电脑技术员英文自我评价.docx
《电脑技术员英文自我评价.docx》由会员分享,可在线阅读,更多相关《电脑技术员英文自我评价.docx(5页珍藏版)》请在冰豆网上搜索。
电脑技术员英文自我评价
电脑技术员英文自我评价
电脑技术员英文自我评价篇一
SincethecompanyinAugust2018Iwasawardedthetitleofthetechniciantothepresent,hasbeenfouryearstime.Inthesefouryears,Ihavebeenintheoperationdepartment,byvirtueoftheirowneffortsandleadershiptohelp,fromamaindutyofficerpromotedtothedutychief,andwaspromotedtothepostofassistant.Duringthisperiod,Ihaveourfirststationofthesystemhaveabetterunderstandingandawarenessofsomeofthevarioustypesofaccidentshaveacertaindegreeofindependentanalysisandprocessingcapabilities,atechniciantodoagoodjobduties.
Mymajorintheschoolofthermalandautomationcontrolprofessional,butinthefirststationtorunourworkismostinneedofheat,electricalandotheraspectsofknowledge.Thisisformeanewchallenge,butalsotheneedforcontinuouslearningtoimprove,sothattheirprofessionalskillscanbefullydeveloped.So,Igotsomebooksabouttheseareas,targetedtooursystemoflearning,butalsoasksomeoftheoldmasterandprofessionals,askthemtoshowuppreaching.Throughtheirowneffortsandthehelpofcolleagues,finallyworkpaysoff,myprofessionalknowledgeandprofessionalskillshavebeengreatlyimproved.
ButIhavealotofknowledgeaboutthethermalaspectsofoursystemandareparticularlyinterestedinitandhaveathoroughunderstandingofit.Whileatthesametimelearnfromtheirown,butalsoassumeresponsibilityforpreachingtootheroperationalpersonnel.Ourcompany'shotwaternetworkprojectistheuseofcomputermonitoringsystemtoachievehotwaterproductionandoperationofthecomprehensivemonitoringofthedata.Itsmaincomponentsincludethecontroller,inputandoutputmodulesandmonitoringstations.Ourcompanyhas18setsofSCAN3000/S9000distributedcontrolsystem(DCS),whichhasthefunctionsofhotwaternetworkoperationloopcontrol,dataacquisition,datacommunication,centralizedinformationmanagementAndoperationdisplayfunctions.ItisequippedwithtwoS9000controllers,andanother12single-loopcontroller(HonewellUDC3300),asthecontrolloopredundancycontrollerandemergencyhandterminal.UDCasabackuphand-helddevicecanDCSintheeventoffailure,thecontrollooptocontrol.Witheasytooperate,programmable,highstabilitycharacteristics.
DCSsystemandUDCcanachievebetweenthenon-disturbanceswitch,toensurethestabilityofthesystemoperation.S9000controllerthroughtheDVCcommunicationportoftheDMCcommunicationcircuitandsingle-loopcontrollertoachievecommunication;throughtheMGTSTAcommunicationportandthesystemmonitoringstationcommunicationcardconnected.Withthesecontrolsystems,usuallyavarietyofparametersoftheregulationandpersonnellaborwillhaveamultipliereffect.Thesecontrolsystemsaremadeupofmeasuringelements(temperaturetransmitters,pressuretransmitters,differentialpressuretransmitters),controlelements(S9000,UDC),actuators(regulators,etc.).Controlflowissuchthatthescenecollectsdatafromameter,thetransmittersends4-20mAsignaltotheS9000(thatisoftensaidDCS),1-5VsignaltotheUDC.AndthenissuedbytheS9000orUDC4-20mAsignal(UDCserieswith250Ωresistor,1-5Vsignalto4-20mAsignal)toadjusttheactuator.Inthisprocess,theinstrument'spowersupplyfromthetwoSiemens24VDCpowersupply(thetwopowersupplyeachotherspare),thepowertothedistributor,andthenbytheelectricaldistributiontoaprimarymeterpowersupply(themiddleofelectricaldistributioninordertometerrepair,Willnothaveashortcircuit,anddamagetheDCpowersupply).DCSorUDCreceivesthesignalthatisdisplayedontheCRTorUDCownscreen.DCSorUDCcontrolsignaltotheimpedanceconverter,distributor,theisolationmoduleorisolatedrelayrelaytotheexecutivecontrol.
Isolationmoduleisthroughtheanalogsignal,thatis,continuouscontrolsignal4-20mA,suchasthevalveopening,levelcontrol;andisolationrelayistheswitchsignaltotheDCS,suchastemperatureswitches,pressureswitchesandpumpsStart,stopstate,etc.(plusisolationmodule,isolationrelayistoisolatestrongsignals,soasnottoS9000intheloopcontrolcardburned).
Duringtheshift,asamonitor,Iassumetheresponsibilityoftheentirehotwaternetworksecurityandeconomicoperation,thespiritofahighdegreeofconcentrationduringwork,leadingtheteammemberscarefullyadjusttheparameters,carefulanalysisofthedata,sumupthelaw,Foundthatequipmentdefectsandrisks,topreventtheexpansionoftheaccident.Notonlytoensurethesafeoperationofthehotwaternetwork,butalsototheeconomicoperation.Insomeparametersandequipmentanomalies,candoatimelyanalysis,findoutthereasonsandreport,withacertaindegreeofind