机房搬迁项目建议书.docx
《机房搬迁项目建议书.docx》由会员分享,可在线阅读,更多相关《机房搬迁项目建议书.docx(15页珍藏版)》请在冰豆网上搜索。
机房搬迁项目建议书
机房搬迁项目建议书
篇一:
移动公司上街网管机房设备改造暨搬迁工程项目建议书
移动公司上街网管机房设备改造暨搬迁工程
项目建议书
目录
一、工程概述···········································································1
...................................................................................................................1
...............................................................................................................................1
.......................................................................................................................1
二、机房计划及配套··································································1
1整体原那么...............................................................................................................................1
...............................................................................................................................2
........................................................................................................................2
................................................................................................3
...............................................................................................................................4
三、网络建设方案····································································5
...................................................................................................................5
........................................................................................................................5
........................................................................................................................5
................................................................................................................6
2治理网络建设方案...............................................................................................................7
........................................................................................................7
................................................................................................................8
...............................................................................................9
...................................................................................................9......................................................................................................................9
..............................................................................................................1010
四、硬件基础架构建设方案·······················································11
.............................................................................................................11
.............................................................................................................................11
.................................................................................................12
4系统部署方案.....................................................................................................................14
.................................................................................................................15
五、搬迁方案·········································································15
.............................................................................................................................15
.....................................................................................................................16
3项目实施内容.....................................................................................................................16
.............................................................................................................16
.................................................................................................17
..............................................................................................................1717
..............................................................................................................17
......................................................................................................18
..............................................................................................................1919
......................................................................................................19
..........................................................................................19
六、远期目标·········································································20...................................................................................................................20...................................................................................................................20...................................................................................................21
七、投资估算·········································································22
八、工程进度安排···································································24
九、附件···············································································24
1工程背景及现状
网管支撑机房位于电信器材一厂枢纽楼4、5层,目前一厂枢纽大楼电源系统较为紧张,同时网管机房已经不能知足业务快速进展带来的空间需求。
空间不足:
目前一厂四五楼网管机房,安装有157机架,300余台设备,机房利用空间达95%,剩余空间不足以知足后续网络的进展需求。
配套电源不足:
目前负荷采样数据是1600A,电池充电电流660A。
考虑到夏日的空调负荷将比冬季增加20%,夏日总负荷将达2420A,变压器负荷达到83.8%以上,油机负荷达到87.7%以上。
由于以上缘故,致使08,09年部份项目硬件设备无法上电,网管系统硬件处于超负荷状态;依照公司整体计划上街局楼5层将做为省网管支撑系统机房,在此背景下,XX公司结合网管支撑系统实际情形,提出了中国移动XX公司网管机房搬迁工程的建设项目,解决当前设备上电上架问题,同时减缓一厂枢纽楼供电紧张的局面。
2建设内容
依照整体计划,上街五楼机房将作为网管支撑系统设备机房。
考虑到近期网管工程需要,本期先启用上街五层南面机房,机房面积约509.8平方米,要紧放置省级网管设备和其他系统的扩容设备。
本期工程将涉及到以下几个方面:
(1)机房计划及配套设备建设:
功能区划分、配套电源等设备建设;
(2)网络建设:
进行上街节点网管网络搭建,保障网管系统稳固运行,支撑网管设备远程集中保护治理;
(3)硬件基础架构建设,基于报废替换设备,引入云计算技术进行网管系统硬件资源池的搭建,为后续整体硬件平台向云环境演进奠定坚实基础;
(4)主设备搬迁,涉及电子运维、话务网管、综合监控、客服支持、数据集市、网优平台等28套系统。
3工程建设规模
中国移动XX公司上街网管机房设备改造暨搬迁工程项目总投资约为1641万元人民币。
二、机房计划及配套
1整体原那么
(1)前瞻性及灵活性
本机房的计划及配套电源设计应立足于业务系统久远的进展需求,统一规
篇二:
广电机房搬迁方案建议书
广电机房设备搬迁实施方案
建
议
书
中天科技股分
第1章
设备迁移方案
1.1迁移流程及顺序说明
以上为系统迁移的流程图,各单位数据中心分系统均按该流程进行,做到系
统迁移的有序进行。
1.2迁移实施前期预备
迁移的预备工作是整个迁移工作的极为重要的部份,充分的做好本次迁移的预备工作,是保证迁移工作顺利进行的首要条件,并可有效的减少迁移进程中的事故隐患,以下将对迁移前的预备工作做详细描述。
2.1迁移设备确认
在此进程中需和用户方确认迁移的网络设备、效劳器、存储等硬件设备及其辅助设备和材料,并对需迁移的设备进行分类统计,形成文档,由用户方确认。
2.1设备检测
(一)硬件设备的检测
在迁移以前,用户方应付现有的设备进行一次全面的检测工作,包括系统状态、组件和系统配臵的检测,确认系统迁移恢复后应具有的功能和性能。
(二)效劳器软件应用系统的检测
配合业务系统的开发保护单位,对系统的集成接口、设备连接进行检测,确认系统迁移恢复后应具有的功能和集成方式。
2.1数据备份
做好数据备份工作是本次搬迁工作顺利完成的有效保障之一,对各系统配臵参数和配臵文件做有效的记录和保留,形成文档,为系统再运行、集成提供充分的依据。
2.1设备及接口标识
迁移工作比较繁琐,尤其值得注意的是,在系统的再集成进程中,设备物理连接的恢复将是系统再集成的首要保证,众多单位的业务系统与及数量繁多的设备容易引发觉场的混乱,模糊不清或意义不明确的设备标识、标识的丢失等因素将阻碍系统恢复运行的时刻。
因此在迁移以前对所有的硬件设备做好编号和功能标示,对物理连接的接口和线缆做好标识,对设备、接口、线缆做到一一对应,并将以上标识内容形成文档,为系统快速恢复提供靠得住的基础。
标识要紧内容为:
?
效劳器设备标识:
在设备做好标示,注明设备的型号、配臵、功用、接
口信息等信息;
?
网络设备标知:
注明设备型号、配臵、功用、接口信息等信息;?
线缆标识:
接口类型、连接设备等信息。
设备的标识工作已经按现有机房设备摆放位臵的格局做好的标识区分。
在设备迁移到指定位臵后再次做好标识,并整理成册为以后治理做好基础的依据。
1.3设备迁移步骤及注意事项
设备迁移是指从硬件设备及业务系统停运、拆卸下架、改换机柜、内外网分区域部署、从头上架、系统开机运行的进程,此进程是迁移工作的重点之一,需做好详细的计划,保证迁移工作的顺利进行。
2.1系统停机步骤及注意事项
迁移前应关闭网络设备及效劳器系统,具体步骤及内容如下:
(一)停运步骤
1.系统停运时刻应和用户方协商决定暂建议元月15日进行设备第一次迁移;
2.对小型机、效劳器系统及存储蓄份系统停运前应事前由用户、应用系统保护
单位沟通进行数据备份和停机;
3.确认设备配臵及系统配臵文件已做好记录和备份;
4.PC效劳器停机:
PC效劳器关闭应用软件系统,关闭系统,切断电源;
5.小型机停机:
小型机停数数据库,关闭系统,切断电源
6.
存储系统停机:
磁盘阵列关机,切断电源;光互换机关机,切断电源;
7.备份系统停机:
备份效劳器和磁带库关闭系统,切断电源;
8.网络及平安设备停机和拆离,在网络机架上依照互换机、核心互换机、路由
器、入侵检测、防火墙的顺序将设备依次关闭,待系统完全停止后切断电源;
(二)注意事项
1.设备停机时应按各设备利用单位,按不同业务系统进行有序停机;
2.设备切断电源前,应确认设备已经完全关闭,部份设备关机时刻较长,应等
其风扇完全停转后切断电源;
3.确认业务系统软件停运注意事项,严格依照系统软件停运步骤进行操作;
4.停机顺序依照先停运业务系统,再停运数据库、存储系统、备份系统、网络
系统的原那么进行;
5.系统停机时如发生软件或系统故障,应先排除再进行停机操作,不得野蛮停
机,确保操作系统和业务软件系统停运时无端障;
6.切断电源时应先关闭电源插座,再拔设备电源;
2.1设备拆卸步骤及注意事项
待机房设备全数停运并切断电源后,方可对设备进行拆卸,设备拆卸步骤和注意事项如下:
(一)拆卸步骤
1.拆卸应本着“先外后内,先周边再主体”的原那么;先拆卸设备周边连接附件
及线缆,再拆卸主机;
2.设备下架时应由上自下,对机柜内设备进行一一拆除,并依照业务系统进行
分类,待新机柜安装好后设备再安装于指定地址。
(二)注意事项
1.拆除设备时确认周边设备已经全数断开连接,避免线缆下架时拖连;
2.拆卸设备时应注意对设备爱惜,对体积和重量较大的设备需提供托架;
3.设备拆卸时应依照要求佩带静电爱惜设备,如:
静电护腕等,确保拆卸时静
电可不能对设备造成损害;
4.设备码放时应严格遵守设备的放臵要求,杜绝将设备倒臵、倾斜等随意堆放;
5.小型机、存储、核心互换机等设备体积大、重量较重,拆卸时应注意人员及
设备的爱惜,确保设备和人员平安。
6.设备拆卸时,应严格依照设备安装和拆卸指南进行,不得野蛮拆卸。
1.4机柜、桥架安装与设备迁移和谐步骤
2.1机柜安装
新机柜进场替换原有机柜的安装步骤:
1.拆除原有机柜内的设备,并将老机柜搬移出机房,将新机柜安装在设计好的
位臵。
2.在新机柜中按编号,分层次,按计划的安装各单位效劳器。
效劳器计划是按
照专网和外网划分摆放区域,因考虑到同一单位效劳器设备集中摆放利于治理员治理,这次需要搬迁的是原先18-23号机柜专网效劳器搬到新计划的区域。
3.新机柜按计划好的位臵顺序替换老机柜,新机柜中设备摆放按同一网内同一
单位的设备在一路集中部署的原那么进行。
4.关于外网网络机柜改换的步骤是:
第一将外网的效劳器设备迁移到新机柜,
并继续利用原有老线路,待新的布线系统完成后将接入互换机安装在网络列头柜中,再改换互联网的网络机柜。
2.1上走线桥架安装
在机柜、效劳重视新部署就位后开始安装上走线桥架,当上走线桥架安装完毕,新布线系统敷设完成后,再利用新的线路替换原有线路。
保证各效劳器设备在改换机柜时能够在很短的时刻内恢复工作。
篇三:
机房搬迁项目实施方案之风险评估和项目治理
第一章风险评估和应急处置预案
1.1风险评估
设备搬迁中的损坏风险规避:
效劳商向客户确认设备保修状况,由效劳商对需要搬迁的设备投保货物运输险,效劳商依照客户的要求进行搬运;关于搬运后显现设备损坏问题,效劳商通过备机备件在最短时刻内解决)。
数据显现不可恢复的丢失或损坏等风险规避:
在搬迁前对关键数据进行备份。
在搬迁中显现数据丢失的情形,通过备份数据进行恢复。
从效劳商正式实施搬迁工作开始,即安排人员、工具及备用设备在新机房现场随时待命,一旦发觉问题,效劳商当即启动备机备件方案。
以保证设备正常上线并投入利用。
?
风险评估:
?
搬运进程有可能致使一些老设备的硬件松动;?
静电有极低的机率会对设备运行产阻碍;?
在搬运进程中偶然的设备损伤;
?
应急方法:
?
搬运进程中做到尽可能的警惕,轻拿、轻放;
?
做好防静电方法,尽可能的幸免静电对设备产生阻碍;?
和谐各效劳商部门,确保相关设备配件有存货;?
由现场工程师对处于异样状态的搬迁设备进行大体保护?
对那些进行大体保护还不能够正常运行的设备进行报修
(报修的设备需在爱惜效劳期内,关于过保设备效劳商不承担相关责任);
?
关于重要的业务系统应利用相应的备件或相应的后备方
案,以保证业务系统及时运行;
?
协助客户利用带机和备份介质对相关已知的丢失了数据
的设备进行数据恢复(效劳商仅提供相关技术支持,具体操作和数据的完整性由客户完成)。
1.2应急处置预案
针对搬迁现场发生的各类故障,起草以下应急处置方案。
效劳商将将尽力修复故障问题,以不阻碍客户业务运行为前提。
1.3备机备件
通过迁移前的资产统计,能够更细致了解一些重要设备的型号、配置。
在迁移进程中,为了更好的避免突发事件的显现,效劳商还会为效劳器提供一些备机备件,确保在突发事件显现时能够及时地恢复效劳器的正常运行。
依照每批次搬迁100台设备计算,咱们会预备搬迁数量的3%,也确实是2台PC效劳器和1台小机做备机,而且还会预备一些硬盘和内存的备件。
第二章项目治理
1.1项目治理
优秀的项目治理是项目成功的一个基础保证。