Power off and power on procedures for the TS7650 Appliance or TS7650G.docx
《Power off and power on procedures for the TS7650 Appliance or TS7650G.docx》由会员分享,可在线阅读,更多相关《Power off and power on procedures for the TS7650 Appliance or TS7650G.docx(11页珍藏版)》请在冰豆网上搜索。
PoweroffandpoweronproceduresfortheTS7650ApplianceorTS7650G
Poweringoffastand-aloneTS7650serverversion3.1orlater
Poweringoffastand-aloneTS7650serverversion3.1orlater
UsethisproceduretocompletetheTS7650stand-aloneserverpoweroffsequence.
Aboutthistask
Thisistherecommendedmanualpoweroffsequenceforasinglenode(stand-aloneTS7650server) TS7650G or TS7650Appliance server.
Procedure
1.AskthecustomertosuspendI/Ototheserverinthe TS7650G or TS7650Appliance. IndicatebelowwhenthecustomerreportsthatI/Oissuspended.
CustomerreportsthatallI/O
hasbeensuspendedtotheserver
✓
2.Ifthe TS7650G or TS7650Appliance doesnotuseaTSSC,attachakeyboardandmonitortothe TS7650 server.LogonwiththeID ptconfig andthepassword ptconfig toaccessthe ProtecTIERServiceMenu.
3.Fromthe ProtecTIERServiceMenu,selectthe ManageProtecTIERservices option.
4.----------------------------------------------------------------------
5.ProtecTIERServiceMenurunningonrasddx
6.----------------------------------------------------------------------
7.1)ProtecTIERConfiguration(...)
8.2)ManageProtecTIERservices(...)
9.3)HealthMonitoring(...)
10.4)ProblemAlerting(...)
11.5)VersionInformation(...)
12.6)Generateaservicereport
13.7)Generateasystemview
14.8)UpdateProtecTIERcode
15.
16.E)Exit
17.----------------------------------------------------------------------
>>>Yourchoice?
18.Fromthe ManageProtecTIERservices menu,select Stopallservices.
19.----------------------------------------------------------------------
20.ProtecTIERServiceMenurunningonrasddx
21.ManageProtecTIERServices(...)
22.----------------------------------------------------------------------
23.1)Displayservicesstatus
24.2)Startallservices
25.3)Stopallservices
26.4)StopProtecTIERservicesonly(includingGFS)
27.
28.B)Back
29.E)Exit
30.----------------------------------------------------------------------
>>>Yourchoice?
31.Whentheservicesarestopped,thesystemshowsthefollowingmessages:
32.Stoppingptrasd[Done]
33.Stoppingvtfd[Done]
Stoppingptcluster[Done]
34.PressEntertoreturntothe ProtecTIERServiceMenu,thentype E toexitfromthe ProtecTIERServiceMenu.
35.LogintotheserverwiththeuserID ptadmin,andthepassword ptadmin.
Theservercommandlinedisplays.
36.Fromtheservercommandline,type poweroff andpressEnter.
Whenthepoweroffprocessescomplete,thepowerLEDontheserver'sfrontpanelblinkssteadily.Thisindicatestheserverisinstandbymode.
37.Poweroffallattachedstoragecontrollersthatarelocatedintheframewiththeserver,orinaseparatestorageframe.Thecontrolunitsmustbepoweredoffbeforetheexpansiondrawers.Ifmultiplecontrollersarepresent,powerthemalloff.
CAUTION:
Seestoragecontroller/expansionunitdocumentationfordetailedpoweroffinstructionstopreventdamagetothecontrollersandexpansiondrawerunits.
38.Whenthecontrollershavefinishedpoweringoff,poweroffallexpansionunits.
39.ShutdowntheTSSC.Todoso:
a.LogintotheTSSCwiththeusername:
service andpassword:
service.
b.Right-clickontheTSSC'sbluedesktop.The TS3000SystemConsoleMenu displays.
c.Select ShutdownConsole.
d.Adialogboxappearswiththisquestion:
Shutdownthemachine?
e.Select OK tostarttheshutdownprocess.
f.Theshutdownprocessiscompletewhenyouseethis:
ItisnowsafetoturnofftheTS3000SystemConsoleHolddownthepowerbuttonfor5secondstopoweroff.
Pressthepowerbutton,itisnotnecessarytoholdthebuttondown.
g.Whenthepoweroffprocessiscomplete,thepowerLEDontheserver'sfrontpanelwillblinksteadily.Thisindicatesthattheserverisinstandbymode.
40.Whenallrelevantcomponentsintheframe(orframes)arepoweredoff,powerofftheframe(orframes)usingtheUnitPowerOn/Off(UPO)switchorthecustomer'scircuitbreaker.
Poweringonastand-aloneTS7650serverversion3.1orlater
Poweringonastand-aloneTS7650serverversion3.1orlater
UsethisproceduretocompletetheTS7650stand-aloneserverpoweronsequence.
Aboutthistask
Thisistherecommendedmanualpoweronsequenceforasinglenode(stand-aloneTS7650server) TS7650G or TS7650Appliance server.
Procedure
1.Usingtheframe'sUPOswitchorthecustomer'scircuitbreaker,restorepowertotheframe(orframes).
2.Poweronallexpansionunits.
3.Poweronallstoragecontrollers.
4.PressthepowerbuttonontheTSSC.
5.LogintotheTSSCwiththeusername service andpassword service.
6.Pressthepowerbuttonontheserver'sfrontpanel.
Approximately15minutesaftertheserverispowered-on,followingthereboot,youcanlogintothe ProtecTIERServiceMenu.
7.Accessthe ProtecTIERServiceMenu withamonitorandkeyboardpluggedintothe TS7650 server.LoginwiththeIDptconfig andthepassword ptconfig.
8.Fromthe ProtecTIERServiceMenu,selectthe ManageProtecTIERservices option.
9.----------------------------------------------------------------------
10.ProtecTIERServiceMenurunningonrasddx
11.----------------------------------------------------------------------
12.1)ProtecTIERConfiguration(...)
13.2)ManageProtecTIERservices(...)
14.3)HealthMonitoring(...)
15.4)ProblemAlerting(...)
16.5)VersionInformation(...)
17.6)Generateaservicereport
18.7)Generateasystemview
19.8)UpdateProtecTIERcode
20.
21.E)Exit
22.----------------------------------------------------------------------
>>>Yourchoice?
23.Fromthe ManageProtecTIERservices menu,select Displayservicesstatus.
24.----------------------------------------------------------------------
25.ProtecTIERServiceMenurunningonrasddx
26.ManageProtecTIERServices(...)
27.----------------------------------------------------------------------
28.1)Displayservicesstatus
29.2)Startallservices
30.3)Stopallservices
31.4)StopProtecTIERservicesonly(includingGFS)
32.
33.B)Back
34.E)Exit
35.----------------------------------------------------------------------
>>>Yourchoice?
36.Waituntilthedisplayshowsalltheserviceshavestarted.
37.Thestand-alone TS7650 serverpoweronprocessiscomplete.
Poweringoffthe ProtecTIER server version2.5orearlier
Poweringoffthe ProtecTIER server version2.5orearlier
Completethetaskinthistopictoturnoffallthecomponentsofthe ProtecTIER® server V2.5orearlier.
Thissectionprovides tasks forturningoffallcomponentsofthe TS7650Appliance orthe TS7650G inbothstand-aloneandclusteredinstallations.Thissectionalsoprovidesinformationaboutthefollowingrelatedtopics.
∙Performinganemergencyshutdown
∙Additionalpowerinformation
Toturnoffallcomponentsinthe TS7650Appliance orthe TS7650G inbothstand-aloneandclusteredinstallations,performthefollowingsteps:
1.Ensurethatnodrivefaultlight-emittingdiodes(LEDs)arelitonalldiskcomponents.IfanydrivefaultLEDsarelit,correctthefaultbeforecontinuing.
2.AskthecustomertosuspendI/Ototheserverinthe TS7650Appliance orthe TS7650G inbothstand-aloneandclusteredinstallations.IndicatebelowwhenthecustomerreportsthatI/Oissuspended.
CustomerreportsthatallI/O
hasbeensuspendedtotheserver
✓
3.Turnofftheserverbyperformingthefollowingsubsteps:
a.Openasecureshell(SSH)sessionwiththeserverusingoneofthefollowingmethods:
UsingTerminalonthesystemconsole:
i.Right-clickthesystemconsoledesktopandthenclick Terminal.
ii.AttheTerminalcommandprompt,enterthecommand tsys andselectthesystemtowhichyouwanttoconnectortypethefollowingcommand:
sshptadmin@xxx.xxx.xxx.xxx
where xxx.xxx.xxx.xxx istheserverIPaddress,andthenpressthe Enter key.
iii.Atthe password prompt,type ptadmin andthenpressthe Enter key.
iv.Gotostep 3.b.
Usingadirectconnectionthroughtheattacheduniversalserialbus(USB)keyboardandmonitor:
v.ConnectaUSBkeyboardandmonitortothebackoftheserver.
vi.Attheloginprompt,loginwiththeuserID root andthepassword admin.
vii.Atthecommandprompt,typethefollowingcommand:
poweroff
viii.Gotostep 4.
b.AttheSSHcommandprompt,typethefollowingcommand:
poweroff
Thisactiondismountsthefilesystemandshutsdowntheservertostandbymode.
4.Ensurethattheserverhasshutdowntostandbymodebyverifyingthatthepower-onLEDontheoperatorinformationpanelonthefrontoftheserverisflashing.See Figure1.
Figure1.Serveroperatorinformationpanel
5.Ifinatwo-nodeenvironment,repeatsteps 3 and 4 fortheotherserverinthenode.
6.Turnoffbothpowersupplyswitchesonthebackofthediskcontrollerorcontrollers.
7.Turnoffbothpowerswitchesonthebackofalldiskexpansionmodulesconnectedtothediskcontrollerorcontrollers.
8.Verifythatnoexternalsystemsareconnectedtoframepowersupplies.
9.SettheEmergencyPowerOff(EPO)switchonthefrontoftheframeorracktotheOFF(○)position.
Poweringonthe ProtecTIER server version2.5orearlier
Poweringonthe ProtecTIER server version2.5orearlier
Completethistasktopoweronthe ProtecTIER® server V2.5orearlier.
Aboutthistask
Thissectionprovidestasksforturningonallcomponentsofthe TS7650Appliance orthe TS7650G inbothstand-aloneandclusteredinstallations.
Procedure
Toturnonallcomponentsinthe TS7650Appliance orthe TS7650G,performthefollowingsteps:
1.Verifythefollowing:
∙Alldataandpowe