1、25.05.08,Seite 1,Setup DIG000/OP1000,Dez 2008BUA,25.05.08,Seite 2,OL81/DIG000/DM4000,Training overview:,Interface structureHow to Start-up the new components 1.OP1000(applicationsoftware)2.DIG000(applicationsoftware),25.05.08,Seite 3,DIG000 with MasterLogic and OP1000 Network,Ethernet,Can Group 07wi
2、th other sensorsOL80FR.Fx.FE.,Network 1,DIG000 Software:Pc0016-8003M+Application software xxx.xxxPossible communicationsMitshubishiSiemensBeckhoff.Standard Ethernet:Software Pc0016-8002M Ethernet Ip Software Pc0016-8010M EGD,OP 1000,PLC,Ethernet SwitchX8;24V DC(z.B.326491),Can Group 07with other sen
3、sorsOL80FR.Fx.FE.,Network 2,DIG000,DIG000,25.05.08,Seite 4,How to Start-up the new components,Change the PC-Ethernet settingsDownload Software to the DIG000Set the ip-address of the OP1000 PanelDownload software to the OP1000 PanelDownload PLC-software in DIG000Check the Dongle Value EK 5101,25.05.0
4、8,Seite 5,How to Start-up the new components,1.Change the PC-Ethernet settings,To get a ethernet connection between two devices you need a few conditionsA ethernet connection exists of following parts.,ip-address010.006.002.003Netmask255.255.000.000Gateway000.000.000.000,Device 1,ip-address010.006.0
5、02.124Netmask255.255.000.000Gateway000.000.000.000,Device 2,A connection is only possible if the blue numbers are the same,25.05.08,Seite 6,How to Start-up the new components,1.Change the Pc-Ethernet settings,Open the networksetting in your PC,10.6.2.4,To get a connection to the devicesSet the ip-ad
6、dress of the pc-ethernet cardTo a address like 10.6.x.x,Attention:If you connect a Pc direkt to a device you Need a cross-cabel.If the Pc and the devices are connected Over a ethernet switch you need a patch cabel.,25.05.08,Seite 7,How to Start-up the new components,1.Change the Pc-Ethernet settings
7、,Put in the ip-addressOf the DiG000,Open javacanmon,press the Add button,25.05.08,Seite 8,How to Start-up the new components,1.Change the Pc-Ethernet settings,If you dont know the ethernet address you have to set or read the ip-address1.With a seriell connection2.with Javacanmon Can-Dongle.recommend
8、ed,25.05.08,Seite 9,How to Start-up the new components,1.Change the Pc-Ethernet settings,Change to service,Select the Service functionSet TcpIp Addr andPress the buttonSet,25.05.08,Seite 10,How to Start-up the new components,1.Change the Pc-Ethernet settings,Connect the hardware to the PC.,Ethernet(
9、Cross cabel)z.B.328927(10m),25.05.08,Seite 11,How to Start-up the new components,1.Change the Pc-Ethernet settings,Here you see theActive connectionTo the hardware,25.05.08,Seite 12,How to Start-up the new components,2.Download software to the DIG000 or DM4000,Basicsoftware:PC0016-8008M_ZB,Basis Mas
10、terLogic:PC0016-8003M_ZD,Ehternet/IP:PC0016-8002M_ZC,Press the Download button,Change to Software,25.05.08,Seite 13,How to Start-up the new components,2.Download software to the DIG000 or DM4000,Select the software and press open,Download is onlyPossible over Ethernet,25.05.08,Seite 14,How to Start-
11、up the new components,3.Set the Ip-address of the OP1000 Panel,If you press with your fingers at the same time these points for At least 2s.The panel switch to the setup mode,25.05.08,Seite 15,How to Start-up the new components,Change with the keyboard to the function CONFIG and press ENTER,The pane
12、l switch to the configuration mode,3.Set the ip-address of the Panel,ENTER,25.05.08,Seite 16,How to Start-up the new components,3.Set the ip-address of the Panel,In the configuration mode You can see some informations.,Firmware,Networksettings,Timesettings,keyboard,25.05.08,Seite 17,How to Start-up
13、the new components,3.Set the ip-address of the Panel,In the configuration mode You can see some informations.,To change the Networksettings Touch this area.,25.05.08,Seite 18,How to Start-up the new components,3.Set the ip-address of the Panel,Set the new ip-Address And press EnterSet the netmask an
14、d pressEnterSet the Gateway and pressEnterPress 2 time Enter and the New settings change.,25.05.08,Seite 19,How to Start-up the new components,3.Set the ip-address of the Panel,Connect the OP1000 to the PC.,Ethernet(Cross cabel)z.B.328927(10m),25.05.08,Seite 20,How to Start-up the new components,You
15、 need the software UniDataexchanger from exor.Each application need a special panelsoftware named Project.rom,Select Download Project,Select the Firmeware,4.Download software to the panel,25.05.08,Seite 21,How to Start-up the new components,4.Download software to the panel,Open the optionCommunicati
16、on To select the ip-addressOf the panel,25.05.08,Seite 22,How to Start-up the new components,Select the OP1000,Here you have to be set the ip-address of the Panel.The Panel must connected to the PC,You also can try the ButtonPick UniOP.All connected Panels are showed and you Can select the needed panel,If no panel is showed in the Pick UniOP you have no connection,4.Download software to the panel,25.05.08,Seite 23,How to Start-up the new components,Befor you can download a programm the panel hav