fuji f9000 diag 命令Word文档格式.docx
《fuji f9000 diag 命令Word文档格式.docx》由会员分享,可在线阅读,更多相关《fuji f9000 diag 命令Word文档格式.docx(14页珍藏版)》请在冰豆网上搜索。
--SramConstantDataTest:
--InterruptsTest:
--SpuriousInterruptsTest:
stdioopenedsuccessfully-bootingsystem
singledisp
Shadowpalette=
084a26c1d73b59ef
FUJIFILMSUMOSSBBoot1.08.
Waitingforslavenoderesponses...
SOMB:
Boot1.08.
STB:
FHMB1:
FHMB2:
SSB:
Application,V4.26.AH
Applicationboot,ctrl-Ctoabort
Timeout
Startingapplication...
stdioopenedsuccessfully-bootingsystem
StartingtheMMI....
GUIStarted.
Startingtheenvironmentmonitor....
Waitingforslavenodestoready
'
startup'
scriptloadedsuccessfully!
Abouttorunscriptstartup(ifpresent).
EnterControl-Ctoabort...
NoControl-Cdetected.
main>
SOMBhasbooted
STBhasbooted
FHMB1hasbooted
FHMB2hasbooted
RequestingFHMB1tobootApplicationCode
RequestingFHMB2tobootApplicationCode
RequestingSTBtobootApplicationCode
RequestingSOMBtobootApplicationCode
PressCtrl-Ctoaborttheapplicationautoboot.
SOMBisrunningApplication
STBisrunningApplication
FHMB2isrunningApplication
FHMB1isrunningApplication
optics_available_beamsis7
TIME:
2847,FriJan2615:
33:
422007
FILE:
read_voltages.cLINE:
204(TEST)
--EXECUTING1006,powersupplytest
243(TESTEND)
--PASSEDTEST:
1006,powersupplytest
2869,FriJan2615:
val_nvram_test.cLINE:
92(TEST)
--EXECUTING1004,nvramintegritytest
2879,FriJan2615:
96(TESTEND)
1004,nvramintegritytest
2891,FriJan2615:
crc_tests.cLINE:
103(TEST)
--EXECUTING1027,checkdisksmountable
++installingscsidriver,unitno0
++calling_CR_chColdStart
++installingscsidriver,unitno1
dfsinitialisedOK
oddfilesysmounted
evenfilesysmounted
generalfilesysmounted
3038,FriJan2615:
442007
120(TESTEND)
1027,checkdisksmountable
3611,FriJan2615:
502007
real_time_clock_test.cLINE:
44(TEST)
--EXECUTING1026,realtimeclocktest
3615,FriJan2615:
48(TESTEND)
1026,realtimeclocktest
StartApplications
MappingallPCIdevices....
StartingScsilogstd....
Startingmediaprocessorcontroller....
Calculatingaodtables......
4channelaodddetected
Booting1040device....
StartingtheSCSItask....
Restoring/Initialisingcassettedatabase....
Startingmediamanagement....
Initialisingtheimagemanager....
restmake_and_load_circling_tables()-res=96000
make_and_load_circling_tables()-res=96000
11382,FriJan2615:
35:
072007
std_Expose_Initialise.cLINE:
189(LOG)
ExposerInitialisationcomplete!
!
●第一个CTRL+C(下载FIRMWARE前,需要停止FIRMWARE的启动)
●第二个CTRL+C(在启动报错的情况下,可以用此方法跳过APPLICATION的启动,直接进入DIAG检测机器)
FIRMWARE版本不一致的情况。
做过registry就可以了,一般不必升级
怎么启动过程信息看出设备所设置使用的激光数目。
三、LOG目录下的命令
●Save_nvram
在哪情况下需要用这个命令?
调校过照排机相关参数的情况下,需要在HDD里做个备份。
●Restore_nvram
●Disp_nvram可以显示NVRAM参数,有时这个参数崩溃了,显示会死机。
在此命令前如使用moreoff可以使NVRAM参数显示连续不会每显一屏就暂停。
把光前显示的NVRAM与出厂软盘里原厂的参数比较,可能发现一些问题。
云南日报维修时机器开机报140错,就是与NVRAM参数不良有关,从HDD恢复备份NVRAM参数修好。
上海某报社NVRAM崩溃了(启动时报NVRAM错,并报823错,其实相关电机和SENSOR经检测都没有问题),许力夫不得不初始化NVRAM后,再按出厂参数一条条输入来修复。
●spin_clean_level
180与120错与cleanlevel有关
如,下面云南日报报错信息
499693,FriJan2612:
34:
302007
spinner_test.cLINE:
499(LOG)
StartingSpinnerContaminationCheck...
508379,FriJan2612:
572007
std_Spinner_Contamination_Check.cLINE:
653(ERROR)
xxxx,Spinnercontaminationlevelis100.0%
508409,FriJan2612:
329(LOG)
MIRRORNEEDSCLEANING!
508413,FriJan2612:
510(LOG)
SpinnerContaminationCheckcomplete.
539705,FriJan2612:
41:
082007
icon.cLINE:
1587(LOG)
Errorreported:
0180
539711,FriJan2612:
1592(LOG)
OPTICS_SPIINER_MIRROR_CONTAMINATED_LEVEL_2
TheSpinnermirrorhasbeenfoundtobe30%contaminatedwithrespecttothecleanreferencelevel.TheRecorderwillstilloperatebutthespinnermirrorshouldbecleanedatthenextservicecall
首先,怀疑光路是不是真的脏了?
可以通过命令来判别
optics>
laser
laser>
read_pow296
Laser_id=2Resolution=96
POD=202.7uWLPD=46.4uWFPD=43.8uW
从LPD与FPD激光功率没有很大变化,可以得出结论:
SPINNER镜面并没有脏,所以这个结果不对。
那么,需要看看SPINNCLEANLEVEL数值了。
diag>
log
Utils>
nvram
nvram>
lcpd_paramspower_controlpunch_scan_margin
set_laser_nocage_creepleak_pie
set_punchbearing_holdpfa_disklog
rd_centre_posnnd_correctioncontam_chk_interval
wr_centre_posnspin_clean_level914_film_set
rd_image_offsetauto_rewind_timescsi_log
wr_image_offsetpunch_bar_width
spin_clean_level
Spinnercleanlevel=0
.
test
sysdiag>
spin
Spinner>
spin_testcontaminationreset_cont_lvllocate_FPDchart_FPD_resp
reset_cont_lvl
Spinnercleanlevel=389
contamination
577781,FriJan2612:
47:
262007
304(TEST)
--EXECUTING1030,readFPDtest
585297,FriJan2612:
48:
412007
338(TESTEND)
1030,readFPDtest
hr
二、SERVICE目录下的命令:
1.OPTICS>
LASER目录下
●read_power
读取在POD和LPD及FPD处的光强,在POD处要得到195uw以上的数值,否则光路有问题。
LPD和FPD处的经验值会在30uw-60uw间,如果低于30uw,可能在胶片上得不到合适的密度。
如果高于35uw则必定在胶片上可以达到3.8以上密度,否则胶片或药水有问题。
这让我想起曾有一家客户的F9000输出胶片上密度过低,只有3.0左右,达不到使用要求。
而FPD可以达到40uw的光强,用户声称换过新的爱比西药水,但没有改善。
但根据对设备的了解,一再坚持要求客户把过期的爱比西药水换为KODAK药水,问题才得以解决。
以前有同志会把它错敲成read_pow961则机器会参数无效而默认成对LD2和96分辨率测量结果如下:
read_powers962
Nonvalidvalueenteredforlaser_id.UsingLD2!
NonvalidvalueenteredforresolutionUsing96res!
Unknownresinconvert_res_monitor_to_rip:
2
Laser_id=2Resolution=2PressCntrlctoexit
laserwarmuptime=200msecs
POD=203.8uWLPD=56.0uWFPD=35.7uWDone
read_powers963
3
Laser_id=2Resolution=3PressCntrlctoexit
POD=204.2uWLPD=56.0uWFPD=35.3uW
如果用READ_POW在POD处只有148代表什么?
没激光或激光太弱,只能检测到150uw以上的数值。
如开机就进入DIAG做READ_POW的情况下,只在POD得到148,是不是说明AODD或AOD或LD或相关同轴电缆中有东西坏了?
有可能,但是应该在做过flin_pow和beam_co之后才能得出推断。
有的机器开机后不做这两步,就有可能在POD得不到正确数值,在发排前会自动做flin_pow和beam_co后,再用read_pow数据就正常了。
所以不要武断确定以上三个备件有损坏,要注意命令之间相互关系。
如果象上面最后一条,FPD功率低于LPD较多(20uw)说明什么?
而如果LPD功率低于FPD较多,又说明什么?
由此,可以知道,用这个命令检测SPINNER是不是脏了,是很有效的。
LD1,LD2光束受SPINNER镜头脏的影响程度可能不一样
正确格式如下:
●Lcpd_par
可以用这个命令来查看激光性能,如果达到d7(最大值)则LD很危险了,但也可能因光路脏造成的。
lcpd_params2
SetupforLD2
NotChangingvalues
ld2ivcga(hex)C0x8e
ld2bias(hex)C0xa2
ld2scandrive(hex)C0x90
ld21.9mWdrive(hex)C0x6b
ld23.8mWdrive(hex)C0xd7
focusnominalpos(dec)C900
NDclearposn(dec)C170
ND2DPOS(dec)C65即做BEAM_CO时对应的NDFILTER的位置
NDMaxTrans(dec)C170最大光强对应ND位置的数值
NDMinTrans(dec)C40最小光强对应ND位置的数值
更换激光器时,要在第一次启动用第二个CTRL+C,进入DIAG再重设置相应的前三行参数。
Ivcge是gain值;
bias就是bias值。
Scandrive手动输入6b,在成功做过beam_co后,这个值会改变,对于老机器,可能高于6b的一个值,对于较新的机器,这个值可能低于6b
此外,LD2的scandrive相应要比LD1和LD3数值大
●Lenable和Ldisable
可以用lenable这个命令打开LD,来对比观察激光管是否工作正常,当然最好配合使用光功率计来测量激光功率
格式:
lenable2drive(或者bias)
Drive对应的是最大光强,bias正相反
●Set_laser_no设置工作的激光数目,但只有在重启动后才生效
2.OPTICS>
AOD目录下的命令
●Flin_pow
◆意义:
频率线性化和功率补偿,如果这个检测不能通过,beam_co肯定会被影响不能通过
◆失败后会报1015错。
当然有时是功率补偿出问题,有时是频率线性化出问题。
可以打开edbg8来观察
●Beam_co
找圆心。
对于LD2以外的激光如LD1或LD3,在相应AODD驱动的AOD的作用下,使光束发生偏转,使其移动到LD2在POD上的位置来作为圆周运动的圆心,这与OPTICS_MMI命令里输出测试片里的coincidencesetting(对应调整finalvalue里AOD0或1的offset参数)都是对圆心的设定,只是精度不同,后者是更精确的校准,是由人为读数输入的,经过的光路更长,前者是机器自动检测。
◆如果这两个检测不能通过,则是致命错误,会发生165错,也会抽白线(丢激光),密度下降等现象。
也可能丢当前文件。
看下例
AODD>
beam_co
beamcocheckpowertol=5
beamcocheckpostolerance=2.000000
beamcopowertol=4
beamcopostolerance=1.600000
Power=226.845809
Power=225.164762
Power=224.031329
Power=222.394855
Power=221.140437
Power=219.682257
Power=218.217708
Power=216.861409
Power=215.492375
Power=214.046929
Power=212.410456
Power=210