兰结构的压力释放阀,应配置法兰底座。The flange seat should be provided for mountingpressure release valves.5.2.1 将变压器本体上的安装法兰,蝶阀,压力释放阀的安装螺栓孔对齐(蝶阀两端的密封胶圈要放平放正)。Align the bolt holes of the flange the butterfly valve and the release valve on the transformer(the sealing rubber rings at both ends of th
18、e butterfly valve should be put correctly).5.2.2 将各安装螺纹拧紧。 Tighten the installation bolts.5.2.3 将压力释放阀喷口法兰、变压器本体排油管法兰与中间密封垫孔对齐。Align the flange of the release valve, the flange of the discharging oil pipe on the transformer and the middle sealing ring. 5.2.4 将连接螺栓拧紧。Tighten the connection bolts. 5.3
19、 螺纹连接的释放阀,在变压器箱盖上开孔尺寸见表4,然后将产品配备的阀托焊上即可。A connecting pressure release valve with screw, holes should be provided in the cover of transformer tank, thehole dimensions are in Table . The valve pad should be welded on the transformer.5.3.1 将压力释放阀阀托焊在变压器箱体开口上Weld the release valve seat to the open 锁帽hol
20、e of the transformer box. Lock nut 5.3.2 将套有密封胶圈的压力释放 保护套拧入阀托螺纹中,要注意密封胶圈的 protective cover安装质量,要平整不漏油。 防雨帽Turn the release valve with the sealing Rain shieldrubber ring into the screw of the valve seat. 标示杆Pay attention to the installation quality of Indicator the sealing rubber ring and there shoul
21、d be 阀盖Valve lidno oil leakage. 阀罩5.4 每台产品均配套有锁帽,但它仅是 Valve cover便于用户在做变压器整体密封试验 接线盒时使用,变压器运行前必须其取下。 Junction box否则在变压器出现故障时,压力释放 螺钉 阀不动作,将引起严重后果。 ScrewAll of the products equipped with lock nut, 阀座but when seal test of the transformer, Valve seatthe lock should be in its place, when密封胶垫transformer
22、put into use, it should be Sealing gaskettaken away. Otherwise the release valve 阀托will not act when the transformer takes place Valve caretrouble,which will cause serious result.图 二 Picture II (例如 E.g.: YSF8-35,55/50KJT)5.5请注意:取下锁帽后必须确认防雨帽是否完好地安装在标示杆上,并将保护套带上,否则下雨时雨水浸入释放阀,将引起电器部分损坏。Note:After the l
23、ock nut is taken off, make sure the rain shield be installed well andwear the protective cover,otherwise rain will flow into the release valve and cause the electric equipment damage.5.6安装有16型压力释放阀的变压器,灌油时,务必请将放气阀打开!Be sure to open the Air vent valve! When the transformer which Installated withpress
24、ure relief valvefilling grease,5.7 信号开关接点容量应符合表6规定。Contactor power of signal switch should comply with the valves in Table .表6 Table电压种类kind of voltagesupply电压Vvoltage电阻负载AResistanceload感性负载Ainductance load交流AC22053(cos=0.4)直流DC0.30.05(T=7ms)6. 到货验收注意事项与故障处理方法 Arrival acceptance notice and fault tre
25、atment6.1 检查运输过程中压力释放阀是否有破损 Check whether there is damage during transport6.2 文件是否丢失Whether the files are missing 6.3 螺纹安装的释放阀阀座是否丢失Whether the pressure releasevalve seat for screw installation is missing 6.4 压力释放阀不动作,检查锁帽是否拿掉 Pressure relief valve does not move, check whether the lock nut is remove
26、d6.5 压力释放阀动作后没有信号输出,应检查接线盒与其线路是否正确连接 After the pressure release valve movements no signal output, should check the wiring box, whether the wiring is connected firmly。7. 接线原理图(principle of connect electric wiring)11:公共接点(public contact)12:接点(public of)14: 接点(public of)11,12通:正常(normal)11,14通:被保护装置出现故
27、障(breakdown of by protection apparatus)21:公共接点(public contact)22:接点(public of)24: 接点(public of)21,22通:正常(normal)21,24通:被保护装置出现故障(breakdown of by protection apparatus)8. 订货须知Order notice 应注明产品的型号、规格、数量与开关电缆线长度。也可根据用户需要特殊设计制造。The type, specification, unit, cable length of switch, should be remarked. O
28、r the products may be specially designed and according with actual customers need.通信地址:Communication Address:明远电器设备SHENYANG MINGYUAN ELECTRIC EQUIPMENT CO., Ltd.地 址: 市河区凌云街上木厂5号Address: No. 5, Shangmuchang, Street Lingyu, District Dongling, Shenyang电 话: 0 2Telephone: 0 2邮 编: 110043Postcode: 110043传 真:1Fax:1联系人: 蕊Feng Rui 手机Mobile phone:Connector: 敏Li Min 手机Mobile phone:明远Feng Mingyuan 手机Mobile phone:
copyright@ 2008-2022 冰豆网网站版权所有