1、How to install InTouch Server AppplicationHow to install: InTouch Application Server the first time.Warning: Use administrator logon.Dont forget to define screen area as 1280 by 1024 pixels.Go to the C:WINNTsystem32driversetc directory.Select hosts file,Right click - open with “Notepad”.Enter addres
2、s “192.168.1.50” and name ”EJ01”,Enter address “192.168.1.51” and name ”LJ01”,Enter address “192.168.1.52” and name ”CJ01”,Enter address “192.168.1.53” and name ”CJ02”,Enter address “192.168.1.54” and name ”CJ03”,Enter address “192.168.1.55” and name ”LJ02”,Enter address “192.168.1.56” and name ”XJ0
3、1”,File menu - Save,File menu - Exit.Be careful, before continuing, be sure that:- ping EJ01 is OK (HPC),- ping LJ01 is OK (HPC),- ping CJ01 is OK (HPC),- ping CJ02 is OK (HPC),- ping CJ03 is OK (HPC),- ping LJ02 is OK (HPC),- ping XJ01 is OK (HPC),- ping THAPL_PC1 is OK (client PC),- ping THAPL_PC2
4、 is OK (client PC),- ping THAPL_PC3 is OK (client PC),- ping THAPL_PC4 is OK (client PC),- ping THAPL_PC5 is OK (client PC),- ping THAPL_PC6 is OK (client PC Skin),- ping THAPL_PC7 is OK (development PC).Go to the D:TISCO_HAPL directory.Select maj_serveur.cmd file,Right click - Create shortcut on de
5、sktop,Double click on “Shortcut to maj_serveur.cmd” to update application server.Press any key to exit window.Starting HPCSRV the first time.Double click on “Shortcut to HPCSRV” to start HPCSRV.File menu - Import from HMISelect D:TISCO_HAPLInTouch_Server directory,Select DB.CSV file, and click on “O
6、pen” button.Select device “CJ01”,Right click - Properties,Enter IP Address “192.168.1.52”, and click on “OK” button.Select group “CENT”,Right click - Properties.Enter Update period (ms): “500”,Select Protocol: “Resource DB”,Click on “From Flash” button,Click on “OK” button. If warning message click
7、on “Yes” button to take new value in account.Select group “CENTD”,Right click - Properties.Enter Update period (ms): “1000”,Select Protocol: “FUFA”,Click on “Yes” button to define a DEF segment,Enter Linked to: “CENT”,Click on “From Flash” button,Click on “OK” button. If warning message click on “Ye
8、s” button to take new value in account.Select group “CENTF ”,Right click - Properties.Enter Update period (ms): “1000”,Select Protocol: “FUFA”,Click on “NO” button,Enter Linked to: “CENT”Click on “From Flash” button,Click on “OK” button.Select device “CJ02”,Right click - Properties,Enter IP Address
9、“192.168.1.53”, and click on “OK” button.Select group “SKIN”,Right click - Properties.Enter Update period (ms): “500”,Select Protocol: “Resource DB”,Click on “From Flash” button,Click on “OK” button. If warning message click on “Yes” button to take new value in account.Select group “SKIND”,Right cli
10、ck - Properties.Enter Update period (ms): “1000”,Select Protocol: “FUFA”,Click on “Yes” button to define a DEF segment,Enter Linked to: “SKIN”,Click on “From Flash” button,Click on “OK” button. If warning message click on “Yes” button to take new value in account.Select group “SKINF”,Right click - P
11、roperties.Enter Update period (ms): “1000”,Select Protocol: “FUFA”,Click on “NO” button,Enter Linked to: “SKIN”Click on “From Flash” button,Click on “OK” button.Select device “CJ03”,Right click - Properties,Enter IP Address “192.168.1.54”, and click on “OK” button.Select group “PICK”,Right click - P
12、roperties.Enter Update period (ms): “500”,Select Protocol: “Resource DB”,Click on “From Flash” button,Click on “OK” button. If warning message click on “Yes” button to take new value in account.Select group “PICKD”,Right click - Properties.Enter Update period (ms): “1000”,Select Protocol: “FUFA”,Cli
13、ck on “Yes” button to define a DEF segment,Enter Linked to: “PICK”,Click on “From Flash” button,Click on “OK” button. If warning message click on “Yes” button to take new value in account.Select group “PICKF”,Right click - Properties.Enter Update period (ms): “1000”,Select Protocol: “FUFA”,Click on
14、“NO” button,Enter Linked to: “PICK”Click on “From Flash” button,Click on “OK” button.Select device “EJ01”,Right click - Properties,Enter IP Address “192.168.1.50”, and click on “OK” button.Select group “ENT”,Right click - Properties.Enter Update period (ms): “500”,Select Protocol: “Resource DB”,Clic
15、k on “From Flash” button,Click on “OK” button. If warning message click on “Yes” button to take new value in account.Select group “ENTD”,Right click - Properties.Enter Update period (ms): “1000”,Select Protocol: “FUFA”,Click on “Yes” button to define a DEF segment,Enter Linked to: “ENT”,Click on “Fr
16、om Flash” button,Click on “OK” button. If warning message click on “Yes” button to take new value in account.Select group “ENTF”,Right click - Properties.Enter Update period (ms): “1000”,Select Protocol: “FUFA”,Click on “NO” button,Enter Linked to: “ENT”Click on “From Flash” button,Click on “OK” but
17、ton.Select device “LJ01”,Right click - Properties,Enter IP Address “192.168.1.51”, and click on “OK” button.Select group “AUXI”,Right click - Properties.Enter Update period (ms): “500”,Select Protocol: “Resource DB”,Click on “From Flash” button,Click on “OK” button. If warning message click on “Yes”
18、 button to take new value in account.Select group “AUXID”,Right click - Properties.Enter Update period (ms): “1000”,Select Protocol: “FUFA”,Click on “Yes” button to define a DEF segment,Enter Linked to: “AUXI”,Click on “From Flash” button,Click on “OK” button. If warning message click on “Yes” butto
19、n to take new value in account.Select group “AUXIF”,Right click - Properties.Enter Update period (ms): “1000”,Select Protocol: “FUFA”,Click on “NO” button,Enter Linked to: “AUXI”Click on “From Flash” button,Click on “OK” button.Select device “LJ02”,Right click - Properties,Enter IP Address “192.168.
20、1.55”, and click on “OK” button.Select group “TK”,Right click - Properties.Enter Update period (ms): “500”,Select Protocol: “Resource DB”,Click on “From Flash” button,Click on “OK” button. If warning message click on “Yes” button to take new value in account.Select group “TKD”,Right click - Properti
21、es.Enter Update period (ms): “1000”,Select Protocol: “FUFA”,Click on “Yes” button to define a DEF segment,Enter Linked to: “TK”,Click on “From Flash” button,Click on “OK” button. If warning message click on “Yes” button to take new value in account.Select device “XJ01”,Right click - Properties,Enter
22、 IP Address “192.168.1.56”, and click on “OK” button.Select group “EXT”,Right click - Properties.Enter Update period (ms): “500”,Select Protocol: “Resource DB”,Click on “From Flash” button,Click on “OK” button. If warning message click on “Yes” button to take new value in account.Select group “EXTD”
23、,Right click - Properties.Enter Update period (ms): “1000”,Select Protocol: “FUFA”,Click on “Yes” button to define a DEF segment,Enter Linked to: “EXT”,Click on “From Flash” button,Click on “OK” button. If warning message click on “Yes” button to take new value in account.Select group “EXTF”,Right c
24、lick - Properties.Enter Update period (ms): “1000”,Select Protocol: “FUFA”,Click on “NO” button,Enter Linked to: “EXT”Click on “From Flash” button,Click on “OK” button. If warning message click on “Yes” button to take new value in account.File menu - Save.File menu - Export to HMIEnter File name: Po
25、urOpcLink, and click on “Open” file.Starting OPCLINK the first time. Double click on “Shortcut to OPClink” to start OPCLink.File menu - Open.Select “D:TISCO_HAPLHpcsrvexportPourOpcLink.cfg” file and click on “Open” button.Starting INTOUCH the first time.Double click on “Shortcut to INTOUCH” to start
26、 InTouch.Click on “Next” button.Select directory “D:TISCO_HAPLInTouch_Server” by browsing, and click on “OK” button.Click on “Finish” button.Select application name “Tisco HAPL Server”, and click on “viewer” to start intouch.Starting LOGGER HISTORIC the first time.Select “Start - Programs - Wonderwa
27、re - InTouch - Alarm DB Logger Manager”.Click on “Setting” button.Select Server Name “(local)”,Enter User Name “sa” without Password,Select “Detailed”, and click on “Create” button.Click on “Yes” button.Click on “OK” button.Click on “Test Connection” button.Click on “OK” button if success connection
28、.Click on “Next” button.Enter From Priority “1” To Priority “998”, and click on “Next” button.By default everything is OK, and click on “Finish” button.Click on “Start” button.Starting PURGE HISTORIC the first time.Select “Start - Programs - Wonderware - InTouch - Alarm DB Purge-Archive”.Select “Dat
29、abase” item.Select Server Name “(local)”,Enter User Name “sa” without Password, and click on “Test Connection” button.Click on “OK” button.Click on “Apply” button, and select “General” item.Select “Detailed Mode”, “8” Days Online,Enter Archive Folder Path “D:TISCO_HAPLHistoryArchives” by browsing,En
30、ter Log File Path “D:TISCO_HAPLHistoryLogFiles” by browsing,Click on “Apply” button, and select “Purge/Archive” item.Select “Daily”, Time “00:00”,Click on “Apply” button.Click on “Test Now” to validate configuration.Click on “Activate” button to start database purge.WARNING: Never close this window. You can only minimize window.Go to C:WINNT.Select win.ini,Right click - Open With- Notepad.Insert in InTouch area: AlarmDBPurgeArchiveActivated=1File menu - Exi
copyright@ 2008-2022 冰豆网网站版权所有