1、弯矩设计值M(=Mpl2)/KNm边跨跨中1/141/1412.62.3052=4.71B支座 1/111/112.3052=5.99离端第二跨跨中1/161/162.2252=3.84C支座2.2252=4.38中间跨跨中1/161/162.2252=3.843.配筋 b=1000 ,h=100 ,s=(15+5)=20 ,h0=(100-20) =80 ,fc=11.9N/2 ,ft=1.27 N/2 , fy=300 N/2。M/ (KNm)s=M/1fcbh02AS(=1fcbh0/ fy)实配钢筋4.710.0620.0652068 200,2525.990.0790.0812578
2、 200,3023.840.0500.0521658 200,2014.380.0580.0611943.840.0510.0531683.840.80.040127表 中值均小于0.35符合塑性内力重分布的条件。As/(bh)= 201/(1000100)=0.201%min =0.002。四、次梁计算b450,按塑性内力重分布方法计算内力。结构尺寸和计算简图简图。由板传来的永久荷载 4 .0KN/m2.5m=10.0 KN次梁自重 25KN/m0.2m(0.45-0.1)m=1.75 KN次梁抹灰 25KN/m(0.45-0.1)m2=0.35 KN永久荷载标准值 gk =12.1 KN可
3、变荷载标准值 qk=6 .0KN/m2.5m=15 KN荷载标准值 p=1.212.1 KNm +1.315 KNm =34.02 KN2. 内力主梁(ZL)截面 bh=30050 边跨 净跨度ln1=(6300-150-120)=6030计算跨度l01=(6030+250/2)=6155中间跨 净跨度ln2=(6300-300)=6000 计算跨度l02=6000跨度差 (6155-6000)/6000=2.6%10%,可按等跨连续梁查表计算。弯矩设计值计算列表如表所列。 弯矩设计值计算列表弯矩设计值M(=Mpl02)/(KN边跨跨内 1/1134.026.1552=117.16-1/11
4、-1/116.1552=-117.16离端第二跨跨内6.02=76.556.02=87.48中间跨跨内-1/16-1/166.02=-76.55 剪力设计值计算列表剪力系数v剪力设计值M(=vpln)/kN边支座A0.500.506.155=104.7B支座左0.550.556.155=115.17B支座右6.0=112.27C支座左、右3. 配筋(1) 正截面弯矩承载力计算b=250 ,h=450,s=(25+10)=35,h0=(450-35)=415,hf=100翼缘计算宽度:边跨bf=6155/3=2052b+sn=2500中跨bf=6000/3=2000min =0.2% 。(2)斜
5、截面弯矩承载力计算 b=250,h0=415, fyv=210 N/2,则 0.25fcbho=308.7KN115.17KN截面尺寸满足要求。1.1 ftbho=131.8KN 。箍筋采用双肢6 ,Asv1=28.32 。箍筋配筋表 V/KNV/ ftbho 箍筋104.70.621.0构造配置8 150115.170.82离端第二跨跨跨内112.270.85 0.85 8 150实际箍筋间距S=150sv,min=0.24ftfyv=0.145% 满足构造要求。五、主梁计算750,按弹性方法计算内力。主梁可按铰支承在柱顶的连续梁。结构尺寸和计算简图如图 所示。1. 荷载 由次梁传来的永久荷
6、载 12.68 KNm 6.3m=79.88 kN 主梁自重 25 KN/m0.3m(0.75-0.1)m2.5m=12.19 kN 主梁抹灰 25 KN/m2.5m2=1.63 kN 永久荷载标准值 GK=93.7 kN 可变荷载标准值 Qk=15 KNm6.3m =94.5 kN永久荷载设计值 G=1.293.7 kN =112.44 kN 可变荷载设计值 Q=1.394.5 KNm =122.85 kN 计算跨度: 边跨 净跨度ln1=(7500-120-250)=7130 计算跨度l01=7130 中间跨 净跨度ln2=(7500-500)=7000 计算跨度l02=7000 l01与
7、l02相近,可按等跨连续梁计算,取l0=7000mm 。查附录E附表E-2,得内力系数k列于表 中。内力计算表项次荷载简图弯矩M/ (KN剪力V/kNA支座kM1M2MBM3M4VAVBlVAr0.2440.155-0.2670.0670.733-1.2671.000192.0122.0-210.252.782.4-142.5112.440.289-0.1330.866-1.1340 248.5209.8-114.4106.4-139.3-0.044-0.0890.200-37.8-76.5172.0-16.3122.850.125-0.3110.0960.1700.689-1.3111.22
8、2196.9107.5-267.482.6146.284.6-116.1150.1-0.030-0.0590.778-25.8-50.7-111.6-10.995.6 内+440.5333.8-324.6-61.7188.8-281.8.力+154.245.5224.766.1-158.8235.29组+397.9229.5-477.6135.3198.9167.0-208.6262.54合+166.271.3-285.771.5-103.4208.043. 内力包括图内力包括图如图所示:4.配筋:(1)正截面受弯承载力计算 b=300 ,h=750 ,s =35 ,h0=(750-35)=7
9、15,hf=100 翼缘宽度 bf=7500/3=2500min =0.002(2)斜截面受剪承载力计算b=300, h0=715, fyv=210 N /0.25fcbho=638.1KN281.8KN截面尺寸满足要求 。1.2 ftbho=272.4KN 。箍筋采用双肢8,Asv1=50.32实配箍筋Vu=0.7ftbho+1.25fyvnAsv1ho/s0.6931.08 200285.1KNV281.81.035 1.0计算配置0.9641.08200实际箍筋间距S=2005.与次梁相交处附加横向钢筋面积次梁传来的集中力F=1.279.88 KN +1.394.5 KN =218.7K
10、N采用双肢8箍筋,Asv1=50.32,需配置的附加横向钢筋总面积Asv=F/(fysin)=1226 箍筋个数m=1226/(250.3)=12,应配置12个,次梁两侧各6个 。6.钢筋布置(1)弯起钢筋的弯起点距该钢筋强度的充分利用点大于h0/2.前一排钢筋弯起点至后一排钢筋弯终点的距离小于Smax。(2)B支座负弯矩纵向钢筋的截断点位置V0.7ftbho,钢筋的延伸长度从按正截面受弯承载力计算不需要的截面伸出不应小于h0且不小于20d,同时,从强度充分利用点伸出的长度应不小于1.2(la+ h0)。(3)跨内正弯矩纵向钢筋伸入支座的长度las12d。(4)支座A处按构造要求配置的负弯矩纵向钢筋面积不应小于1/4跨内截面纵向钢筋面积,配置212+122,As=606222812/4=570.252 。
copyright@ 2008-2022 冰豆网网站版权所有
经营许可证编号:鄂ICP备2022015515号-1