1、17. #/opt/MegaRAID/MegaCli/MegaCli64-cfgdsply-aALL 【显示Raid卡型号,Raid设置,Disk相关信息】18. 3.磁带状态的变化,从拔盘,到插盘的过程中。19. Device|Normal|Damage|Rebuild|Normal20. Virtual Drive|Optimal|Degraded|Degraded|Optimal21. Physical Drive|Online|Failed Unconfigured|Rebuild|Online22. 4.查看磁盘缓存策略23. #/opt/MegaRAID/MegaCli/MegaC
2、li64-LDGetProp-Cache-L0-a024. or25. #/opt/MegaRAID/MegaCli/MegaCli64-L126. or27. #/opt/MegaRAID/MegaCli/MegaCli6428. ro29. #/opt/MegaRAID/MegaCli/MegaCli64-aALL30. ro31. #/opt/MegaRAID/MegaCli/MegaCli64-DskCache32. 5.设置磁盘缓存策略33. 缓存策略解释:34. 35. WT(Write through36. WB(Write back)37. NORA(No read ahead
3、)38. RA(Read ahead)39. ADRA(Adaptive read ahead)40. Cached41. Direct42. 例子:43. #/opt/MegaRAID/MegaCli/MegaCli64-LDSetProp WT|WB|NORA|RA|ADRA44. or45. #/opt/MegaRAID/MegaCli/MegaCli64-LDSetProp-Cached|-Direct46. or47. enable/disable disk cache48. #/opt/MegaRAID/MegaCli/MegaCli64-EnDskCache|-DisDskCac
4、he49. 6.创建一个 raid5 阵列,由物理盘 2,3,4 构成,该阵列的热备盘是物理盘 550. #/opt/MegaRAID/MegaCli/MegaCli64-CfgLdAdd-r51:2,1:3,1:4WB Direct-Hsp1:551. 7.创建阵列,不指定热备52. #/opt/MegaRAID/MegaCli/MegaCli6453. 8.删除阵列54. #/opt/MegaRAID/MegaCli/MegaCli64-CfgLdDel55. 9.在线添加磁盘56. #/opt/MegaRAID/MegaCli/MegaCli64-LDRecon-Start-Add-Ph
5、ysDrv1:57. 10.阵列创建完后,会有一个初始化同步块的过程,可以看看其进度。58. #/opt/MegaRAID/MegaCli/MegaCli64-LDInit-ShowProg59. 或者以动态可视化文字界面显示60. #/opt/MegaRAID/MegaCli/MegaCli64-ProgDsply61. 11.查看阵列后台初始化进度62. #/opt/MegaRAID/MegaCli/MegaCli64-LDBI63. 或者以动态可视化文字界面显示64. #/opt/MegaRAID/MegaCli/MegaCli6465. 12.指定第 5 块盘作为全局热备66. #/o
6、pt/MegaRAID/MegaCli/MegaCli64-PDHSP-Set-EnclAffinity-nonRevertible67. 13.指定为某个阵列的专用热备68. #/opt/MegaRAID/MegaCli/MegaCli64-Dedicated-Array169. 14.删除全局热备70. #/opt/MegaRAID/MegaCli/MegaCli64-Rmv71. 15.将某块物理盘下线/上线72. #/opt/MegaRAID/MegaCli/MegaCli64-PDOffline-PhysDrv73. #/opt/MegaRAID/MegaCli/MegaCli64-
7、PDOnline74. 16.查看物理磁盘重建进度75. #/opt/MegaRAID/MegaCli/MegaCli64-PDRbld76. 或者以动态可视化文字界面显示77. #/opt/MegaRAID/MegaCli/MegaCli6478. 79. 磁带状态的变化,从拔盘,到插盘的过程中:80. Device81. Virtual Drive82. Physical Drive83. 1、查看RAID级别84. 85. 2、查看RAID卡信息,主要输出RAID卡的一些配置信息86. 87. 88. RAID Level : Primary-1, Secondary-0, RAID L
8、evel Qualifier-0Size : 1.086 TBState : OptimalStrip Size : 128 KBNumber Of Drives per span:4 /表示每4个物理盘做成一个RAID1盘组Span Depth : 2 /表示共2个RAID1盘组做成了RAID1089. 90. 3、查看所有硬盘的信息91. /opt/MegaCli64-pdlistaALL92. 93. 4、查看当前raid缓存状态,raid缓存状态设置为wb的话要注意电池放电事宜,设置电池放电模式为自动学习模式94. /opt/MegaRAID/MegaCli/MegaCli64 -ld
9、getprop -dskcache -lall -aall95. 96. 5、raid电池设置相关97. 查看电池状态信息(DisplayBBUStatusInformation)MegaCli-aN|-a0,1,2|-aALL98. 查看电池容量(DisplayCapacity99. 查看电池设计参数(DisplayDesignParameters)100. 查看电池属性(DisplayCurrentProperties)101. 设置电池为学习模式为循环模式(StartLearningCycle)DescriptionStartsthelearningcycleonBBU.Noparame
10、terisneededforthisoption.-BbuLearn102. 设置磁盘的缓存模式和访问方式(ChangeVirtualDiskCacheandAccessAllowsyoutochangefollowingvirtualdiskparameters:-WT(Writethrough),WBback):Selectswritepolicy.-NORA(Noreadahead),RA(ReadADRA(Adaptiveahead):-Cached,-Direct:cache-RW,-RO,Blocked:access-EnDskCache:Enablescache.-DisDskC
11、ache:DisablesWT|WB|NORA|RAADRA|-Cached|Direct|-RW|RO|Blocked-Namestring-EnDskCache|DisDskCacheLx-L0,1,2|-Lall103. 显示磁盘缓存和访问方式(Display-Access-Name-Lx|-L0,1,2|Displayspoliciesofdisk(s):-Cache,Direct:-Access,-DskCache:physical104. 105. Megaraid 必知必会 使用LSI的megaraid可以对raid进行有效监控。别的厂商比如HP,IBM也有自己的raid API
12、MegaCli -ldinfo -lall -aall查询raid级别,磁盘数量,容量,条带大小。MegaCli -cfgdsply -aALL |grep Policy查询控制器cache策略MegaCli -LDSetProp WB -L0 -a0设置write back功能MegaCli -LDSetProp CachedBadBBU -L0 -a0设置即使电池坏了还是保持WB功能MegaCli -AdpBbuCmd -BbuLearn a0手动充电MegaCli -FwTermLog -Dsply -aALL查询日志显示适配器个数: MegaCli -adpCount显示所有适配器信息
13、: MegaCli -AdpAllInfo -aAllCritical Disks : 0Failed Disks :显示所有逻辑磁盘组信息: MegaCli -LDInfo -LALL -aAll显示所有的物理信息: MegaCli -PDList -aAllMedia Error Count: 0Other Error Count:查看充电状态: MegaCli -AdpBbuCmd -GetBbuStatus -aALLLearn Cycle Requested : NoFully Charged : Yes显示BBU(后备电池)状态信息:显示BBU容量信息: MegaCli -AdpB
14、buCmd -GetBbuCapacityInfo -aALL显示BBU设计参数: MegaCli -AdpBbuCmd -GetBbuDesignInfo -aALL显示当前BBU属性: MegaCli -AdpBbuCmd -GetBbuProperties -aALL显示Raid卡型号,Raid设置,Disk相关信息: MegaCli -cfgdsply -aALL查看Cache 策略设置: MegaCli -cfgdsply -aALL |grep -i PolicyCurrent Cache Policy: WriteBack, ReadAheadNone, Direct, Writ
15、e Cache OK if Bad BBU查看充电进度百分比: MegaCli -AdpBbuCmd -GetBbuStatus -aALL各种设备和磁盘的不同状态:Device |Normal|Damage|Rebuild|NormalVirtual Drive |Optimal|Degraded|Degraded|OptimalPhysical Drive |Online|Failed Unconfigured|Rebuild|Online106. 6、通过脚本检测RAID磁盘状态107. Linux下脚本108. #!/bin/bash109. #checkstatus110. MEGA
16、CLI=/opt/MegaRAID/MegaCli/MegaCli64111. $MEGACLIgrepFirmwarestateawk-F:print$2,$1/tmp/fireware.log112. $MEGACLI-EMediaError|OtherError/tmp/disk.log113. foriincatbash.exedisk.sh131. #check132. MEGACLI=/G/raid_check/MegaCli.exe133. GREP=/G/raid_check/unixtools/grep.exe134. AWK=/G/raid_check/unixtools/
17、awk.exe135. CAT=/G/raid_check/unixtools/cat.exe136. CURL=/G/raid_check/unixtools/curl.exe137. $MEGACLI$GREP|$AWK-F:/c/fireware.log138. $MEGACLI$AWK/c/disk.log139. for$CATc:/disk.log140. do141. if142. 143. $CURL/xxxxxx&144. fi145. done146. for/fireware.log147. do148. if149. 150. $CURL/xxxxx&151. fi (注:文档可能无法思考全面,请浏览后下载,供参考。可复制、编制,期待你的好评与关注)
copyright@ 2008-2022 冰豆网网站版权所有