土木工程英语论文Word格式.docx
《土木工程英语论文Word格式.docx》由会员分享,可在线阅读,更多相关《土木工程英语论文Word格式.docx(6页珍藏版)》请在冰豆网上搜索。
Abuildingiscloselyboundupwithpeople,foritprovidespeoplewiththenecessaryspacetoworkandlivein.Asclassifiedbytheiruse,buildingsaremainlyoftwotypes:
industrialbuildingsandcivilbuildings.Industrialbuildingsareusedbyvariousfactoriesorindustrialproductionwhilecivilbuildingsarethosethatareusedbypeoplefordwelling,employment,educationandothersocialactivities.
Theconstructionofindustrialbuildingsisthesameasthatofcivilbuildings.However,industrialandcivilbuildingsdifferinthematerialused,andinthestructureformsorsystemstheyareused.
Consideringonlytheengineeringessentials,thestructureofabuildingcanbedifinedastheassemblageofthosepartswhichexistforthepurposeofmaintainingshapeandstability.Isprimypurposeistoresistanyloadsappliedtothebuildingandtotransmitthosetotheground.
Intermsofarchitecture,thestructueofabuildingisanddosemuchmorethanthat.Itisaninseparablepartofthebuildingformtovaryingdegreesisageneratorofthatform.Usedskillfully,thebuildingstructurecanestablishorreinforceordersandrhythmsamongthearchitecturevolumesandplanes.Itcanbevisuallydominantorrecessive.Itcandevelopharmoniesorconflicts.Itcanbebothconfiningandemincipating.And,unfortunatelyinsomecases,itcannotbeingored.Itisphysical.
Thestructuremustalsobeengineeredtomaintainthearchitectureform.Theprinciplesandtoolsofphysicsteandmathematicsprovidethebasisfordifferentiatingbetweenrationalandinrationalformsintermsofconstruction.Artistscansometimesgenerateshapesthatobviateanyconsiderationofscience,butarchitectscannot.
Thereareatleastthreeitemsthatmustbepresentinthestructureofabuilding:
stabily,strengthandstiffness,economy.
Takingthefirstofthethreerequiements,itisobviousthatstabilityisneededtomaintainshape.Anunstablebuildingstructureimpliesunbalancedforcesoralackofequilibriumandaconsequentaccelerationofthestructureoritspieces.
Therequirementofstrengthmeansthatthematerialsselectedtoresistthestressesgeneratedbytheloadsandshapesofthestructure(s)mustbeadequate.Indeed,a“factorofsafety”isusuallyprovidedsothatundertheanticipatedloads,agivenmaterialisnotstressedtoalevelevenclosetoitsrupturepoint.Thematerialpropertycalledstiffnessisconsideredwiththerequirementofstrength.Stiffnessisdifferentformstrengthinthatitdirectlyinvolveshowmuchastructurestrainsordeflectsunderload.Amaterialthatisverystrongbutlackinginstiffnesswilldeformtoomuchtobeofvalueinresistingtheforcesapplied.
Economyofabuildingstructurereferstomorethanjustthecostofthematerialused.Constructioneconomyisacomplicatedsubjectinvovlingrawmaterials,fabrication,erection,andmaintenance.Designandconstructionlaborcostsandthecostsofenergyconsumptionmoney(interest)areconsumptionmustbeconsiedered.Speedofconstructionandthecostofmoney(interest)arealsofactors.Inmostdesignsituations,morethanonestructuralmaterialrequiresconsideration.Completivealternativesalmostalwaysexist,andthechoiceisseldomobvious.
Apartformthesethreeprimaryrequirements,severalotherfactorsareworthyofemphasis.First,thestructureorsuctructuralsystemmustrelatetothebuilding’sfunction.Itshouldnotbeinconflictintermsofform.Forexample,alinearfunctiondemandsalinearstructure,andthereforeitwouldbeimpropertoroofabowlingalleywithadome.Similarly,atheatermusthavelarge,unobstructedspansbutafinerestaurantprobablyshouldnot.Statedsimply,thestructuremustbeappropriatetothefunctionitistoshelter.
Second,thestructuremustbefire-resistant.Itisobviousthatthestructuralsystemmustbeabletomaintainitsintegrityatleastuntiltheoccupuantsaresafelyout.Buildingcodesspecifythenumberofhoursforwhichcertainpartsofabuildingmustresisttheheatwithoutcollapse.Thestructuralmaterialsusedforthoseelementsmustbeinherentlyfire-resistantorbeadequentlyprotectedbyfireproofingmaterials.Thedegreeoffireresistancetobeprovidedwilldependuponanumberofitems,includingtheuseandoccupancyloadofthespace,itsdimensions,andthelocationofthebuilding.
Third,thestructureshouldintegratewellwiththebuilding’scirculationsystems.Itshouldnotbeinconflictwiththepipingsystemsforwaterandwaste,theductingsystemsforair,or(mostimportant)themovementofpeople.Itisobviousthatthevariousbuildingsystemsmustbecoordinatedasthedesignprogresses.Onecandesigninasequentialstep-by-stepmannerwithinanyonesystem,butthedesignofallofthemshouldmoveinaparallelmannertowardcompletion.Spatially,allthevariouspartsofabuildingareinterdependent.
Fourth,thestructuremustbepsychologicallysafeaswellasphysicallysafe.Ahighriseframethatswaysconsiderablyinthewindmightnotactuallybedangerousbutmaymakethebuildinguninhabitablejustthesame.Ligheweightfloorsystemsthataretoo“bouncy”canmaketheusersveryuncomfortable.Largeglasswindows,uninterruptedbydividingmotions,canbuquitesafebutwillappearveryinsecuretotheoccupantstandingnexttoon40floorsabovethestreet.
Sometimesthearchitectmustmakedeliberateattemptstoincreasetheapparentstrengthorsolidnessofthestructure.Thisapparentsafetymaybemoreimportantthanhonestlyexpressingthebuilding’sstructure,becausetheuntrainedviewercannotdistinguishbetweenrealandperceivedsafety.
Thebuildingdesignerneedstounderstandthebehaviorofphysicalstructuresunderload.Anabilitytointuitor“feel”structuralbehaviorispossessedbythosehavingmuchexperienceinvolvingstructuralanalysis,bothqualitativeandquantitative.Theconsequentknowledgeofhowforces,stresses,anddeformationsbuildupindifferentmaterialsandshapesisvitaltodevelopmentofthis“sense”.
Structuralanalysisistheprocessofdeterminingtheforcesanddeformationsinstructuresduetospecifiedloadssothatthestructurecanbedesignedrationally,andsothatthestateofsafetyofexistingstructurescanbechecked.
Inthedesignofstructures,itisnecessarytostartwithaconceptleadingtoaconfigurationwhichcanthenbeanalyzed.Thisisdonetomemberscanbesizedandtheneededreinforcingdetermined,inorderto:
a)carrythedesignloadswithoutdistressorexcessivedeformations(serviceabilityorworkingcondition);
andb)topreventcollapsebeforeaspecifiedoverloadhasbeenplacedonthestructure(safetyorultimatecondition).
Sincenormallyelasticconditionswillprevailunderworkingloads,astructuraltheorybasedontheassumptionsofelasticbehaviorisappropriatefordeterminingserviceabilityconditions.Collapseofastructurewillusuallyoccuronlylongaftertheelasticrangeofthematerialshasbeenexceededatcircalpoints,sothatanultimatestrengththeorybasedontheinelasticbehaviorofthematerialisnecessaryforarationaldeterminationofthesafetyofastructureagainstcollapse.Neverthelese,anelastictheorycanbeusedtodetermineasafeapproximationtothestrengthofductilestructures(thelowerboundapproachofplasticity),andthisapproachiscustomarilyfollowedinreinforcedconcretepractice.Forthisreasiononlytheelastictheoryofgtructureispursuedinthischapter.
Lookedatcritically,allstructuresareassembliesofthree-dimensionalelements,theexactanalysisofwhichisaforbddingtaskevenunderidealconditionsandimpossibletocontemplateunderconditionsofprofessionalpractice.Forthisreason,animportantpartoftheanalyst’sworkisthesimplificationoftheactualstructureandloadingconditionstoamodelwhichissusceptibletorationalanalysis.
Thus,astructuralframingsystemisdecomposedintoaslabandfloorbeamswhichinturnframeintogirderscarriedbycolumswhichtransmittheloadstothefoundations.Sincetraditionalstructuralanalysishasbeenunabletocopewiththeactionoftheslab,thishasoftenbeenidealizedintoasystemofstripsactingasbeams.Also,long-handmethodshavebeenunabletocopewiththree-dimensionalframingsystems,sothattheentirestructurehasbeenmodeledbyasystemofplannersubassemblies,tobeanalyzedoneatatime.Themodernmatrix-computermethodshaverevolutionizedstructuralanalysisbymakingitpossibletoanalyzeentriesystems,thusleadingtomorereliablepredictionsaboutthebehaviorofstructuresunderloads.
Actualloadingconditionsarealsobothdifficulttodetermineandtoexpressrealistically,andmustbesimplifiedforpurposesofanalysis.Thus,trafficloadsonabridgestructure,whichareessentiallybothofdynamicandrandomnature,areusuallyidealizedintostaticallymovingstandardtrucks,ordistributedloads,intendedtosimulatethemostsevereloadingconditionsoccurringinpractice.
Similary,continuousbeamsaresometimesreducedtosimplebeams,rigidjointstopin-joints,fillers-wallsareneglected,shearwallsconsideredasbeams;
indecidinghowtomodelastructuresoastomakeitreasonablyrealisticbutatthesametimereasonablysimple,theanalystmustrememberthateachsuchidealizationwillmakethesoulationmoresuspect.Themorerealistictheanalysis,thegreaterwillbetheconfidencewhichitinspires,andthesmallermaybethesafetyfactor(orfactorofignorance).Thus,unlesscodeprovisionscontrol,theengineermustevaluatetheextraexpenseofathoroughanalysisascomparedtopossiblesavingsinthestructure.
Themostimportantus