1、5PIN Code Activated Features and Car Call PIN Code Locking (PCL) Setup304UI Range 0 to 990=Setup of PCL and PIN codes accepted1=Define floors of locked group 12=Define floors of locked group 2.63=Define floors of locked group 63-UI Range 100s1-00=Reset (clear) all locked groups1-01=Reset (clear) loc
2、ked group 11-02=Reset (clear) locked group 21-63=Reset (clear) locked group 63UI Range 2002-00=Set PIN code for Master group2-01=Set PIN code for group 12-02=Set PIN code for group 22-63=Set PIN code for group 63UI Range 300Set PIN code for PIN activated features:3-01=PRC3-02=OSS3-03=OCL3-04=OCVDefi
3、ne the floors that are members of each PIN code locked group.Clear the floors that were set via 1-5-1 to 1-5-63. Individual groups can be cleared, or all groups can be cleared at one time.Program the PIN code for the locked groups that can be deactivated via a PIN code entry on the COP. Only availab
4、le if menu item 1-4 = 1.Program the PIN code for the features that can be activated/deactivated via a PIN code entry on the COP. Only available if menu item 1-4 = 1.Notes:1) Elevator must be in RDF (machine room inspection) when this is changed.锁定取消子菜单1=由PRC取消子菜单2=由PRL H/HEL取消子菜单3=由PRL L取消子菜单4=由ATS取
5、消submenu 5 = lockings overridden by Destination Calls from PC-group or Car Calls from E-linksubmenu 6 = lockings overridden by DELI定义选哪个开关取消锁定输入安全码时间859秒从输入第一个按钮到安全代码输入完的时间(全能访问)访问控制0=关闭1=全能访问(IAC)2=高级安全界面(HLI)允许或不允许访问控制9关闭重新开门0=有效 (在被锁层楼,开门按钮不起作用)1=有效 (在LOC时)2=有效(在LOC时即使曾经开过)允许或不允许门重开门10开门时间60160秒,
6、每步一秒内呼或外呼时, 门保持开启的时间11重新开门时间2025025秒,每步秒按开门按钮时,门保持开启的时间12选择ADO,ACL和修正运行0=no ADO, ACL, COD,1=ADO, ACL, COD, 2=no ADO, no ACL, no COD, 3= ADO, no ACL, no COD, 4= ADO, no ACL, COD, 5=ADO, ACL, no COD, 6=no ADO, ACL, no COD, 7=no ADO, no ACL, CODADO=提前开门. 当LCEADO板用于再平层开门(ACL B)时, 此参数可以用于取消ADO.13使用强迫关门0=
7、OFF, 1=ON, 2=NUD L, 3=NUD AU,4=NUD NA如果门被阻止关闭超过强迫关门时间限制, COP上的峰鸣器响, 门已很慢的速度关闭. 这个功能使关门按钮, 光眼和光幕失效. 如果选择AUD L且载荷60%时, 强迫关门时间为5秒.14强迫关门限制1059秒,每秒一步激活强迫关门的时间限制15新内呼快速关门990=没有使用, 秒, 每步秒当门正在开启或已打开时, 当有新内呼包括当前轿厢所在楼层内呼时, 保持开门时间将被缩短. 例如由10秒减小到1秒.16光幕延时秒,每步秒在光束遮挡后,保证维持门保持开启时间17光幕快速关门0=关闭,1=开启光束被挡时, 允许将开门时间到缩
8、短光幕延时时间(1-16).18禁止同时开门1=A门优先,2=B门优先,3=同时开门TTC CTF功能, 仅用于有内呼锁定功能时.19Extended door reopen time301201120秒,每步1秒Time elevator doors are kept open with DOE. Applicable only for DOE B.门蜂鸣器0=关闭,1=开启,2=CGM,3=DOIGOH IT功能用于残疾人. 当门到达开门限制时, COP上的蜂鸣器响, 通知盲人可以进出轿厢.21重开门时间延长0=按钮(DOE B),1=开关和蜂鸣器(DOE SI),2=开关没有蜂鸣器(DO
9、E S),3=DOE T船用开关DOE=重开门时间延长,信号输入在LCECOB板上XC17(34:E).22DOP 类型0=没有,1=DOP CS选择DOP类型23A门类型0=没有,1=AMD,2=持续力矩,3=定时控制,4=拉门+AMD, 5=拉门+持续力矩, 6=拉门+定时控制, 7=拉门, 8 = swing + car Besam, 9 = swing + automatic car Besam, 14 = Freight doors (Peelle or Courion)选择前门类型24B门类型选择后门类型250 .9,9秒,每步 秒当门的类型为定时控制,全速开门的时间26关门时间当
10、门的类型为定时控制,全速关门的时间27Door contact filtering time0秒,每步秒Door contact filtering time to avoid contact bouncing problems.29轿门解锁刀控制0=2组平层开关+层门触点, 1=3组平层开关+层门触点, 2=2组平层开+轿门触点,3=3组平层开+轿门触点,4=2组平层开+轿门触点,5=3组平层开+轿门触点0=解锁刀在30+61:U或61:N时释放,在层门触点闭合时锁住,1=解锁刀在30+61:U和61:N时释放,在层门触点闭合时锁住, 2=解锁刀在30+61:N时释放,在轿门触点闭合时锁住,
11、 3=解锁刀在30+61:N时释放,在轿门触点闭合时锁住泊梯泊梯楼层0 或者是从底层到顶层的任意楼层数如果选择群组泊梯(菜单1-33),这个值为1号梯的基本泊梯楼层(PAM),为2号梯的第二泊梯楼层(PAS),如果2号梯与3号梯不需要(PAS)时,这个值必须为0.31泊梯时开门0=关闭, 1=A门优先, 2=B门优先, 3=两个门同时开泊梯时门的功能32泊梯延时1.99秒, 每步一秒泊梯前的电梯空闲时间33泊梯模式0=关闭, 1=单台电梯, 2=群组泊梯1=本台电梯PAD功能,电梯一直泊梯在泊梯楼层(菜单1-30). 2=本台电梯为群组泊梯(PAM和PAS), 泊梯楼层用于群组.34自动从指定
12、楼层派梯0表示不用, 否则是从底层到顶层的任意楼层数ADF= 自动从指定楼层派梯, 轿厢空闲时从该楼层派遣.35自动派遣返回楼层0=派遣到主楼层, 否则是从底楼到顶楼的任意楼层数.ADF将电梯调到本楼层.36ARH 功能2540=没有ARH, 否则为ARH时间且以分钟计算在设定的时间后, 转为液压驱动.37泊梯区域0=OFF,1=ON允许或不允许泊梯区域功能,也可选择133=238泊梯区域下楼层数0=没用,否则是指定泊梯区域下楼层数选择泊梯区域下楼层数,137=1时有效39泊梯区域上楼层数0=没用,否则是指定泊梯区域上楼层数选择泊梯区域上楼层数,137=1时有效呼梯40反向内呼电梯能接受与运行
13、方向相反的内呼.41取消错误内呼子菜单1;0,1,2,3,40=关闭,1=FCC C,2=FCC L,3=FCC B,4=FCC D,子菜单2:0,10=关闭,1=FCC RFCC C=两次停梯时,没有人进出轿厢(光幕没遮挡), 取消所有剩余内呼.FCC L=基于称重小于5又有多个内选时取消登记内选FCC B=根据称重或光幕遮挡情况取消登记FCC D=虚假内选的取消FCC R=取消有效登记42内呼登记蜂鸣当登记内呼时, COP上的蜂鸣器发出短促蜂鸣声.43允许越过外呼0=不用, 1=使用超时的外呼2=use Timed Out Call ( no priority for FET/FEB ca
14、lls)在某种特殊的情况下,电梯越过等候时间较短的外呼, 而去响应等候时间长的外呼. 以提高了电梯运送能力.44司机服务0=没有ATS, 1=正常ATS,2=ATS HK, 4=ATS C, 5=ATS NA定义司机服务时, COP是怎样操作的.45锁梯类型0=不锁, 1=轿厢内呼锁定(LOC E), 2=外呼锁定(LOL E), 3=内呼和外呼都锁定.定义LCEOPT板上锁梯输入的用途.46下呼优先子菜单1: 下呼优先第一选择楼层 下呼优先第二选择楼层子菜单3: 下呼优先第三选择楼层PRA=厅外优先外呼, 最多定义3个优先下呼楼层0=没有楼层选择47上呼优先 上呼优先第一选择楼层 上呼优先第
15、二选择楼层 上呼优先第三选择楼层PRA=厅外优先外呼, 最多定义3个优先上呼楼层48呼梯信号取消点0=停梯时取消,1=减速点取消,2减速点取消内选定义呼梯信号取消点49错误外呼延迟时间外呼应答错失后转换到另一台电梯响应的延迟时间群组50群组中的梯号梯号两台群控时必须是1或2, 三台群控时必须为1,2,351E-link中的梯号64连接到E-link中的电梯必须有不同的节点号.52Konexion中的梯号0=Konexion没有激活, 1.8=梯号连接到Konexion中的电梯必须有不同的Konexion梯号.53重开门类型0=no reopening ,1=开门1次, 2=开门数次, 3=RE
16、O HK当轿厢有内呼时, 一次外呼能开门几次54最低楼层楼层数. 改完最低楼层后, 必须重新做井道设定FEB选项,仅用于电梯群组中,一台或几台电梯的最低楼层不在同一层. 当修改最低楼层时, 电梯必须在底楼且在RDF模式下. 菜单1-30,34,35,59,64和89如果不是0,或比新设的最低楼层小, 则改为新设的最低楼层 55E-link中的群组号0,2,4,6.群组号选择E-link中的群组号56群控梯数群控大小一个群控里的成员58群控类型0=内含的群控界面,1=带群控电脑界面2 = MDE 2000 group interface3 = Embedded group interface w
17、ith immediate landing call allocation定义群控类型消防消防保留楼层0或是从底楼到顶楼的任意楼层消防保留楼层, FID B 和 FID M时必须为0.消防返回楼层消防探测(FID)和消防员电梯(FRD)第一阶段返回的楼层61地区代码0=不用,1=DE, 2=CS, 3=BE, 5=FR, 6=UK N, 7=NL, 8=UK S, 10=SE, 11=HK, 12=AU, 13=AE, 14=MY, 15=SG, 16=IN, 17=AP, 18=SA, 19=TW, 20=NZ, 21=L NZ,22=CA, 23=US, 24=EN81-72, 25=EN
18、81-72 Car sw, 26=KR1=德国, 2=俄罗斯, 3=比利时, 5=法国, 6=英国(normal), 7=荷兰, 8=英国(fireflighting),10=瑞典, 11=香港, 12=澳大利亚,13=阿联酋,14=马来西亚,15=新加坡, 16=印尼,17=亚太,18=沙特, 19=台湾, 20=新西兰, 21=新西兰(lockout)62类型0=不用, 1=FRD, 2=FID BC, 3=FID BO, 4=FID BC+FRD, 5=FID BO+FRD, 6=FID MC, 7=FID MO, 8=FID MC+FRD, 9=FID MO +FRD, 10=FID
19、AC, 11=FID AO, 12=FID AC+FRD, 13=FID AO +FRD定义是否有FID, FRD或FID+FRD功能.63消防探测时的开门侧1=A门+A门, 2=B门+A门, 3=A门+B门, 4=B门+B门消防探测(FID)和消防员电梯(FRD)第一阶段返回的消防楼层或第二返回楼层时,门的状况应急紧急驱动返回楼层0=附近可能的楼层, 否则从底楼到顶楼的任意楼层.EPD=紧急电源驱动选项, 定义EPD功能时的返回楼层. EPD可以通过LCEOPT(722:1)的X5/4输入来激活.65紧急驱动后门位置0=门关, 1=A门开, 2=B门开, 3=同时开定义紧急电源驱动返回后,门
20、的状况.66防火门0=不用FPD, 1=使用FPD*O, 2=FPD *TFPD=防火门, 防火门输入(通常关闭)输入在LCEOPT板722:8-722:B, 必须通过此参数激活.高峰67回基站梯数上高峰时回基站的梯数定义上高峰时回基站的梯数,基站由11设置68回第二基站梯数上高峰时回第二基站的梯数定义上高峰时回第二基站的梯数,基站由169设置69第二基站层楼数选择第二主基站其它70满载显示百分比80百分比数此参数可以调整满载限制. 不影响超载(110%)和称重设定. 当满载时, 电梯不响应外呼.71检修运行限制0=77N和77U停, 1=77U停, 2=77N停, 3=端站停,4=SED W
21、 + OTB AU A-side, 5=SED W + OTB AU B-side.可以通过减速开关(77U/77N)限制检修运行区间.检修运行最迟停在端站.72退出服务时的返回楼层开关在轿厢内: 0=最近楼层, 其它为指定楼层. 开关在层站:0=开关所在楼层, 其它为指定楼层.OSS=退出服务功能.73退出服务时门的状况OSS功能时门的状况.74优先外呼的类型0=没有PRL, 1=PRL LA, 2=PRL LO, 3=PRL HA, 4=PRL HO, 5=HEL AI, 6=HEL OI, 7=HEL CI, 8=HEL CI+PPRL LA, 9=HEL CI+PPRL LO, 10=
22、PRL HA + PRL LA, 11=PRL HA + PRL LO, 12=PRL HO + PRL LA, 13=PRL HO + PRL, 14=HEL CI + PRL LA (with HEL override of PRC),15=HEL CI + PRL LO,(with HEL override of PRC)定义电梯优先外呼的工作方式(连接到LCEFOB)75轿厢风扇节能059分钟关闭, 每步1分钟轿厢风扇延时时间. 当轿厢没有人使用时, 轿厢风扇会根据设定的时间关闭. 参考1-92(风扇类型).76轿厢照明节能轿厢照明延时时间. 当轿厢没有人使用时, 轿厢照明会根据设定的
23、时间关闭. 参考1-98参数.77轿厢照明电压监察0=关闭, 1=门开启,2=门关闭CLS选项. 假如LCECCB没有轿厢照明电压时,电梯会停止正常运行.78Konexion轿厢照明电流检测0=关闭, 1=开启轿厢照明电流检测器连接在轿厢Konexion盒中79特别的模式下的轿厢照明0=关闭, 1= ON in OSS & OFF in Inspection/RDF mode2=OFF in OSS & ON in Inspection/RDF mode3=ON in OSS & Inpspection/RDF mode在OSS模式下,可以关闭轿厢照明. 轿内锁梯钥匙可以用于锁梯和关闭照明.强制停靠主楼层0=不停, 1=下行, 2=上行, 3=两个方向,4=下行保安模式门操作,5=上行保安模式门操作,6=两个方向保安模式门操作CSM选项. 当经过主楼层时, 电梯正常停梯, 让保安检查轿厢内的乘客. 如果是贯通门, 两个门同时打开.81经过楼层时的信号0=关闭, 1=HAN C,2=HAN BHANC/B选项. 在COP上有一个可听见的蜂鸣器, 告诉乘客停站或经过该楼层.82RES E time059分钟To set the minimum time