1、电性能测试报告电 性 能 测 试 报 告Electronic Performance Test Report样机名称(type)样机型号 (Model)样机版本(version)LED驱动器(LED Driver)EWP200C1050LED4PRev1.0.1拟制(Tested by)黄秋霞(Qiuxia Huang)日期(Date)2015-10-16审核(Approved by)Marey日期(Date)1 概述. 3(Summary)2 测试地点、时间、人员. 3(Test place, Time, Personnel)3 测试引用标准. 3(Guide)3.1 技术指标要求 . 3(
2、Technical Norm Requirement)3.2 测试方法 . 3(Test Criterion)4 测试设备. 3(Test Equipment)5 结论. 3(Test Result)6 问题报告. 3(Problem Report)7 测试容和结果. 4(Test Items and Result)7.1 常温环境电气性能测试 . 4(Electronic performance Test at Normal Temperature)7.2 高温环境电气性能测试 . 5(Electronic performance Test at High Temperature)7.3 低
3、温环境电气性能测试 . 6(Electronic performance Test at Low Temperature)8 附录. 7(Appendix)8.1 输出电流测试值 . 7(Output Current Test Values)8.2 效率测试数据记录 . 7(Record of Efficiency Test Date) 8.3 电压调整率计算 . 8(Line Voltage Calculation)8.4 负载调整率计算 . 8(Load Regulation Calculation)8.5 输出电流精度计算 . 9(Calculation of Output Curren
4、tAccuracy )8.6 绝缘电压和绝缘电阻测试 . 9(Insulation voltage and Insulation Resistance Test)8.7 波形记录 . 10(Waveform Recording)8.7.1 常温波形. 10(Waveform at Normal Temperature)8.7.2 高温波形. 10(Waveform at High Temperature)8.7.3 低温波形. 11(Waveform at Low Temperature)1 概述(Summary)1PCS EWP200C1050LED4P样机进行电性能测试 (Electron
5、ic Performance Test for Product 1PCS EWP200C1050LED4P) 2 测试地点、时间、人员(Test place, Time, Personnel)测试时间(Test time):2015-10-15测试地点(Test place):测试中心(Test Center)测试人员(Test personnel):黄秋霞(Qiuxia Huang)3 测试引用标准(Guide)3.1 技术指标要求(Technical Norm Requirement)产品设计规格书,DZ-CS3-003 A版 电源测试规,DZ-YF-004 A版 电子分公司LED驱动电源
6、验证评审检测标准(Product Design specification; ; )3.2 测试方法(Test Criterion)DZ-CS3-003 A版电源测试规()4 测试设备(Test Equipment)表4-1 测试仪器、设备设备名称(Equipment Type)型号(Model)生产厂家(Manufacturer)数字功率计(Digital power calculation)66202Chroma示波器(Oscilloscope)TDS3012C泰克(Teck)5 结论(Results) (Pass) (Fail)6 问题报告(Problem Report)序号(Numbe
7、r)问题描述(Problem Description)处理情况(deal with)123456 7 测试容和结果(Test Items and Results)7.1 常温环境电气性能测试(Electronic performance Test at Nomal Temperature)表7-1 常温工作测试结果 (Results of Test at Nomal Temperature ) 25测试容Test Items技术要求Technical Requirements测试条件Test Condition测试结果Test and Results结论Results输入特性Input Cha
8、racteristics输入电压围Input Voltage Range100277VAC按表8-1Acording Table 8-1见表8-1See Table 8-1通过Pass输入额定电压围Input Rated Voltage Range90305VAC按表8-1Acording Table 8-1见表8-1See Table 8-1通过Pass输入电流Input Current3A Max. (满载,110VAC)3A Max. (fully loaded, 110VAC)110V50Hz,Uo=200V2.15A通过Pass输入瞬态冲击电流(A)The Transient Imp
9、ulse Current Input70A Max.(满载,230VAC)70A Max.(230VAC Fully Loaded,)230V50Hz,Uo=200V冷态,90相位启动Cold Position, 90 Phase Starts68.0A通过PASS启动时间Starting Time 2s (满载)2s (Fully Loaded,)100V50Hz,Uo=200V246ms通过PASS输入功率因素Input Power Factor0.95 (满载,230VAC)0.95 (Fully Loaded,230VAC)230V50Hz,Uo=200V0.994通过pass空载功耗
10、no-load Power Consumption5W100/277V50Hz,空载100/277V50Hz, Fully Loaded1.392/0.825W通过PASS输出特性Output Characteristics空载电压(VDC)No-load Voltage (VDC)-100/277V50Hz,空载100/277V50Hz, Fully Loaded427.72/427.75V-输出电压(V)Output Voltage (V)180200VDC按表8-1According Table 8-1见表8-1See Table 8-1通过pass输出电流(mA)Output Curr
11、ent (mA)1.10A,90305VAC按表8-1According Table 8-1见表8-1See Table 8-1通过pass效率(%)Efficiency(%)90%(满载,230VAC)90%( Fully Load,230VAC)230V50Hz,Uo=200V见表8-2See Table 8-1通过Pass电压调整率Line Regulation -100277V50Hz,Uo=200V见表8-3See Table 8-1通过pass负载调整率Load Regulation2%-电流精度Current Accuracy 5% (230VAC)230V50Hz,Uo=180
12、200V见表8-5See Table 8-5通过pass保持时间Retention Time1s Max100V50Hz,Uo=200V80.4ms通过PASS纹波电流(mA)Ripple Current300mAp-p 100V50Hz,Uo=200V56.0mA通过安全与保护特性Security and Protection Features绝缘电压Isolation Voltage见表8-6See Table 8-6按表8-6According Table 8-6见表8-6See Table 8-6通过pass绝缘电阻Insulation Resistance见表8-6See Table
13、 8-6按表8-6According Table 8-6见表8-6See Table 8-6通过PASS输出短路保护Output Short Circuit Protection保护,自动恢复Protection, Self-recovery-过载保护Overload Protection 110-150%保护,自动恢复110-150% Protection, Self-recovery-7.2 高温环境电气性能测试(Electronic performance Test at High Temperature)试验样机带满载并置于恒温恒湿箱中,箱温度设45,湿度设为95%RH,稳定工作4h
14、后进行电性能测试及开关机测试。Put experimental prototype with full load in constant temperature and humidity chamber, at the temperature of 45 and humidity of 95%RH, Starting Electronic Performance Test and Power ON-OFF Test after it has worked for 4hours steadily.表7-2 高温工作测试结果(Results of the Test at High Temperat
15、ure ) 45测试容Test Terms技术要求Technical Requirements 测试条件Test Condition 测试结果Test Results结论Results输入特性输入电压围Input Voltage Range100277VAC按表8-1According Table 8-1见表8-1See Table 8-1通过pass输入额定电压围Input Rated Voltage Range90305VAC按表8-1According Table 8-1见表8-1See Table 8-1通过pass输入电流Input Current 3A Max. (满载,110VA
16、C)3A Max. (Fully Load,110VAC)110V50Hz,Uo=200V2.14通过pass输入瞬态冲击电流(A)The Transient Impulse Current Input (A)70A Max.(满载,230VAC)70A Max.( Fully Load,230VAC)230V50Hz,Uo=200V冷态,90相位启动Cold Position, 90Phase Starts56.4A通过pass启动时间Starting Time 2s (满载)2s (Fully Load,)100V50Hz,Uo=200V244ms通过pass输入功率因素Iuput Pow
17、er Factor0.95 (满载,230VAC)0.95 (Fully Load,230VAC)230V50Hz,Uo=200V0.994通过Pass空载功耗no-load Power Consumption5W100/277V50Hz,空载100/277V50Hz,Fully Load 0.880/0.846W通过pass输出特性空载电压(VDC)No-load Voltage (VDC)-100/277V50Hz,空载100/277V50Hz, Fully Load428.42/428.53V通过pass输出电压(V)Input Voltage 180200VDC按表8-1Accordi
18、ng Table 8-1见表8-1See Table 8-1通过pass输出电流(mA)Output Current (mA)1.10A,90305VAC按表8-1According Table 8-1见表8-1See Table 8-1通过pass效率(%)Efficiency (%)90%(满载,230VAC)90%(Fully Load,230VAC)230V50Hz,Uo=200V见表8-2See Table 8-2通过pass电压调整率Line Regulation-100277V50Hz,Uo=200V见表8-3See Table 8-3通过pass负载调整率Load Regula
19、tion2%-电流精度Current Accuracy 5% (230VAC)230V50Hz,Uo=180200V见表8-5See Table 8-5通过pass保持时间Retention Time1s Max100V50Hz,Uo=200V97.6ms通过pass纹波电流(mA)Ripple Current(mA)300mAp-p 100V50Hz,Uo=200V56.0mA通过pass安全与保护特性绝缘电压Isolation Voltage见表8-6See Table 8-6按表8-6According Table 8-6见表8-6See Table 8-6通过pass绝缘电阻Insulation Resistance见表8-6See Table 8-6按表8-6According Table 8-6见表8-6See Table 8-6通过pass输出短路保护Output Short Circuit Protection保护,自动恢复Protection, Self-recovery -过载保护Over-load Protection 110-150%保护,自动恢复110-150% Protection, Self-recovery-7.3