List of docs on EMCFunctional Safety 28 Nov 06.docx
《List of docs on EMCFunctional Safety 28 Nov 06.docx》由会员分享,可在线阅读,更多相关《List of docs on EMCFunctional Safety 28 Nov 06.docx(18页珍藏版)》请在冰豆网上搜索。
ListofdocsonEMCFunctionalSafety28Nov06
CherryCloughHouse
9BrackenView,Brocton
Stafford,ST170TF,UK
tel:
+44(0)1785660247
fax+44(0)1785660247
email:
keith.armstrong@
web:
ListofresourcesonEMC-relatedFunctionalSafety
Thesemaybereferredtoinpapersandarticles,and/ormayserveasusefulsources
ThiseditionofthislistwascreatedbyKeithArmstrongon28thNovember2006
–newmaterialsinceJanuary2005isshownwithayellowhighlight
Ifyouknowofanyotherrelevantdocuments,presentations,standardsorreferences,pleaseletmeknow.
Thislistisavailableon-lineat:
http:
//www.iee.org/OnComms/PN/emc/EMCandFunctionalSafety.cfm
whichincludeslinkstomanyofthedocumentslisted
Contents
1RelevantStandardsandGuides1
2‘EMC-RelatedFunctionalSafety’seminar,London,22ndMarch20012
3WorkshoponFunctionalSafetyandEMC,EMCEurope2000,Bruges,Sept11-1520003
4Otherarticles,papers,publicationsetc.whichincludeEMC-relatedfunctionalsafetyissues3
1RelevantStandardsandGuides
1.1EMCforMachinerySafetyandCompliancewiththeMachinerySafetyDirective
EMCTestLabsAssociation(EMCTLA)TechnicalGuidanceNotenumber45(TGN45)availablefromwww.emctla.co.uk
1.2EMCD/LVDguidancedocument(EMCforCompliancewiththeLowVoltageDirective)
EMCTestLabsAssociation(EMCTLA)TechnicalGuidanceNotenumber46(TGN46)availablefromwww.emctla.co.uk
1.3PDR0BT-004:
2002ECDirectives,functionalsafetyandtheroleofCENELECstandardization
1.4IEC/TS61000-1-2:
2001ElectromagneticCompatibility(EMC)–Part1-2:
General–Methodologyfortheachievementofthefunctionalsafetyofelectricalandelectronicequipmentwithregardtoelectromagneticphenomena
1.5IEEGuidancedocumentonEMCandFunctionalSafety
InstitutionofElectricalEngineers,London,2000.
Homepage:
http:
//www.iee.org/Policy/Areas/Emc/index.cfmandfreelydownloadableasa‘Core’documentandnine‘IndustryAnnexes’inWordandPDFformatsfrom:
www.iee.org.uk/Policy/Areas/Electro/.
(Note:
bothoftheseURLsarecasesensitive,sotypethemexactlyasshownabove).
ItisOKto‘cutandpaste’partsofthisguideaslongastheirIEEsourcedocumentisacknowledged.
ButalthoughtheguideisfreelyavailablefromtheIEE,itisapparentlynotacceptabletotheIEEtocopyitandmakeitfreelyavailableyourselfevenwithfullacknowledgement.
1.6IEC61508(sevenparts)Functionalsafetyofelectrical/electronic/programmableelectronicsafety-relatedsystems
IhaveadetailedlistofallthereferencestoEMC-relatedissuesinIEC61508’ssevenparts,whichIwillemailifrequiredinWordformat.
1.7Safecheck:
apracticalguidetousingIEC61508
ThisisagraphicalguidethatsteersyouthroughIEC61508andpromptsyoutodothenecessarydocumentation.IthasbeendevelopedbyProfessorJohanCatrysseatKHBOUniversity,Belgium,forusebycompanieswhocannotaffordtoemployafull-timesafetyspecialist.Theapplicationanditsguidesarefreelydownloadablefromaddressesprovidedbytheinstallationguideat:
http:
//khbo.be/emc/PrUtS16s29a4f9e/Hobusafe.zip.
BesuretofollowtheinstructionsintheInstallationGuide.IfyouhaveproblemsindownloadingorwouldpreferitonaCD-ROMinstead,contactProf.Catrysseatjohan.catrysse@kh.khbo.be.
1.8IEC61511Functionalsafetyinstrumentedsystemsfortheprocessindustrysector
BasedonIEC61508.
1.9DraftIEC62061Functionalsafetyofelectrical/electronic/programmableelectroniccontrolsystemsformachinery
BasedonIEC61508.
1.10MIL-STD-464,18March1997DepartmentofDefenseInterfaceStandard–ElectromagneticEnvironmentaleffects–RequirementsforSystems
ContainsagreatdealofadvicebasedonexperiencewithEMC-relatedreliabilityandfunctionalsafetyissues(includingfuelandexplosives)intheUSA’smilitaryforces,includingsomeenvironmentswithveryhigh-levelelectromagneticthreats,suchascloseproximitytopowerfulradarsanddirectlightningstrikes.ItiseasiesttofindfreedownloadsitesforUSmilitarystandardsbytypingthenumberofthestandardrequiredintoGoogle().
2‘EMC-RelatedFunctionalSafety’seminar,London,22ndMarch2001
ThisIEEseminarwaspartoftheEFT2001conference,heldattheExCelCenter,LondonUK,onthe22ndMarch2001.IhavenearlyallthepresentationsasPowerPointfiles.Eachofthesepresentationstakesabout20minutes.
2.1WhywenowneedtoconsiderEMCforfunctionalsafety
DrPeterKerry,RadiocommunicationsAgency,PresidentofCISPR
(PowerPoint:
2.84MB,11slides)
2.2FunctionalsafetyandIEC61508
RonBell,HeadofElectricalandControlSystemsUnit,HealthandSafetyExecutive
(PowerPoint:
357kB,37slides)
2.3ThedraftIEC61000-1-2:
"EMCandfunctionalsafety"
SimonBrown,PrincipalSpecialistInspector,HealthandSafetyExecutive
(PowerPoint:
113kB,11slides)
2.4AprocedureformanagingEMCtoachievefunctionalsafety
KeithArmstrong,Partner,CherryCloughConsultants(chairoftheIEEWorkingGroupthatproducedtheIEE’sGuideonEMCandFunctionalSafety)
(PowerPoint:
1.13MB,23slides)
2.5Buildingservicesandelectricitydistribution
DrOonaNanka-Bruce,ConsultantEngineer,ERATechnologyLtd
(PowerPoint:
notavailable)
2.6Healthcare
VicClements,RFITechnologyLtd
(PowerPoint:
77kB,14slides)
2.7Offshoreoilandgas
RogerEmberson,HeadofTelecommunications,KvaernerOilandGas
(PowerPoint:
804kB,14slides)
2.8Railtransport
DrBobHolmes,GreenLeaderLtd
(PowerPoint:
1.07MB,10slides)
2.9Roadtransport
ChrisMarshman,Director,YorkEMC
(PowerPoint:
177kB,17slides)
2.10Softwareissues
DrDavidWard,ManagerAdvancedEngineering,ElectricalGroup,MotorIndustryResearchAssociation(MIRA)
(PowerPoint:
800kB,19slides)
2.11ControllingEMCinheavyengineeringprojects
JohnWhaley,Director,WorldWideInternationalElectricalApprovals
(PowerPoint:
227B,12slides)
3WorkshoponFunctionalSafetyandEMC,EMCEurope2000,Bruges,Sept11-152000
Allofthesearepublishedintheconferenceproceedings:
ISBN90-76019-14-2D2000/0277/4TechnologischInstituutvzw,Volume2,pp361-383,whichIhaveinhardcopyformatonly.
3.1IntroducingtheIEE’sdraftGuidancedocumentonEMCandFunctionalSafety
KeithArmstrong,chairoftheIEEWorkingGroupthatcreatedthisguide
3.2IntroductionoftheIECandCENELECworkonFunctionalSafety
GeorgesGoldberg,ConvenorIECTC77,WG14
3.3ExampleoftheapplicationofIEC61000-1-2
(FaultTreeanalysisofanelectronicgasburnercontrollerwithrespecttoelectromagneticphenomena)
DickGrootBoerle,ThomsonCSF–Signaal,NL,memberWG14
3.4ExampleoftheapplicationofIEC61000-1-2
(FaulttreeanalysisofanHVsubstation)
GeorgesGoldberg,ConvenorIECTC77,WG14
3.5IntroductiontoIEC61508inthecontextofEMC
SimonJBrownandNeilAGove,HealthandSafetyExecutive,UK
4Otherarticles,papers,publicationsetc.whichincludeEMC-relatedfunctionalsafetyissues
Theseareinadditiontothoselistedinsections1-4aboveandIhavemostofthemonlyaspapercopies,notinelectronicformat.Icouldfaxthepapercopiestoafewpeopleiftheywerereallyinterestedinthemandcouldn’tgetthemanyotherway.
4.1BananaSkins
AregularcolumnintheEMCComplianceJournalforoverfouryears,brieflydescribinginstanceswhereEMCproblemshavebeenexperienced.SomeoftheitemsinthisseriesconcernEMC-related-safetyissues.(AllEMCJournalandEMCComplianceJournalarticlesareavailableon-linefromthearchiveatpliance-.)
Thereisalsoa‘BananaSkinsCompendium’documentthatincludesthemall,whichcanbedownloadedfromthe‘Publications&Downloads’pageat.
4.2TheEffectonCableThreatsofManyDifferentLightningAttachmentScenarios
DrChristopherCRJones,EMC-UK2006Conference,NewburyUK,October17-182006,pp75-78,ProceedingsavailablefromNutwoodUK,sales@
4.3Risk-BasedCompatibility–OutlineConcepts
TimHaynes,EMC-UK2006Conference,NewburyUK,October17-182006,pp79-89,
ProceedingsavailablefromNutwoodUK,sales@
4.4ARisk-BasedApproachtoEMConRailProjects
DarrenHayes,EMC-UK2006Conference,NewburyUK,October17-182006,pp90-98,
ProceedingsavailablefromNutwoodUK,sales@
4.5MeetingCommercialEMCRequirementsinSafetyCriticalEquipment
TonyMaddocks,EMC-UK2006Conference,NewburyUK,October17-182006,pp99-102,ProceedingsavailablefromNutwoodUK,sales@
4.6DesignandMitigationTechniquesforEMCforFunctionalSafetyandHighReliability
KeithArmstrong,EMC-UK2006Conference,NewburyUK,October17-182006,pp103-109,ProceedingsavailablefromNutwoodUK,sales@
4.7WholeAircraftHIRFTestExperiences:
APracticalViewpoint
RogerMarson,EMC-UK2006Conference,NewburyUK,October17-182006,pp113-116,ProceedingsavailablefromNutwoodUK,sales@(especiallypage114)
4.8DO160/ED14“F”Revision
TimNoadandDrNigelCarter,EMC-UK2006Conference,NewburyUK,October17-182006,pp117-119,ProceedingsavailablefromNutwoodUK,sales@(especiallypage118)
4.9DirectCurrentInjection–AnAlternativetoHighIntensityRadiatedFieldTestforEMCClearanceofMobilePlatforms
AGLlewellynandAMWellington,EMC-UK2006Conference,NewburyUK,October17-182006,pp120-122,ProceedingsavailablefromNutwoodUK,sales@(especiallytheIntroduction)
4.10DesignandMitigationTechniquesforEMCforFunctionalSafety
KeithArmstrong,IEEE2006InternationalEMCSymposium,Portland,OR,USA,
A