1、电子秤文献翻译Intelligent Data Acquisition SystemEngineers often must monitor a handful of signals over extended periods of time, and then graph and analyze the resulting data. The need to monitor, record and analyze data arises in a wide range of applications, including the design-verification stage of pr
2、oduct development, environmental chamber monitoring, component inspection, benchtop testing and process trouble-shooting.This application note describes the various methods and devices you can use to acquire, record and analyze data, from the simple pen-and-paper method to using todays sophisticated
3、 data acquisition systems. It discusses the advantages and disadvantages of each method and provides a list of questions that will guide you in selecting the approach that best suits your needs.IntroductionIn geotechnical engineering, we sometime encounter some difficulties such as monitoring instru
4、ments distributed in a large area, dangerous environment of working site that cause some difficulty for easy access. In this case, operators may adopt remote control, by which a large amount of measured data will be transmitted to a observation room where the data are to be collected, stored and pro
5、cessed. The automatic data acquisition control system is able to complete the tasks as regular automatic data monitoring, acquisition and store, featuring high automation, large data store capacity and reliable performance. The system is composed of acquisition control system and display system, wit
6、h the following features: 1. No. of Channels: 32 ( can be increased or decreased according to users real needs.)2. Scanning duration: decided by user, fastest 32 points/second3. Store capacity: 20G( may be increased or decreased)4. Display: (a) Table of parameter (b) History tendency (c) Column grap
7、hics.5. Function: real time monitoring control, warning 6. Overall dimension: 50cm50cm72cmData acquisition systems, as the name implies, are products and/or processes used to collect information to document or analyze some phenomenon. In the simplest form, a technician logging the temperature of an
8、oven on a piece of paper is performing data acquisition. As technology has progressed, this type of process has been simplified and made more accurate, versatile, and reliable through electronic equipment. Equipment ranges from simple recorders to sophisticated computer systems. Data acquisition pro
9、ducts serve as a focal point in a system, tying together a wide variety of products, such as sensors that indicate temperature, flow, level, or pressure. Some common data acquistion terms are shown below:Data acquisition technology has taken giant leaps forward over the last 30 to 40 years. For exam
10、ple, 40 years ago, in a typical college lab, apparatus for tracking the temperature rise in a crucible of sodiumtungsten- bronze consisted of a thermocouple, a bridge, a lookup table, a pad of paper and a pencil. Todays college students are much more likely to use an automated process and analyze th
11、e data on a PC Today, numerous options are available for gathering data. The optimal choice depends on several factors, including the complexity of the task, the speed and accuracy you require, and the documentation you want. Data acquisition systems range from the simple to the complex, with a rang
12、e of performance and functionality.Pencil and paperThe old pencil and paper approach is still viable for some situations, and it is inexpensive, readily available, quick and easy to get started. All you need to do is hook up a digital multimeter (DMM) and begin recording data by hand.Unfortunately,
13、this method is error-prone, tends to be slow and requires extensive manual analysis. In addition, it works only for a single channel of data; while you can use multiple DMMs, the system will quickly becomes bulky and awkward. Accuracy is dependent on the transcribers level of fastidiousness and you
14、may need to scale input manually. For example, if the DMM is not set up to handle temperature sensors, manual scaling will be required. Taking these limitations into account, this is often an acceptablemethod when you need to perform a quick experiment.Strip chart recorderModern versions of the vene
15、rable strip chart recorder allow you to capture data from several inputs. They provide a permanent paper record of the data, and because this data is in graphical format, they allow you to easily spot trends. Once set up, most recorders have sufficient internal intelligence to run unattended without
16、 the aid of either an operator or a computer. Drawbacks include a lack of flexibility and relatively low accuracy, which is often constrained to a few percentage points. You can typically perceive only small changes in the pen plots. While recorders perform well when monitoring a few channels over a
17、 long period of time, their value can be limited. For example, they are unable to turn another device on or off. Other concerns include pen and paper maintenance, paper supply and data storage, all of which translate into paper overuse and waste. Still, recorders are fairly easy to set up and operat
18、e, and offer a permanent record of the data for quick and simple analysis.Scanning digital multimeterSome benchtop DMMs offer an optional scanning capability. A slot in the rear of the instrument accepts a scanner card that can multiplex between multiple inputs, with 8 to 10 channels of mux being fa
19、irly common. DMM accuracy and the functionality inherent in the instruments front panel are retained. Flexibility is limited in that it is not possible to expand beyond the number of channels available in the expansion slot. An external PC usually handles data acquisition and analysis.PC plug-in car
20、dsPC plug-in cards are single-board measurement systems that take advantage of the ISA or PCI-bus expansion slots in a PC. They often have reading rates as high as 100,000 readings per second. Counts of 8 to 16 channels are common, and acquired data is stored directly into the computer, where it can
21、 then be analyzed. Because the card is essentially part of the computer, it is easy to set up tests. PC cards also are relatively inexpensive, in part, because they rely on the host PC to provide power, the mechanical enclosure and the user interface. Data acquisition optionsIn the downside, PC plug
22、-in cards often have only 12 bits of resolution, so you cant perceive small variations with the input signal. Furthermore, the electrical environment inside a PC tends to be noisy, with high-speed clocks and bus noise radiated throughout. Often, this electrical interference limits the accuracy of th
23、e PC plug-in card to that of a handheld DMM .These cards also measure a fairly limited range of dc voltage. To measure other input signals, such as ac voltage, temperature or resistance, you may need some sort of external signal conditioning. Additional concerns include problematic calibration and o
24、verall system cost, especially if you need to purchase additional signal conditioning accessories or a PC to accommodate the cards. Taking that into consideration, PC plug-in cards offer an attractive approach to data acquisition if your requirements fall within the capabilities and limitations of t
25、he card.Data loggersData loggers are typically stand-alone instruments that, once they are setup, can measure, record and display data without operator or computer intervention. They can handle multiple inputs, in some instances up to 120 channels. Accuracy rivals that found in standalone bench DMMs
26、, with performance in the 22-bit, 0.004-percent accuracy range. Some data loggers have the ability to scale measurements, check results against user-defined limits, and output signals for control. One advantage of using data loggers is their built-in signal conditioning. Most are able to directly me
27、asure a number of different inputs without the need for additional signal conditioning accessories. One channel could be monitoring a thermocouple, another a resistive temperature device (RTD) and still another could be looking at voltage. Thermocouple reference compensation for accurate temperature
28、 measurement is typically built into the multiplexer cards. A data loggers built-in intelligence helps you set up the test routine and specify the parameters of each channel. Once you have completed the setup, data loggers can run as standalone devices, much like a recorder. They store data locally
29、in internal memory, which can accommodate 50,000 readings or more.PC connectivity makes it easy to transfer data to your computer for in-depth analysis. Most data loggers are designed for flexibility and simple configuration and operation, and many provide the option of remote site operation via bat
30、tery packs or other methods. Depending on the A/D converter technique used, certain data loggers take readings at a relatively slow rate, especially compared to many PC plug-in cards. Still, reading speeds of 250 readings/second are not uncommon. Keep in mind that many of the phenomena being monitor
31、ed are physical in nature such as temperature, pressure and flow and change at a fairly slow rate. Additionally, because of a data loggers superior measurement accuracy, multiple readings and averaging are not necessary, as they often are in PC plug-in solutions. Data acquisition front endsData acqu
32、isition front ends are often modular and are typically connected to a PC or controller. They are used in automated test applications for gathering data and for controlling and routing signals in other parts of the test setup. Front end performance can be very high, with speed and accuracy rivaling t
33、he best standalone instruments. Data acquisition front ends are implemented in a number of formats, including VXI versions, such as the Agilent E1419A multifunction measurement and control VXI module, and proprietary card cages. Although front-end cost has been decreasing, these systems can be fairly expensive,
copyright@ 2008-2022 冰豆网网站版权所有
经营许可证编号:鄂ICP备2022015515号-1