1.輸入特性(InputCharacterization)
Page
Result
1-1效率及功率因素(Efficiency&PowerFactor)
1-2諧波電流(HarmonicCurrent)
1-3突入電流(InrushCurrent)
1-4輸入電壓瞬斷/保持時間(LineVoltageDropout/Hold-upTime)
1-5降低電壓/恢復(Brownout/Recovery)
1-6總諧波失真10%(TotalHarmonicCurrent10%)
1-7輸入電壓瞬昇(LineVoltageSurge)
1-8輸入電壓瞬降(LineVoltageSag)
1-9雷擊(PowerLineTransients)
2.輸出特性(OutputCharacterization)
2-1交越負載/輸入電壓變動率(LoadLineCrossRegulation)
2-2輸出漣波及雜訊(Ripple&Noise)
2-3動態負載變動率(DynamicLoadRegulation)
2-4電壓上昇及下降時間(RiseTime&FallTime)
2-5電壓過衝及過降(Overshoot&Undershoot)
2-6電源確認信號(PowerGoodSignal)
2-7遙控開/關機(Remoteon/off)
2-8電容負載(CapacitiveLoading)
3.保護(Protection)
3-1輸出短路保護(ShortCircuitProtection)
3-2輸出過電流保護(OverCurrentProtection)
3-3輸出過電壓保護(OverVoltageProtection)
3-4無載保護(NoLoadProtection)
3-5風扇控制/取代(FanControl/Override)
3-6輸出過溫度保護(OverTemperatureProtection)
4.可靠性(Reliability)
4-1開/關機循環(On/offCycling)
4-2電壓減額(VoltageDerating)
4-3溫升測試(TemperatureOperation)
4-4熱元件減額(ThermalDerating)
4-5零件應力(ComponentStress)
4-6故障發生前平均時間(MeanTimeBeforeFailure(MTBF))
4-7溫度係數(TemperatureCoefficient)
4-8穩定性(Stability)
4-9溫度循環(TemperatureCycling)
5環境要求(EnvironmentalRequirement)–委託外測
5-1振動試驗(VibrationTest)
5-1-1隨機振動測試(Operating)
5-1-2隨機振動測試(Survival)
5-1-3正弦波振動測試(Survival)
5-2衝擊試驗(ShockTest)
5-2-1Z軸上,下衝擊測試(EndUseHanding)
5-2-2運輸模擬測試
5-3電磁相容(ElectromagneticCompatibility-EMC)
5-3-1電磁干擾(ElectromagneticInterference-EMI)
5-3-1-1傳導干擾(ConductedPowerline)
5-3-1-2輻射干擾(RadiatedEmission)
5-3-2電磁耐受(ElectromagneticSusceptibility-EMS)
5-3-2-1靜電氣放電(ElectrostaticDischarge-ESD):
IEC802-2,IEC61000-4-2
5-3-2-2輻射耐受(RadiatedSusceptibility-RS):
IEC802-3,IEC61000-4-3
5-3-2-3電性快速脈衝(ElectricalFastTransient/Burst):
IEC802-4,IEC61000-4-4
6.安規(Safety)
6-1絕緣耐力(DielectricWithstanding(Hi-Pot))
6-2絕緣阻抗(IsolationImpedance)
6-3洩漏電流(LeakageCurrent)
6-4不正常測試(AbnomalTest)
1.輸入特性(InputCharacterization)
1-1效率及功率因數(Efficiency&PowerFactor)
目的:
量測電源供應器之輸出效率及功率因數
測試環境條件:
溫度25℃,相對濕度65%
測試電氣條件:
1.先開機10分鐘
2.輸入電壓以產品規格之全電壓頻率範圍
3.輸出負載以產品規格最大額定電流
結果判定:
以顧客所訂之規格判定;
效率百分比=輸出功率/輸入功率×100%
功率因素=輸出功率/輸入電源×輸入電流
測試設備:
1.AC電源供應器Chroma6560
2.電子負載機Chroma6310
3.功率瓦特表Prodigit4011
4.數位電表HP34401A
量測結果:
Input
(Vac)
Frequency
(Hz)
Iin
(Arms)
Pin
(W)
Pout
(W)
DissipatedPower(W)
Efficiency(%)
Power
Factor
95
47
115
60
132
63
190
47
230
50
264
63
1-2諧波電流(HarmonicCurrent)
目的:
量測電源供應器之諧波電流是否合乎IEC1000-3-2
測試環境條件:
溫度25℃,相對濕度65%
測試電氣條件:
1.先開機10分鐘
2.輸入電壓以100Vac/50Hzor230Vac/50Hz
3.輸出負載以產品規格最大額定電流
結果判定:
1.100Vac/50Hz以日規判定;or
2.230Vac/50Hz以歐規判定
測試設備:
1.AC電源供應器Chroma6560
2.諧波分析儀Chroma6630
3.電子負載機Chroma6310
量測結果:
日規ClassA
Pin(rms)
(W)
Harmonic
Order
Harmonic
Limits(A)
MeasuredHarmonicCurrent(A)
Results
Pass/Fail
Watts
3
5.29
Iin(rms)(A)
5
2.662
AMP.
7
1.771
9
0.92
11
0.759
13
0.483
15
0.345
17
0.304
19
0.272
21
0.246
23
0.225
25
0.207
27
0.192
29
0.178
31
0.167
33
0.157
35
0.148
37
0.139
39
0.132
歐規ClassA
Pin(rms)
(W)
Harmonic
Order
Harmonic
Limits(A)
MeasuredHarmonicCurrent(A)
Results
Pass/Fail
Watts
3
2.3
Iin(rms)(A)
5
1.14
AMP.
7
0.77
9
0.4
11
0.33
13
0.21
15
0.15
17
0.1324
19
0.1184
21
0.1071
23
0.0978
25
0.09
27
0.0833
29
0.0776
31
0.0726
33
0.0628
35
0.0643
37
0.0608
39
0.0577
歐規ClassD
Pin(rms)
(W)
Harmonic
Order
Harmonic
Limits(A)
MeasuredHarmonicCurrent(A)
Results
Pass/Fail
Watts
3
0.465
Iin(rms)(A)
5
0.2598
AMP.
7
0.1368
9
0.0684
11
0.0479
13
0.0405
15
0.0351
17
0.031
19
0.0277
21
0.0251
23
0.0229
25
0.0211
27
0.0195
29
0.0182
31
0.017
33
0.016
35
0.015
37
0.0142
39
0.0135
1-3突入電流(InrushCurrent)
目的:
量測輸入電壓瞬間開啟時,電源供應器之瞬間突入電流
測試環境條件:
溫度25℃,相對濕度65%
測試電氣條件:
1.輸入電壓以產品最大電壓及中心頻率
2.輸出負載以產品規格最大額定電流
3.量測時必須於輸入電壓相位在900or2700測試,量測其瞬間開
啟突入電流
4.冷機及熱機各做一次
結果判定:
以顧客所訂之規格判定
測試設備:
5.AC電源供應器Chroma6560
6.電子負載機Chroma6310
7.儲存式示波器TektronixTDS340A
8.電流探測器TektronixTM502A
9.恆溫恆濕機KSONTHS-B4H+-100
量測結果:
Vin
Iin
1-4輸入電壓瞬斷/保持時間(LineVoltageDropout/Hold-Time)
目的:
量測電源供應器對輸入電壓瞬斷及保持時間之狀態
測試環境條件:
溫度25℃,相對濕度65%
測試電氣條件:
A.輸入電壓瞬斷
1.輸入電壓100Vac/200Vac,50Hz
2.輸出負載以產品規格50%及最大額定電流
3.量測時50%額定電流輸入電壓瞬斷20mS;最大額定電流則輸
入電壓瞬斷10mS
B.保持時間
1.輸入電壓100Vac/47Hz,200V/66Hz
2.輸出負載以產品規格50%及最大額定電流
3.量測時其輸入電壓關機相位在600or2400測試;AC關機與+5V
+3.3V&P.G之保持時間,50%額定電流需20mS,而最大額定
電流需10mS
結果判定:
1.50%額定電流,時間20mS,輸出維持正常工作
2.最大額定電流,時間10mS,輸出維持正常工作
測試設備:
1.AC電源供應器Chroma6560
2.電子負載機Chroma6310
3.儲存式示波器TektronixTDS340A
量測結果:
Vin
DCOUTPUT
+5V,+3.3V,P.GDropoutTimeHold-upTime
1-5降低電壓/恢復(Brownout/Recovery)
目的:
量測電源供應器對於降低電壓及回復之特性影響
測試環境條件:
溫度50℃,相對濕度65%
測試電氣條件:
A.輸入電壓降至0Vac再回升
1.輸入電壓90Vac降至0Vac並回升至90Vac@60Hz,升降條件
為3V/min;264Vac降至0Vac並回升至264Vac@50Hz,升降條
件為6V/min
2.輸出負載以產品規格之最大額定電流
B.輸入電壓降至PSUShut-down,立即回升
1.輸入電壓90Vac降至PSUShut-down立即回升至90Vac
@60Hz,升降條件3V/min;264Vac降至PSUShut-down立即
回升至264Vac@50Hz,升降條件6V/min
2.輸出負載以產品規格之最大額定電流
結果判定:
1.輸入電壓下降點約70Vac,不可低於65Vac
2.輸入電壓上升點約80Vac,不可高於85Vac
測試設備:
1.交流電源供應器Chroma6560
2.電子負載機Chroma6310
3.恆溫恆濕機KSONTHS-B4H+-100
量測結果:
A.
@90Vac
Volts
90
85
80
75
70
65
60
55
50
45
40
35
30
1
25
20
15
10
5
0
3691215182124273033363942454851545760
Time(mm)
@264Vac
Volts
260
250
240
230
220
210
200
190
180
170
160
150
140
1
130
120
110
100
90
80
70
60
50
40
30
20
10
0
3691215182124273033363942454851545760
Time(mm)
B.@90Vac
Volts
90
85
80
75
70
65
60
55
50
45
40
35
30
1
25
20
15
10
5
0
36912151821242730333639424548515457