1、+301015覆冰厚度b=5mmLGJ-185/45型导线在各种情况下的比载如下表1-2所示。 表1-2 LGJ-185/45型导线比载表 10-3N/(mmm2)g136.510g4(15)13.050g5(15,10)16.012g6(35)61.698g2(5)14.969g4(18)18.792g5(15,15)36.028g7(5,10)52.359g2(10)36.024g4(21)21.742g5(20,10)19.241g7(5,15)55.789g2(15)63.164g4(25)30.813g5(20,15)43.291g7(10,10)73.652g2(20)96.389
2、g4(30)39.151g6(10)36.968g7(10,15)78.029g3(5)51.479g4(35)49.736g6(15)38.772g7(15,10)100.952g3(10)72.534g5(5,10)9.566g6(18)41.062g7(15,15)105.985g3(15)99.674g5(5,15)21.500g6(21)42.493g7(20,10)134.284g3(20)132.899g5(10,10)12.784g6(25)47.775g7(20,15)139.772g4(10)5.800g5(10,15)28.764g6(30)53.5332.各气象条件时的
3、比载确定根据表1-1以及表1-2可列出第二气象区的各种气象条件参数及比载表,如下表2-1所示。表2-1 第二气象区的各种气象条件参数及比载编号气象条件气温()覆冰(mm)比载N/(mmm2)1最低气温36.51010-32平均气温33053.5334最大覆冰552.359最高气温406安 装36.9687事 故8938.7723.安全系数及防振措施的确定本设计的导线强度安全系数K=2.5,防振锤防振。4.临界档距计算及辨别4.1计算数据由架空输配电线路设计可查的LGJ185/45型导线的导线截面积A=227.83 mm2,热膨胀系数=17.810-6(1/),弹性系数E=80000MPa,计算
4、拉断力TP=80190N,导线最大使用应力,年平均运行应力,其他数据列于表4-1中。表4-1 计算数据表控制应力(MPa)g/(1/m)140.792.59310-4A3.719B3.802C年平均气温87.994.149D4.2临界档距计算 计算式为 4.3有效临界档距辨别有效临界档距辨别见表4-2,判别结果见图4-1 表4-2 有效临界档距判别表Lcr.AB=173.38Lcr.BC=1010.81Lcr.CD=虚数Lcr.AC=332.48Lcr.BD=虚数Lcr.AD=虚数 (m)图4-1 判别结果图4.4结论从表4-2中可以看出,A,B,C中都有虚数,故控制气象条件为D控制,即控制气
5、象条件为年平均气温,控制应力为。5.机械特性应力特计算以有效临界档距辨别结果为已知条件,逐一求出其他各种气象条件下各种代表档距值时的应力和弧垂值。以最低气温为例,计算出应力特性,计算结果列入表5-1。 其中 ,表5-1 应力特性计算表控制条件abcd(MPa)年平均气温gm=36,51010-3N/(mm=87.99MPa tm=15502500122.155 11108.168 8.258 0.203 122.891 0.093 10010000117.851 44432.670 16.816 0.428 120.891 0.378 15022500110.677 99973.508 26.
6、028 0.706 117.873 0.871 20040000100.634 177730.680 36.395 1.085 114.250 1.598 2506250087.721 277704.188 48.727 1.666 110.475 2.582 3009000071.939 399894.030 64.569 2.693 106.920 3.842 35012250053.287 544300.208 87.526 4.928 103.803 5.386 40016000031.766 710922.720 129.557 12.235 101.193 7.216 450202
7、5007.375 899761.568 302.484 123.038 99.063 9.329 500250000-19.885 1110816.750 19.885 204.687 30.881 97.343 11.721 其余各天气情况应力特性列入表5-2,表5-3中。表5-2 应力特性计算表控制气象档距g1=36。510t=15g1=53.533t=10g7=52.359t=-5g1=36.510t=40fmm2)m=87.99MPa tm=1587.990 0.130 96.253 0.119 116.712 0.098 54.672 0.209 0.519 99.098 0.461
8、 117.365 0.389 59.291 0.770 1.167 102.611 1.001 118.259 0.868 63.935 1.606 2.075 106.098 1.721 119.228 1.531 67.939 2.687 3.242 109.257 2.611 120.159 2.374 71.240 4.004 4.668 111.998 3.667 120.996 3.395 73.921 5.556 6.354 114.330 4.890 121.722 4.593 76.093 7.347 8.299 116.296 6.279 122.338 5.969 77.
9、854 9.379 10.503 117.947 7.835 122.856 7.522 79.290 11.655 12.967 119.334 9.561 123.290 9.254 80.468 14.179 表5-3 应力特性计算表g1=36.968t=0g7=36.968g1=38.772108.876 0.105 108.853 88.025 88.167 0.129 107.549 0.424 107.459 0.425 88.118 0.550 88.630 0.515 105.624 0.972 105.431 0.974 88.241 1.164 89.236 1.151
10、103.428 1.765 103.111 1.770 88.368 2.066 89.858 2.032 101.253 2.817 100.808 2.829 88.485 3.224 90.424 3.154 99.288 4.137 98.727 4.160 88.585 4.637 90.908 4.518 97.614 5.727 96.953 5.766 88.668 6.305 91.310 6.123 96.232 7.588 95.491 7.647 88.735 8.229 91.639 7.968 95.111 9.717 94.306 9.800 88.789 10.
11、408 91.906 10.055 94.205 12.111 93.349 12.222 88.833 12.844 92.124 12.385 6.绘制机械特性曲线 上面已经将各种气象条件时的应力特性计算出来,接下来我们就可以以代表档距为横坐标,应力或弧垂为纵坐标,绘制各种气象条件时的应力曲线弧垂曲线。导线机械特性曲线图见下图图6-1所示。图6-1 导线机械特性曲线致 谢本次课程设计是在李建军老师和刘润泽老师的亲切关怀和悉心指导下完成的,感谢老师在这为期一周的课程设计中对我们的关怀和悉心指导,为我们在设计过程当中提出了很多宝贵的意见和建议,并为我们解决了很多疑难的问题,使我们在学习中又进一
12、步懂得了许多以前未曾解开的谜团,这次课程设计的最终成功归功于辛勤为我们提供大力帮助的两位老师,在此我们对两位老师表示衷心的感谢。在本次课程设计即将结束之际,我的心情万分激动,从课程的选题、资料的收集到论文的撰写编排整个过程中,我得到了许多的热情帮助。我首先要感谢李建军及刘润泽两位指导老师,是你们的诸多宝贵意见才能使我们的这次课程设计顺利的完成,也使我们有了更好的学习气氛。在本次设计过程中,本专业的其他同学也经常为我们提出一些意见和建议,在此表示诚挚的感谢。在做此设计时,次课程设计中的个别段落的内容参考了一些已出版的文献,这些文献已在本课程设计最后的参考文献中一一列出,在此我想对这些文献的作者表示忠心的感谢。参考文献1 熊先仁,郑和东,张小峰.架空输配电线路设计M.北京:中国电力出版社.2011.5.2 柴玉华,王艳君.架空线路设计M.北京:中国水利水电出版社.2007.23 孟遂民,孔伟.架空输电线路设计M.北京:中国电力出版社,2007.4 王艳君,黄丽华,王爱茹.架空送电线路导线机械计算的计算机实现J. 河北农业大学学报,2000.2.5 张子引,徐红男.送电线路弧垂及悬垂线夹安装位置调整M.山西电力,2004.3
copyright@ 2008-2022 冰豆网网站版权所有