LED灯带测试报告模板.docx
《LED灯带测试报告模板.docx》由会员分享,可在线阅读,更多相关《LED灯带测试报告模板.docx(61页珍藏版)》请在冰豆网上搜索。
LED灯带测试报告模板
说明:
本测试报告是我们根据LED灯带相关标准整理的报告模板,全部是我们原创,所有工厂或者实验室都可以借鉴使用,可以节省很多时间,因为编制一份模板还是比较难的,很费时间。
这个下载过去,调整一下数据,修改一下公司名称、地址、报告编号、报告日期、产品名称、产品型号、商标、签发日期,这些都修改一下,就可以直接使用,报告的格式我们都按照正规测试报告的格式处理好了,下载即可使用。
XXXXXXXXXXXXXCo.,LTD
TestReport
No:
GLXY190108002R
Page1of21
ProductName
LEDSTRIP
Dateofmanufacture
2018-12-10
Model
6238-S
Batchnumber
——
Manufacture
XXXXXXXXXXXXXCo.,LTD
Samplequantity
5
ManufactureAdd
XXXXXXX
Brand
——
Samplingsite
Warehouse
Inspectiondate
2019-1-7
Inspectionbasis
IEC60598-2-20:
2014Luminaires-Part2-20:
Particularrequirements-Lightingchains
IEC60598-1:
2014+A1:
2017Luminaires-Part1:
Generalrequirementsandtests
Inspectionconclusion
Thisinspection,Inspectionitemsaccordwith
IEC60598-1:
2014+A1:
2017,IEC60598-2-20:
2014Standardrequirements.
Date:
2019-1-9
REMARKS
Sampleparameters:
XXXXX
MainTest:
Auditing:
Approval:
XXXXXXXXXXXXXCo.,LTD
TESTREPORT
No:
GLXY190108002R
Page2of21
IEC60598.1-2014+A1:
2017
Clause
Requirement-Test
Result-Remark
Verdict
4
Generalrequirement
SeeBelow
Lampholdersshallbesodesignedandconstructedthatinnormalusetheyfunctionreliablyandcausenodangertopersonsorsurroundings.
Pass
P
Ingeneral,complianceischeckedbycarryingoutallthetestsspecified.
Pass
P
Inaddition,theenclosureofindependentlampholdersshallcomplywiththerequirementsofIEC60598-1,includingtheclassificationandmarkingrequirementsofthatstandard.
Pass
P
5
Generalconditionsfortests
SeeBelow
5.1
Testsaccordingtothisstandardaretypetests.
Pass
P
NOTE
Therequirementsandtolerancespermittedbythisstandardarerelatedtotestingofatypetestsamplesubmittedforthatpurpose.
Pass
P
Complianceofthetypetestsampledoesnotensurecomplianceofthewholeproductionofamanufacturerwiththissafetystandard.
Pass
P
Inadditiontotypetesting,conformityofproductionistheresponsibilityofthemanufacturerandcanincluderoutinetestsandqualityassurance.
Pass
P
5.2
Unlessotherwisespecified,thetestsaremadeatanambienttemperatureof21°C±5°Candwiththeholdertestedasdeliveredandinstalledasinnormaluse.
18°C
P
5.3
Thetestsandinspectionsarecarriedoutonatotalof
Pass
P
–ninespecimensfornon-switchedlampholders,or
2PCS
P
–12specimensforswitchedlampholders
N/A
N/A
inthefollowingorderofclauses:
N/A
N/A
–threespecimens:
Clauses2to13(exceptfor10.1and11.2)andClauses15to18;
N/A
N/A
–threespecimens:
Clause14(switched-lampholdertestsonly);
N/A
N/A
–threespecimens:
10.1andClauses19and20;
N/A
N/A
–twospecimens:
Clause21(ofwhichonespecimenforthetestof21.1andtheotherforthetestsof21.3or21.4);
N/A
N/A
–onespecimen:
21.5andClause22
N/A
N/A
Fortestinglampholderswitharetentiondevice,theretentiondeviceshallberemoved.
N/A
N/A
XXXXXXXXXXXXXCo.,LTD
TESTREPORT
No:
GLXY190108002R
Page3of21
IEC60598.1-2014+A1:
2017
Clause
Requirement-Test
Result-Remark
Verdict
Fortestinglampholderswitharetentiondeviceaccordingto13.14,threeadditional
specimensarerequiredwiththeretentiondevicekeptinplace.
N/A
N/A
Fortestingofscrewlessterminalsaccordingto11.2,separatespecimensarerequiredinaddition.
N/A
N/A
5.4
Incaseofdoubt,gauges,testcapsandmandrelsareintroducedintothespecimens,unlessotherwisespecified,byapplyingthefollowingtorques:
N/A
N/A
–0,2NmforlampholdersE5;
N/A
N/A
–0,2NmforlampholdersE10;
N/A
N/A
–0,2NmforlampholdersE14;
N/A
N/A
–0,4NmforlampholdersE27;
N/A
N/A
–0,8NmforlampholdersE40.
N/A
N/A
5.5
ForlampholdersE40witharatedcurrentof32A,thetestsshallbebasedonthisratedcurrent.
N/A
N/A
5.6
Lampholdersaredeemedtocomplywiththisstandardifnospecimenfailsinthecompleteseriesoftestsspecifiedin5.3.
Pass
P
Ifonespecimenfailsinonetest,thattestandtheprecedingoneswhichmayhaveinfluencedtheresultofthattestarerepeatedonanothersetofspecimenstothenumberrequiredby
5.3,allofwhichshallthencomplywiththerepeatedtestsandwiththesubsequenttests.
Pass
P
6
Standardratings
SeeBelow
6.1
Standardratedvoltagesare250Vand500V.
250V
P
ForlampholdersE14,andforswitchedlampholdersE27,aratedvoltageof250Vonlyisallowed.
Pass
P
ForlampholdersE5andE10intendedfortheconnectionofseries-connectedlampstothesupply,theratedvoltageshallnotexceed25VforlampholdersE5andnotexceed60Vfor
lampholdersE10.
N/A
N/A
NOTE1
Thesevaluesrefertothevoltagebetweenpartsofdifferentpolarity.ForlampholdersE10intendedfortheconnectionofsinglelampstothesupply,aratedvoltageof250Vonlyisallowed.
N/A
N/A
NOTE2
Theselampholdersarealsousedforsuchspecialcasesasseries-connectedlamps,where,becauseofthelownumberoflamps,60Vperlampholderisexceeded.
N/A
N/A
XXXXXXXXXXXXXCo.,LTD
TESTREPORT
No:
GLXY190108002R
Page4of21
IEC60598.1-2014+A1:
2017
Clause
Requirement-Test
Result-Remark
Verdict
WiththeexceptiongivenforlampholdersE5andE10,theratedvoltageshallbenotlessthan250V.Additionallyaratedvoltageof125VisallowedforlampholdersE40.
N/A
N/A
6.2
Standardratedcurrentsare
Pass
P
–0,2AforlampholdersE5;
N/A
N/A
–0,5AforlampholdersE10;
N/A
N/A
–2AforlampholdersE14;
N/A
N/A
–2Aforswitched-lampholdersE27;
N/A
N/A
–4AforotherlampholdersE27;
Pass
P
–16AforlampholdersE40.
N/A
N/A
Theratedcurrentshallbenotlessthanthestandardvalue.
Pass
P
6.3
LampholdersE40tobeusedon125Vinstallationsmayhaveanadditionalnominalratingof32A.
N/A
N/A
NOTE
Thisnominalratingcoversthevoltagesuptoandincluding130V.
N/A
N/A
6.4
Theratedoperatingtemperatureforlampholdersintendedforuseinhightemperatureconditions(Tmarkedholders)shallbenotlowerthan140°CforlampholdersE14,notlower
than170°CforlampholdersE27andnotlowerthan230°CforlampholdersE40.
190°C
P
NOTE
TheratedoperatingtemperaturesforEdisonscrewlampholderswithoutTmarkingaregiveninIEC60598-1,
N/A
N/A
Theyare
Pass
P
–135°CforlampholdersE14;
N/A
N/A
–165°CforlampholdersE27;
165
P
–225°CforlampholdersE40.
N/A
N/A
7
Classification
SeeBelow
Lampholdersareclassifiedasdefinedin7.1to7.6.
Pass
P
7.1
Accordingtothematerialoftheexternalparts:
Pass
P
–lampholdersofinsulatingmaterial;
N/A
N/A
–metallampholders.
Pass
P
NOTE
Lampholderswithexternalpartsconsistingpartlyofmetalandlampholderscomprisingexternalpartsofinsulatingmaterialwithaconductiveoutersurface,forexampleametallizedoutershell,areconsideredasmetallampholders(see13.3).
Pass
P
XXXXXXXXXXXXXCo.,LTD
TESTREPORT
No:
GLXY190108002R
Page5of21
IEC60598.1-2014+A1:
2017
Clause
Requirement-Test
Result-Remark
Verdict
Thisdoesnotapplytothreadedentriesandexternalparts,forexampleametalshaderingmountedontotheoutsideofalampholderofinsulatingmaterial,whichcannotbecomeliveeveninthecaseofaninsulationfault.Metalholderswithinsulatingcoveringsareconsideredasmetallampholders.
Pass
P
Inordertocheckwhetherornotasurfaceisconductive,twostripe-electrodes1,5mmwide,25mmlongandwithadistanceof2mmfromeachotherareappliedtothesurface(e.g.with
silverconductivepaint).Inaccordancewith15.4,theinsulatingresistanceismeasuredbetweenthestripes.Thesurfaceisconsideredtobeconductiveiftheresistanceislessthan5MΩ.
573MΩ
P
7.2
Accordingtodegreeofprotectionagainstingressofwater:
Pass
P
–ordinarylampholders;
N/A
N/A
–drip-prooflampholders.
Pass
P
7.3
Accordingtomethodoffixing:
Pass
P
–threadedentrylampholders;
N/A
N/A
–cord-griplampholders;
N/A
N/A
–backplatelampholders;
N/A
N/A
–otherlampholders.
Pass
P
NOTE
Examplesofotherlampholdersarelampholdersprovidedwithamechanicalsuspensiondevice,e.g.Ahook.
Pass
P
7.4
Accordingtotype:
Pass
P
–switched-lampholders,providedwithanintegralswitchtocontrolthesupplytothelamp;
N/A
N/A
–non-switchedlampholders.
Pass
P
7.5
Accordingtoprotectionagainstelectricshock:
Pass
P
–unenclosedlampholders;
N/A
N/A
–enclosedlampholders;
N/A
N/A
–independentlampholders;
N/A
N/A
–partlyreinforcedinsulatedlampholders;
N/A
N/A
–enclosedreinforcedinsulatedlampholders.
Pass
P
NOTE
Wherealampholderisusedwithaworkingvoltageof50%orlessofitsmaximumrating,itcanberegardedasequivalenttoareinforcedinsulatedlampholder.
Pass
P
7.6
Accordingtoresistancetoheat:
Pass
P
XXXXXXXXXXXXXCo.,LTD
TESTREPORT
No:
GLXY190108002R
Page6of21
IEC60598.1-2014+A1:
2017
Clause
Requirement-Test
Result-Remark
Verdict
–lampholdersforratedoperatingtemperaturesuptothelimitsgivenin6.4;
Pass
P
–lampholdersforoperatinginhightemperatureconditions(Tmarkedholders).
N/A
N/A
8
Marking
SeeBelow
8.1
Lampholders,otherthanlampholdersE5andE10,shallbemarkedwiththefollowing:
Pass
P
–ratedcurrent,inamperes;
1.8A
P
–ratedvoltage,involts,andratedpulsevoltage,inkV,ifhigherthan
Pass
P
•2,5kVforlampholdersrated250V,
250V/2.5kV
P
•4kVforlampholdersrated500V;
N/A
N/A
Theratedpulsevoltageofthelampholder(inkV)shouldeitherbemarkedo