柱底均匀反力q=R/An=2.42N/mm^2
M=0.5*q*(0.5*a)^2=12100N*mm
=18.3mm,实际取20mm
(3)加劲板假定厚度为12mm,焊脚高度为6mm,焊缝长度为550mm。
剪力
=61.215KN,弯矩
=9.18KN*m
则竖向连接角焊缝中应力为
=61215/(0.7*6*(550-2*6-15)=27.87N/mm^2
=6*9180000/(0.7*6*(550-2*6-15)^2)=47.94N/mm^2
=48.18N/mm^2,满足要求
2.上弦节点
(1)腹杆与节点板的焊缝(K1=0.7,K2=0.3;焊缝高度6mm):
肢背:
=0.7*318.15/(2*0.7*6*140)=189.38mm,实际取210mm,
肢尖:
=0.3*318.15/(2*0.7*6*140)=81.16mm,实际取100mm;
肢背:
=0.7*230.37/(2*0.7*6*140)=137.13mm,实际取150mm,
肢尖:
=0.3*230.37/(2*0.7*6*140)=58.77mm,实际取80mm;
肢背:
=0.7*175.47/(2*0.7*6*140)=104.45mm,实际取120mm,余同
肢尖:
=0.3*175.47/(2*0.7*6*140)=44.76mm,实际取70mm;余同
(2)弦杆与节点板的焊缝
计算该节点时,应考虑上弦杆内力与集中荷载的共同作用,为连接方便一般角钢肢背采用槽焊,肢尖采用角焊缝,计算时采用以下近似假设:
A、弦杆角钢肢背槽焊缝承受节点荷载P,槽焊缝按两条角焊缝hf1=0.5t计算(图8):
=42200/(2*0.7*6*140)=35.88N/mm^2<136.64N/mm^2
B、弦杆角钢肢尖的两条角焊缝承担相邻弦杆的内力差
=306.16KN及其产生的偏心矩
=19.14KN*m
=306160/(2*0.7*6*400)=91.12N/mm^2
=6*19140000/(2*0.7*6*400*400)=67.51N/mm^2
=106.61N/mm^2<140N/mm^2,满足要求
3.下弦节点
腹杆焊缝同上弦,弦杆与节点板的焊缝无外荷载时仅受相邻节间内力差
=220.07KN,具体计算如下:
肢背:
=0.7*220070/(2*0.7*6*140)=131.0mm,实际取150mm(余同)
肢尖:
=0.3*220070/(2*0.7*6*140)=56.14mm,实际取150mm(余同)
4.屋脊节点
此节点处左右弦杆断开,需要拼接件拼接。
拼接件一般与上弦杆同截面,同时将角钢的棱角截去并把竖向肢的部分切除。
(1)拼接计算
拼接角钢与受压弦杆的连接按最大受压弦杆内力计算,每边共有4条焊缝平均承担此力,
因而焊缝长度为
=488470/(4*0.7*6*140)=207.70mm,
则拼接角钢长度:
ls=2(lw+2hf)+20=460mm
(2)弦杆与节点板的连接焊缝
计算时假定节点力P由上弦角钢肢背的槽焊缝承担,按
=42200/(2*0.7*6*207)=24.27N/mm^2<0.8*1.22*140=136.64N/mm^2
满足要求;
肢尖的受力按上弦内力的15%计算,并计入其产生的弯矩
=0.15*488470/(2*0.7*6*207)=42.14N/mm^2
=0.15*488470*70/(2*0.7*6*207*207)=14.25N/mm^2
=43.73N/mm^2<140N/mm^2
满足要求。
5.下弦拼接节点
此节点处左右弦杆断开,需要拼接件拼接:
与下弦杆同截面,将角钢的棱角截去并把竖向肢的部分切除。
(1)拼接计算
拼接角钢与下弦杆角钢共有4条焊缝,按截面的抗拉强度承载力
=5480*140=767200N进行连接计算:
=767200/(4*0.7*6*1400)=326mm
拼接角钢长度:
ls=2(lw+2hf)+20=700mm
(2)连接焊缝
下弦与节点板连接焊缝受力N按下弦较大内力的15%和两侧下弦的内力差两者中较大值56.43KN来计算。
肢背:
=0.7*56430/(2*0.7*6*140)=33.60mm,实际取340mm
肢尖:
=0.3*56430/(2*0.7*6*140)=14.40mm,实际取340mm
综上,所有屋架体系计算书,其结果均满足设计要求。
详屋架详图及节点图。