1、常用建筑材料热物理性能计算参数附件1常用建筑材料热物理性能计算参数取值分类材料名称干密度P(kg/m3)计算参数导热系数入W/(m K)蓄热系数S (周 期 24h)2W/(m K)比热容CkJ/(kg K)混凝土钢筋混凝土25001.7417.200.92碎石、卵石混凝土23001.5115.360.9221001.2813.570.92沥青混凝土21001.0516.391.68烧结陶粒混凝土135114500.496.430.84145115500.577.190.84155116500.668.010.84165117500.768.810.84175118500.879.740.84
2、185119501.0110.700.84全轻混凝土5516506517507518508519509511050105111501151125012511350泡沫混凝土3004005006007008009001000砂水泥砂浆18000.162.701.050.183.091.050.203.481.050.233.961.050.264.441.050.284.831.050.315.311.050.365.961.050.081.421.050.101.811.050.122.201.050.142.591.050.183.161.050.213.641.050.244.121.05
3、0.274.591.050.9311.371.05浆混合砂浆17000.8710.751.05无机保温砂浆 3300.071.261.05 4000.0851.611.05 5000.101.951.05 6000.122.341.05胶粉聚苯颗粒保温浆 料1802500.060.95砌 块 及 砌 体普通烧结页岩空心砖砌体8000.541.05蒸压加气混凝土砌块4265250.142.361.055266250.162.751.056267250.183.151.057268250.203.541.05烧结页岩多孔砖砌体14000.587.851.05节能型烧结页岩空心 砌块(孔排数9排,
4、孔洞率50%砌体 45%砌体8019000.304.531.05无机复合烧结页岩空心砖(规格:长200mm 宽 190mm 厚 115mm填充厚度为40mm密度等级为B03级及以 下的泡沫混凝土)砌体 3排)8019000.284.37建 筑 板 材防水珍珠岩板1502000.061.061.32胶合板6000.174.57软木板3000.0931.952.511500.0581.091.89纤维板10000.348.131.896000.235.282.51石膏板10500.335.281.05纸面石膏板11000.314.731.16纤维石膏板11500.305.201.23水泥刨花板10
5、000.347.272.017000.194.562.01木屑板2000.0651.542.10硬质PVC板14000.160铝塑复合板13800.450轻质硅酸钙板5000.116纤维增强硅酸钙板 14000.35岩棉板平行纤维 1400.0400.701.22垂直纤维 1000.0480.751.22硅酸铝棉板2503000.0450.70复合酚醛泡沫板 600.040二氧化硅微粉真空隔热保温板3504500.0080.45建 筑 板 材难燃型膨胀聚苯板18220.0410.271.3825 350.32难燃型挤塑聚苯板25 350.0300.271.38复合硬泡聚氨酯板 350.0240
6、.291.38 450.29泡沫玻璃板 1600.052无 机 纤 维 材 料岩棉、矿渣棉 1500.044玻璃棉板、毡400.0370.521.06膨 胀 珍 珠 xJU岩 制 品水泥膨胀珍珠岩4000.162.491.176000.213.441.178000.264.371.17沥青、乳化沥青膨胀珍珠岩3000.0931.771.554000.122.281.55木材橡木、枫树热流方向垂直木纹7000.174.902.51热流方向顺木纹7000.356.932.51松、木、云杉热流方向垂直木纹5000.143.852.51热流方向顺木纹5000.295.552.51其/、他材夯实粘土20
7、001.1612.991.0118000.9311.031.01料加草粘土16000.769.371.0114000.587.691.01轻质粘土12000.476.361.01花岗石、玄武岩28003.4925.490.92大理石28002.9123.270.92砾石、石灰岩、砂岩24002.0418.030.92SBS改性沥青防水卷材9000.239.371.62APP改性沥青防水卷材10500.239.371.62合成高分子防水卷材5800.156.071.14油毡纸6000.173.331.47石油沥青14000.276.731.6810500.174.711.68紫铜85004073
8、240.42青铜800064.01180.38建筑钢材785058.21260.48铝27002031910.92铸铁725049.91120.48玻璃钢18000.529.251.26建筑隔墙用轻质条板面密度传热系数(板厚120mrh2(kg/m ) 110(W/旷K) 2.0膨胀聚苯板(EPS板) 0.0380.041挤塑聚苯板(XPS板)0.0280.03 岩棉板0.0410.045胶粉聚苯颗粒保温浆料0.0570.06聚氨酯发泡材料0.0250.028珍珠岩等浆料0.070.09附件3常用建筑材料热物理性能计算参数取值全国民用建筑工程设计技术措施/暖通空调动力 (2009年版)附件4常
9、用建筑材料导热系数的修正系数取值序号材料名称使用范围修正系数1难燃型膨胀聚苯板用于外墙、架空楼板1.20用于屋面1.252复合硬泡聚氨酯板用于外墙、架空楼板1.10用于屋面1.153蒸压加气混凝土砌块用于墙体1.25用于屋面1.504无机保温砂浆用于外墙、分户楼板1.305复合酚醛泡沫板用于外墙、架空楼板1.156难燃型挤塑聚苯板用于外墙、架空楼板1.15用于屋面1.207现浇泡沫混凝土用于分户楼板1.20用于屋面1.508胶粉聚苯颗粒保温浆料用于外墙1.309烧结陶粒混凝土用于屋面1.5010全轻混凝土用于分户楼板、地面1.2011二氧化硅微粉真空隔热保温板用于外墙、架空楼地面1.40用于屋
10、面1.6012硅酸铝棉板用于外墙1.30用于屋面1.5013岩棉板用于外墙1.3014泡沫玻璃板用于外墙1.20实例1华铜搬迁小区住宅建筑围护结构热工性能判定表3.1-2 建筑物屋面传热系数每层材料名称厚度mm导热系数w/(m.k)修正系数热阻值m.k/w砂浆找平层200.9310.022SBS高聚物改性沥青防水卷材30.2310.013水泥砂浆找平层200.9310.022EPS保温板1000.0411.22.927钢筋混凝土1201.7310.069水泥砂浆找平层200.9310.022屋面各层之和3.074屋面热阻R)=R+X R+R=3.232屋面传热系数K=1/Ro=0.309表3.1-3 建筑物外墙主断面传热系数每层材料名称厚度mm导热系数w/(m.k)修正系数热阻值m.k/w聚合物水泥砂浆50.9310.005硬泡聚氨酯喷涂400.0251.11.760EPS胶粉聚苯颗粒浆料150.061.250.313水泥砂浆200.9310.022轻集料混凝土小型空心砌块2400.5310.453水泥砂浆200.9310.022外墙各层之和
copyright@ 2008-2022 冰豆网网站版权所有
经营许可证编号:鄂ICP备2022015515号-1