1、英文控制台说明书IntroductionDear Customer,Thank you for purchasing our products. If youre the first time using this product, please read the instruction, will help you skilled use of the instrument.Our aim is to constantly improve the companys products, so the product you use might be has a little differenc
2、e from operation instruction. If there are changes to be made, we will use the attached way to inform you, please understanding! You have not clear place, please contact with the company the after-sale service, we will meet your requirements.Due to the input/output terminal, test column are possible
3、 with voltage, when you plug test line, power supply socket, will produce the spark, be careful to avoid electric shock, shock hazard, pay attention to safety!DisclaimerThis manual according to the existing information production, its contents are subject to change without prior notice. The company
4、in writing the handbook of time already do our best to ensure the accuracy and reliability of the content, but the company do not take the responsibility of this manual wrong omission, inaccurate or false cause loss and damage to assume responsibility.ReadersThis manual readers object for this test
5、instrument test technical personnel, as well as the configuration and the instrument of the test panel of administrator.Content introductionThis manual introduces in detail the installation of the product, measurement, use, maintenance, etc.GuaranteeOur companys produces, in delivery within one mont
6、h of the date, such as product appear defect, a replacement. One year if the product appears defects, a free maintenance. More than one year if the product appear defects, shall be paid for the lifelong maintenance.Safety requirementsPlease read the following safety matters needing attention, in ord
7、er to avoid personal injury, and to prevent the product or connected with any other products damaged. In order to avoid the possibility of danger, this product can only be within the prescribed scope of use.Only qualified technical personnel to implement maintenance.To prevent fire or personal injur
8、y:Use appropriate power cord. Can only use this product special, and accord with the product specifications of the power cord.Connected correctly and disconnect. When the test wire and charged terminal connection, please do not optional connect or disconnect test conductor.Product ground. This produ
9、ct in addition to through the power line earthed conductor earthed outside, product shell grounding column must be grounded. In order to prevent electric shock, the grounding conductor must be connected with the ground. With this product input or output terminal connection before, should ensure that
10、 the product has the correct ground.Notice that all terminal rating. In order to prevent fire or shock hazard, please note that this product all rating and mark. Before connection please read the product specification, in order to further understand the rating information.Please do not operations in
11、 an instrument cover. Such as cover or panel has been discharged, do not operate this product.Use appropriate fuse. Only can use with this product regulation type and rating of the fuse.Avoid contact with bare circuit and charged metal. Products are electric; do not touch bare contact and parts.In a
12、 suspicious failure, do not operate. If suspect the products are damaged, please the company maintenance personnel for inspection, do not continue to operate.Please do not in wet environment operation.Please do not in explosive environment operation.Keep product surface cleaning and drying.Notice Sh
13、ould there be any inconsistencies between Chinese and English versions, the Chinese version shall prevail. The English version is for reference only. The manufacturer reserves the final interpretation right.Contents. Product Introduction 1. Features 1. Panel schematic diagram 2. Main technical param
14、eters 3. Operating instructions 3. Operating instructions 5. Print instructions 8. Introductions 9. Service conditions 10. Brief trouble shooting 10XI. Notice 10XII. Maintenance 11XIII. Transportation and storage 11XIV. Unpacking and inspection 12XV.Other 12. Product Introduction It is the latest in
15、dustry according to the national standard of testing and design of the test equipment, the safe and reliable, powerful, easy to use, simple maintenance, mainly used for all kinds of electrical appliances, electrical components, insulation materials by voltage of the dielectric strength test, evaluat
16、ion of product insulation level, found that the test object insulation defects, measure overvoltage ability, is the electric power operation related departments, electrician electrical appliance manufacturing enterprise, metallurgy, coal mine, electrification railway related departments, scientific
17、research units and institutions of higher learning should withstand voltage test equipment preferred products. Features Voltage, current, time, state information and prompt information data 4.7 feet daimio liquid crystal display, clear reading and directly; All Chinese interfaces, the operation is s
18、imple and clear, can adapt to a variety of applications; Light touching the key operation, all functions are controlled through the key setting, improved the security and reliability of products; Full digital calibration mode, abandoned old potentiometer adjustment, field use is very convenient, eas
19、y to control the accuracy (this function with password protection); Key directly set test transformer (this function with password protection), the connection of different voltage levels of tester, application freely and truly a console with many sets of transformer matched use; State remind functio
20、n, all Chinese conductive operation, even in the absence of instructions cases can be well-trained operation; Test process, the screen on the twinkling high pressure symbol display, constantly remind operators pay attention to safety; Test results show that function, can automatic judgment test resu
21、lts (test through or test failure), and reliable record test product over current, flashover or breakdown of voltage; Test results voice alarm function, test through or test failure, the equipment will produce different alarm sounds, test personnel can directly by the alarm sound identification test
22、 results; Stop function, automatic control, this function can be realized at any point to step up or step down suspension, and pause time by test personnel mastering, convenient observation test product state; Automatic timer function. Automatic control, when automatic voltage rise to set value, aut
23、omatic equipment at the beginning of time, when the time to time, showing test results, the equipment to be automatic back to zero; Manual timing function, manual control, the timer can be manual start, when the pressure time, equipment, automatic back to zero (only desktop devices have this functio
24、n); Manual control mode, the model similar to the traditional electric liters/dropping way, increase/decrease the button control, equipment, automatic judgment/lower limit position, overvoltage protection; Booster speed intelligent control, when the voltage to achieve target voltage 80%, booster spe
25、ed will be slow down, when achieve voltage 90%, booster speed slow further; The hardware and software anti-interference technologies, stable performance, strong anti-jamming. Panel schematic diagramFigure 3-1 panel schematic diagram(Tiny chromatic aberration, takes material object as the standard).
26、Main technical parameters1. Rated capacity (General Parameters)1kVA、2kVA、3kVA、5kVA、10kVA、15kVA、20kVA、30kVA、50kVA、100kVA、150kVA、200kVA、300kVA、500kVA2. The following is 5 kVA technology parameters Low voltage current: 22.7ALow voltage: 0 220VHigh-voltage current: 0 1000mAHigh voltage: 0 50kV Voltage m
27、easurement accuracy: 1.0 FS 3d Current measurement accuracy: 1.0FS 3 d Time length: 0 999 S(Special model can be used to work long hours) Supply voltage: AC220V 10%, 60Hz1 Hz Environmental conditions: ambient temperature 050 RH 85 RH . Operating instructions Figure 5-1 key Booster button, manual con
28、trol mode, press , high voltage will continue to step up, loosen the stop booster, if already to upper limit will no longer booster.Decompression button, manual control mode, press , high voltage will continue to decompression, loosen the stop dropping, if already to lower limit will no longer decom
29、pression. Pause button, when press this button, the voltage regulator will stop booster and decompression. This function is particularly suitable for automatic control mode, when the voltage in the automatic rise, push down this button, the equipment will be suspended booster, again according to the
30、 button, the voltage will continue to rise to a set voltage. Users can use this button to agile, let the automatic control process become more perfect.Manual timing button, when work in manual mode, press this button, can activate pressure time.Figure 5-2 operation key panelReset key: used for progr
31、am reset.Function key: can confirm change setting; Can sequential transformation parameters set items.Shift key: change in setting for mobile is set a; Used for switching voltage value of the ac, dc display mode (in measuring state).Reduce the key: change set, used to reduce was set to a value; Used
32、 to switch display the measurement process of voltage and current peak (in measuring state).Increase the key: change set, used to increase was set to a value; Used for peak keep function whether start (in measuring state). Operating instructions1. ThebootscreenOpentheequipmentpowerswitch,theequipmentintothebootscreen,inthebootscreen,itwillshowmanufacturersinformation. Theboot