HCP100A英文操作维护手册B.docx
《HCP100A英文操作维护手册B.docx》由会员分享,可在线阅读,更多相关《HCP100A英文操作维护手册B.docx(41页珍藏版)》请在冰豆网上搜索。
HCP100A英文操作维护手册B
PALLCORPORATION
INSTALLATION,OPERATIONAND
MAINTENANCEMANUAL
HCP100ASERIES
Turbineoil
ConditioningPurifier
PallFilter(Beijing)Co.,Ltd.
No.12,HongdaNanlu,BeijingEconomic&TechnologicalDevelopmentArea
PostCode:
100176
Tel:
(010)67802266Fax:
(010)67802319
Foreword
Thismanualisprovidedtoserveastheinstallation,operationandmaintenance
guidefortheequipmentsuppliedinaccordancewiththedetailsgiveninthe
customer'spurchaseorder.Thecontentsshouldbereadbeforeattemptingany
phaseofinstallation,operationandmaintenance.
Theequipmentandanyoptionalitemsarepackedindividuallyforassemblyby
thecustomer.Unpackcarefullyandcheckallitemsreceivedagainsttheinvoice.
ThisequipmenthasbeentestedandqualitycontrolledinaccordancewithPall
standardproceduresandalsoinaccordancewiththetestsspecifiedinthecontract
whenrequired(i.e.forspeciallydesignedequipment).However,theequipmentas
shippedmayhavebeenopenedordisassembledfordraining,cleaning,etc.,after
testing.Thecustomershouldsatisfyhimselfthatnonuts,bolts,flanges,pipes,
closuresoranyothercomponenthaveworkedlooseduringshipment;theseshouldbetightenedwherevernecessary.
Anameplatehasbeenpermanentlyattachedtotheequipment.Whenrequestinginformation,serviceorspareparts,pleaserefertotheinformationgivenonthisplate.
Itistheuser'sresponsibilitytocheckactualoperatingconditionstoensurethatthefilterelements,vesselandsealingmaterialsarecompatiblewiththeapplicationandarewithinlocalsafetycodes.
MANUALPARTNUMBER
ISSUE
DATE
MANHCP100A
B
JULY2006
Contents
Abstract
3
PartNumber
4
DesignData
5
AlarmConditions
7
Storageandinstallation
11
Storage
11
Pre-installationinspection
11
ConnectionofHCPtoFluidSupply
12
ConnectionofElectricalPowerSupply
15
Operatorinterface
17
Introductionstointerface
17
Mainmenu
18
GettingStarted
22
Waterremovalcirculation
Filtrationcirculation
22
23
Systemdrain
24
Maintenance
25
Routinemaintenanceschedule
25
Routinemaintenanceactivities
25
Faultfinding
27
Appendix
29
Listofspareparts
29
PalldrawingsHCP100AINST:
2sheetsintotal
PalldrawingsH0473.E-A:
5sheetsintotal
Abstract
ThisunitdesignedbyPall,isdedicatedforfiltrationandwaterremovalofturbineoil.Itincorporatestogetherthefunctionsoffinefiltrationandhighefficiencywaterremovalofoil.Itcaneffectivelyremovesomesolidparticlesandemulsion,freewaterinoil.Afterthat,theoilcleanlinesslevelisuptoNASLevel6,andthecontentoffreewatermaybelowerthan100PPM.
Functionsofthisunit:
1.Filtrationcirculation:
couldbeusedassolidparticlefiltrationequipmentindependently.
2.Waterremovalcirculation:
couldremovetheemulsionandfreewaterinturbineoil.
Featuresofthisunit:
1.No-watchrunning:
Itcanrunsmoothlyduringnormaloperationafterdebugging,whilerequiringnobodytowatchit.
2.Automaticemergencyalarm:
Itcanautomaticallyalarmandpromptoperationmethodswhenabnormalconditionoccursandmaintenanceisneeded.
3.Automaticemergencystop:
Itcanautomaticallyshutdownthesystemwhenaseriousemergencyoccurs.
4.Systemstatusdisplay:
Thehuman-computerinterfacecandisplaycurrentandpreviousoperationdata.
5.Telemetryunitstatusdisplay:
Realtimedisplayofunitstatus.
Theoryofthisunit:
1.Filtrationtheory:
HighperformancePallUltiporIIIfiltersincorporatestate-of-the-artdesigntechnology,includingauniquepatented“helicalwrap”pleatsupportsystemandcompositeelementstructureforunsurpassedstrength,performanceandservicelife.Theresultisacost-effectivesolutionclearlysuperiortotraditionalfilterdesigns.
2.Waterremovaltheory:
Whenoilentersthecoalescer,firstlyitenterscoalescerelement.Freewaterandemulsifiedwaterbecomelargerdropsofwaterafterpassingfilterelementduetothepeculiarpolaritymoleculesincoalescerelementmaterials.
BeforeOilentersseparatorelementabove,relativelylargewaterdropsinoilhave
fallentothewaterbagbelowduetogravity.Therearestillsomerelativelysmall
waterdropsgouptoseparatorelementwithoilduetoinertia.Separatorelement
ismadeupofspecialhydrophobematerials.Whenoilpassesseparatorelement,
waterdropsarekeptoutside.Thenoilentersseparatorelementandgooutfrom
theoutlet.Waterdropsgatherandbecomelargerandatlastfallintothewaterbag
duetogravity.
PARTNUMBER
HCP100AturbineoilpurifierpartNumber:
HCP100AR3AC
ABCD
A:
“K”meansvoltage200V,3Ph.,230Vac/24Vdccontrolcircuit;
“M”meansvoltage220V,3Ph.,230Vac/24Vdccontrolcircuit;
“N”meansvoltage230V,3Ph.,230Vac/24Vdccontrolcircuit;
“R”meansvoltage380V,3Ph.,230Vac/24Vdccontrolcircuit;
“S”meansvoltage400V,3Ph.,230Vac/24Vdccontrolcircuit;
“T”meansvoltage415V,3Ph.,230Vac/24Vdccontrolcircuit;
“U”meansvoltage440V,3Ph.,230Vac/24Vdccontrolcircuit;
“V”meansvoltage460V,3Ph.,230Vac/24Vdccontrolcircuit;
“W”meansvoltage480V,3Ph.,230Vac/24Vdccontrolcircuit;
B:
“3”meansfrequency50HZ;
“4”meansfrequency60HZ;
C:
“A”meansstandardelementconfiguration,seetablebelow;
“K”meanshighefficiencyelementconfiguration,seetablebelow;
D:
“C”meansmobile;
“S”meansstable。
TableofpartNumberandelementconfiguration:
Model
Coalescer
Separator
Protection
Circulation
CN
QTY.
CN
QTY.
CN
QTY.
CN
QTY.
HCP100A
1202845
(standard)
5
1201652
1
1200339
(standard)
1
1200337
1
1202846
(highefficiency)
1200335
(highefficiency)
DesignData
1.Identification
Nameofequipment:
Pallturbineoilpurifier
Modeltype:
HCP100A
2.DesignOperatingConditions
Fluid:
Turbineoil
Fluidtemperaturerange:
+40℃~+70℃(104℉~158℉)
Maximumfluidviscosity:
<=46cst
Ambienttemperature:
-10℃~+60℃(14℉~140℉)
3.FluidSystem
InletPressure:
>=-0.045MPa
InletpumpP01flowrate:
100L/min
PumpreliefvalveRV01setting:
0.8MPa
InletstrainerFL01rating:
250μm
ProtectionfilterFL02rating:
β5(c)=1000(highefficiency)
β12(c)=1000(standard)
CirculationfilterFL03rating:
β7(c)=1000
OutletstrainerFL04rating:
250μm
Coalescerelementrating:
10μm(standard)
1μm(highefficiency)
VacuumswitchSP01setting:
-0.08Mpa
PressureswitchSP02setting:
0.7Mpa
DifferentialpressureindicatorSDP01setting:
0.24Mpa
DifferentialpressureindicatorSDP02setting:
0.30Mpa
DifferentialpressureindicatorSDP03setting:
0.24Mpa
4.MaterialsofConstruction
Baseframe:
Corrosionprotectedcarbonsteel
Vessel:
304stainlesssteel
Threadedfittingsandfastener:
Corrosionprotectedcarbonsteel
Controlpanelbox:
Corrosionprotectedcarbonsteel
5.SealingmaterialNitrile
6.Interfaces
Fluidinletport:
M64×2maleport
(forφ60×4weldingconnector)
Fluidoutletport:
M52×2maleport
(forφ50×4weldingconnector)
7.ElectricalSystem
Powersupply:
Seeunitnameplate
Totalmotorpower:
3kW(50Hz)
Connectedload:
Seenameplateforfullcurrentdetails
Powersupplyprotectionrating:
Tosuitfullloadcurrentshownon
unitnameplate.Maximum32A
8.INSTRUMENTATION
PLCdisplaywithkeypad(locatedoncontrolpanel)
Startpushbutton(locatedoncontrolpanel)
Stoppushbutton(locatedoncontrolpanel)
Emergencystoppushbutton(locatedoncontrolpanel)
Poweronlamp(locatedoncontrolpanel)
Dischargelamp(locatedoncontrolpanel)
Isolator(locatedoncontrolpanel)
Controlresetbutton(locatedoncontrolpanel)
Amberflashingbeacon(locatedontopofcontrolpanel)
InletvacuumgaugeVG01(righttocontrolpanel)
TemperaturegaugeTG01(righttocontrolpanel)
InletvacuumswitchSP01(locatedonpumpinletpipe)
OutletpressureswitchSP02(locatedonoutletpipe)
PressuregaugePG01,PG02,PG03(righttocontrolpanel)
DifferentialpressureindicatorSDP01(locatedonfilterFL02)
DifferentialpressureindicatorSDP02
(locatedondifferentialpressuremodule)
DifferentialpressureindicatorSDP03(locatedonfilterFL03)
DriptrayfloatswitchSL01(locatedinfluiddriptray)
WaterlevelsensorBLW01(locatedunderthewaterbag)
WaterlevelswitchSWL01(locatedondrainpipe)
AlarmConditions
AlarmandWarningMessages
Theoilpurifierisprovidedwithanumberofinterlocksandswitchestoensure
thatitoperatescorrectlyandsafely.Thetablebelowlistsallalarmconditions
fortheunit.
Theactivemodereferstotimesatwhichthealarmmaybeinvoked.The
actionshowstheresultofeachalarm.
CONDITION
INDICATION
ACTION
ACTIVEMODES
FUNCTION
SP01<-0.8BAR
HIGHINLETVACUUM
Themaximuminletvacuumis–0.8bar.Attemptingtoruntheunitwithsuchahighinletvacuumwillresultindamagetotheinletpump!
PressRESETtoreturn.
Shutdown
Running
Preventionofcavitationoninletpump.
SP02>7BAR
HIGHOUTLETPRESSURE
PressureswitchSP02detectedanoutletpressuregreaterthenthemaximumspecifiedrunninglimitof7bar.
PressRESETtoreturn.
Shutdown
Running
Preventionofhighoutletpressures,whichcancauseotherfaults.
SDP01>2.4BAR
(SDP01=PG02-PG01)
FILTERFL02BLOCKED!
Unlessthisisacoldstartcondition,thefilterFL02elementmustbechangedbeforedifferentialpressurereaches2.4bar;otherwise,unitwillshutdownafter120minutes.
Remainingtimeforshut-down:
XXXminutes
Afterreplacingtheelement,PressRESETtoreturn.
Warning
Running
Eliminationofunnecessaryshutdowns.
CONDITION
INDICATION
ACTION