Features:
1)DXL360S/C:
Highaccuracy±0.05°,highresolution0.01°
DXL360:
±0.1°,resolution0.02°,detailcheckspecification
2)DualandSingleaxiswithuserfriendlyLCDdisplayangle
3)Rechargeable
4)VShapemetalcaseforeasytofitatthecornerorpipe.
5)5SideMagneticbase
6)Audiblealarmingatsettableanglerange
7)Anyanglemeasurement*DXL360s/conly
8)USB/BluetoothtopcconnectionneedadapterforDXL360andDXL360s/c.
Specifications
Accuracy:
DXL360S/C:
0to20°:
±(0.05°)
20to70°:
±(0.1°)
70to90°:
±(0.05°)
DXL360:
0to20°:
±(0.1°)
20to70°:
±(0.2°)
70to90°:
±(0.1°)
*AfterCalibrated
Measuringrange:
Singleaxis:
360°,Dualaxis:
±40°
Resolution:
DXL360S/C:
0.01°
DXL360:
0.02°
AnyAngleMeasurement0.5°
Accuracy*DXL360s/c:
GyroRotationSpeed*DXL360s/c:
<50°/s
Responsetime:
<0.4second
Audiosound:
60dB@30cm
Zerooffsetdriftangleper°C:
0.0058°(typical)
Operatingtemperature:
0to50°C
Storagetemperature:
-10to60°C
UserInterface:
Mono-colorLCDwithbacklight
SupplyPower:
RechargeableLi-Polymer3.7V
Chargerport:
5V500mAMinitype-BUSBport
PowerConsumption:
Standby:
10uA,Operation:
20mA.
StandbyBatteryLife:
4000hours
OperatingBatteryLife:
40hours
Dimensions(inmm):
70(L)x70(W)x23(H)
MagneticBase:
affixat4corner
MagneticForce:
N48
Weight:
120gram
ButtonFunctions
Button
FunctionDescriptions
NormalMode
MENUMode
POWER
Innormaloperation,thisbuttonturnsthedeviceON/OFF.
Servesastheescapekeyatmenumode
ZERO
Whenpressed,thecurrentreadingissettozero;subsequentmeasurementsarerelativetothisreading.TheLCDwillshowthe
icontoindicatethedeviceisinzeromode.
Pressandholdfor3secondstoenableordisablesound.The
icononLCDwillbedisplacedaccordingly.Thebuzzeralarmingcouldbesetatdifferentaccuracylevel.Refertosection“AngleAlarming”.
Servesastheupwardkeyforoptionselection.
HOLD
Whenpressed,thecurrentvaluewillfreeze;theuniticon
flashestoindicatethereadingisonhold.
Servesasthedownwardkeyatmenumode
SET
Pressandholdfor3secondstoenterMENUmode,forsetmodeoptions.
ServesastheSetkey.
ANGLE*DXL360S/Conly
Anyanglemeasurementstartbutton.Refertosection“AnyAngle”
Pressandholdfor3secondstoenterMENUmode,forsetmodeoptions.
ServesastheSetkey.
LCDIconsRepresentations
Batterystatusindicationicons
Theseiconsindicatethebatterylevel.Thereare3levelsrepresentingempty,halfandfull.
Indual-axismode,theLCDdisplaysthedirectionoftiltgraphically.ItwillshowasEbubbletodisplaythedirectionoftilt
Degreemode.FlashwhenunitisinHOLDmode
mm/M,theheightofoneendfor1mlongplate.
*DXL360S/COnly
Gradient%mode.FlashwhenunitisinHOLDmode
Soundnotificationon.
Blankasoff
Showthislogoasrelativevalueisshowing.WhentheZerobuttonispressed,theunitresetcurrentangletozero.
Directionoftilticons,showthetiltangledirection
Dual-AxisMode.BoththeXandYaxisanglewillbeshowed.Dualaxismodemeasuresinclinationupto+-40degreeforeachaxisbeforeitautomaticallyswitchtosingleaxismode.
SingleAxisMode.Measureslopeupto+-90degree.
Thetriangleiconindicatesthedirectionoftiltwithrespecttothebottomrightcorneroftheunit.
BatteryCharging
IthasabuiltinLithiumIonrechargeablebattery.Astandardchargerissuppliedthattheinputvoltageis110Vto240VAC,50/60Hz,andtheoutputis5VDC,500mA.Thechargeroperatingprocedureislistbelow:
1)PlugtheChargerintoACsocket,theREDindicatoronthechargershouldturnedON,
2)PlugtheUSBchargingcabletotheCharger,
3)InserttheotherendoftheUSBcabletotheunit,
4)ThebatteryiconontheLCDblinkstoindicatecharginginprocess.Uponchargingcomplete,theiconstopsblinking.
5)Thechargingtimeisapprox.3hours.
TheunitcouldalsobechargedbyconnectingtheUSBcabletotheunitandacomputer’sUSBport.Thishasthesameeffectwhenchargingtheunitwiththeprovidedadaptor.
Note:
WhentheunitisturnedOFF,andplugintheUSBchargecable,theLCDwillnoshowanything,itisNORMAL.OncetheunitisturnedON,thebatteryiconshouldflashindicatingtheunitisinchargingmode.
Relative/AbsoluteMeasurement
RelativeMeasurement
LCDIcon:
AbsoluteMeasurement
LCDIcon:
Blank
RelativeandAbsoluteModeSwitching:
1Pressandreleasethe“ZERO”keytosettherelativemeasurementzeropoint
2Pressandreleasethe“ZERO”keytocanceltherelativezeropointandbacktoabsolutemeasurementmode.
HoldFunction
HoldingMode:
LCDIconblinking:
Holdingfunction:
1.Pressandreleasethe“HOLD”keytoactivateholdingfunction,digitwillfreeze.
2.Pressandreleasethe“HOLD”keytocanceltheholdingfunction.
AutoPowerOff
Fornomovementin30minutes,theunitwillpoweroff.
Orwecansettoneversleepmodeatbelowinstruction.
Powerautooffsetting:
1.Pressandhold“SET”/“ANGLE”keyandenterMENUmode
2.Select“POWER”by“ZERO”and“HOLD”key,press“SET”keytoenterPowermode
3.Scroll“NEVER”or“30MIN”by“ON/OFF”and“HOLD”key
4.Press“SET”keytoconfirmNEVERor30MIN(30minutes)sleep
RestoreFactorySetting
Whenyoufindthattheunitisabnormal,youcanrestoretheunittofactorysetting.
Allcalibrationsettingwillberestoredtofactorysetting.
*Notsuggestrestoretofactorysettinginnormalstatus,foraccuracydrift,pleasefollowCalibration.Afterfactoryset,pleaseredocalibrationtoensuretheaccuracy.
Restoretofactorysetting:
1.Pressandhold“SET”/“ANGLE”keyandenterMENUmode
2.Select“FACTORYSET”by“ZERO”and“HOLD”key,press“SET”keytoenterFACTORYSETmode
3.Scroll“YES”or“NO”by“ZERO”and“HOLD”key
4.Press“SET”keytoconfirm
AngleAlarming
AlarmingMode:
LCDIcon:
AlarmingAnglesetting:
1.Pressandhold“SET”/“ANGLE”keyandenterMENUmode
2.Select“BUZZER”by“ZERO”and“HOLD”key,press“SET”or“ANGLE”keytoenterBUZZERsetting
Pressandhold“ZERO”and“HOLD”keyforfastscrollingthedigit.
3.Press“SET”or“ANGLE”toentersettingvalue
SINGLE
Vertical/Singleaxismodealarmingangle(Degree)
DUAL.X
Horizontal/DualaxismodeXaxisalarmingangle(Degree)
DUAL.Y
Horizontal/DualaxismodeYaxisalarmingangle(Degree)
RANGE
Therange(Degree)thatwilltriggertheaudiblealarming
Forexample:
SINGLE.setto20.00
RANGEsetto01.00
Whiletheunitisin+19°to+21°or-19°to-21°,theunitwillalarm
ACTIVE
INorOUTtosetthealarmwillalarminofrangeoroutofrange
Calibration
Calibratetheunit,onceyoufoundthatthereisaccuracydriftontheunit.Youcanverifytheaccuracyatbelowstep:
AtStep1,youmeasuredXandYvalue,X1andY1
AtStep2,youmeasuredX2andY2,intheoryX1=-X2,Y1=-Y2.
Iftheerroristoolarge,youcanentercalibrationmodetoeliminatetheerror
Accuracydriftiscausingbylargeambienttemperaturechange(5to10DegreeCelsius)ortheunithasbeendropped.
CalibrationProcedure:
Step1:
Pressandholdthe“SET”or“ANGLE”keyenterMenumode.Select“Calibration”mode,press“SET”.Placetheunitonaflattable(noneedperfectleveltable)
LCDdisplay“CALIBRATEDUALAXISPRESSSET”,press“SET”andbuzzerwillbeep;waituntilthebeepsoundstop.Whilethebuzzerisbeepingkeeptheunitstable.
Step2:
Thenrotatetheunit180degreewiththeothersideagainstthesameplace.PresstheSetbuttonagain,andwaitforthebeepfinished.
Step3:
LCDdisplay“CALIBRATEHORIZONTALPRESSSET”.Placetheunithorizontallikethepicture“STEP3”andthenpress“SET”,waituntilthebeepsoundstop.
Step4:
Thenrotatetheunit180degreeatthesameplace.Pressthe“ZERO”buttonagain,andwaitforthebeepfinished.
Step5:
LCDdisplay“CALIBRATEVERTICALPRESSSET”,mentionthattheON/OFFKeyatupperside,holdonaflatwall.Andthenpress“SET”Key.Waitforthe“Beep”soundstop.
Step6:
Thenrotatetheunit180degreewiththeothersideagainstthesameplaceofwall(ON/OFFKeyatupperside).PresstheSetbuttonagain,andwaitforthebeepfinished.Now,theLCDshouldgobacktotheselectionmenu.Thecalibrationisdone,byselecting“Back”togobackfornormaloperation
ANYANGLEmeasurement:
*DXL360S/Conly
Anyanglemeasurementisusinggyrotechnique.
Youcanmeasuretheanglebetweentwofaces,notonlyinearthgravitydirection.
1)PressAnglekeyatthefirstface,andthenrotateslowlyandmustkeeptherotationaxistoanothertestingface
2)Itwillthenshowtheangleonceyounotmovetheunit.
Therotationaxis:
AnyAngleMeasurementMethod:
Example:
Measureanglebetweentwowoodenwallsis88.9°
CalibrateGyro*DXL360S
1)PlaceUnitAtFlatTableAndthenPressSet
2)Flip360degreeinclockwiseandthenpressset
Pleaserotateslowlytoincreasetheaccuracy
3)Placeunitatflattableandthenpressset
4)Flip360degreecounterclockwiseandthenpressset
Pleaserotateslowlytoincreasetheaccuracy
PCCommunication
IthasaPCdataloggingfunction.
ForDXL360SCyoucandirectlyplugtheUSBcablebetweenPCandprotractorbyminiUSBcable
ForDXL360/SYoucannotdirectlyplugtheUSBcablebetweenPCtoprotractorbyageneralUSBcable.
YouneedtooptionalpurchasethePCadapterSVRS232
YoucancontinuetodataloggingXandYinclinationdatatoPC.
Samplingtimeisaround2Hz.
Specification:
1)RS232ComPort9600baudrate
2)USBconnection(includeaRS232toUSBadapter)
3)FormatwilloutputAS