1、1.5-30010-3002.5-300ZRAVLV224-30016-3003+1 44-1852 电缆外径及重量见表1013-1019 ZRC(A)VV ZRC(A)VLV芯数及截面mm导体直径 0.6/1kV 3.6/6kV电缆计算外径 电缆计算重量kg/kmCuAl1*1.51*2.51*41*61*101.381.762.232.733.547.27.68.59.09.87590115140190_10512514.93703101*16*1*251*351*501*704.456.07.08.310.010.712.613.615.317.025047064085015521525
2、533041615.817.318.319.621.345057069010853505506501*951*1201*1501*1851*24011.613.014.616.218.419.021.023.024.627.81115136016702040260052562074090022.924.926.528.130.4135516201935229528607658751005114513751*3001*4001*5001*6301*80020.623.826.630.034.034.237.641.245.6322542305240650081351365175521403180
3、32.836.339.342.847.23475448554806765845516102000235728503490*25mm2及以上采用圆形紧压导体表1014(0.6/1KV)ZRC(A)VV ZRC(A)VLV ZRC(A)VV22 ZRC(A)VLV32导体直径或扇形高度非铠装电缆钢带铠装电缆电缆计算重量mm 2*1.52*2.52*42*62*107.8*10.88.2*11.59.1*11.39.5*14.315.912014520039018526016.318.94355006603852*1617.753020.1835635*2*254.017.6685375990675
4、2*354.819.289046022.212307852*505.721.8122560524.816059752*706.824.21635.27.220651180*25mm2及以上采用扇形紧压导体.表1015(0.6/1kV) ZRC(A)VLV22芯数及截面mm2电缆计算外径kg/km Cu 3*1.53*2.53*43*63*1011.212.114.015.016.716520528035551516022032518.019.75907804304903*16*3*253*353*503*704.75.67.918.722.125.728.3715995135018152420
5、420880112021.723.225.128.932.310.1513151555224029107.1590513053*953*1203*1503*1853*2409.412.013.415.432.635.639.743.849.4323039584965608078151460175021702635334536.839.843.748.054.0381546255655687086952050239034203*30017.154.39680409058.9106505060*25mm2及以上采用扇形紧压导体。表1016(0.6/1kV) ZRC(A)VLV22导体直径或扇形高度
6、钢带铠装电缆 主地3*4+1*2.53*6+1*43*10+1*63*16+1*103*25+1*165.01. 7614.5645960119024029041054562522.725.2565945125015504755607058653*35+1*163*50+1*253*70+1*353*95+1*503*120+1*706.107.58.610.411.524.528.831.637.11505210028103810476074510151730209027.732.741.044.0192028304740578011651745266031103*150+1*703*185
7、+1*953*240+1*1203*300+1*15012.914.416.444.248.954.960.857257125911011290249530903890477048.352.959.365.26860841010510128403635437052906325表1017(0.6/1kV)4*44*64*104*16*4*255.315.118.220.423.444591530540052068018.119.321.226.45957109251260168558086010654*354*504*704*954*1206.38.910.611.825.930.133.739
8、.042.317152400321543005320845116014801940234029.137.943.246.321503145407052856360128019052330292533804*1504*18513.314.852.1660581152880352051.856.77790942040654825表1018(3.6/6kV)ZRCl(A)VV ZRC (A)VV22 ZRC(A)VLV22导体直径或扇形外径 非铠装电缆 钢带铠装电缆 Cu Al27.429.630.235.11040153519002430150033.634.439.120302290269032
9、8518202035235037.541.144.147.150.330853930569567951780216025052950335041.745.348.151.554.840154945565066808.25271034153885458054.658.8848510285470063.398501153553805945表1019(3.6/6kV) ZRC(A)VV42 ZRC(A)VLV4235.836.438.541.345.12650291540305220245027303100392040.040.842.745.5402042904855561066253720382
10、042504680532548.751.758.262.96250720583459650116354480497055506205716552.055.058.061.466.177008645993011280133755930641071357835890567.213695811070.4155459955*25mm2及以上采用紧压导体。性能特点1 电缆导体直流电阻及绝缘电阻符合表表标称截面+20 导体直流电阻km不大于电缆绝缘电阻 Mkm不小于0.6/1kv3.6/6kv+20 +70 1.512.30.01232.57.4110.30.010344.6110.20.0102101.
11、833.080.00721710.171161.151.915.90.00591470.147250.7271.205.40.00541210.121350.5240.8680.00471080.108500.3870.6414.60.0046950.095700.2630.4433.90.0039830.0830.1930.320740.0740.1530.2533.50.0035670.0671500.1240.206610.0610.09910.1643.20.0032560.0560.07540.1253.40.00340.0503000.06010.100450.0450.04700
12、.0778400.0400.03660.06033.00.0030360.0366300.02830.04962.70.0027330.0338000.02210.03670.0025290.0292 成品电缆在室温下,能承受交流50Hz电压试验,试验电压见表10111。单芯电缆浸入水中1h后按表10111规定进行电压试验。额定电压kV试验电压 kV时 间min0.6/1.053.6/6.011当用直流电压试验时,所加的电压为工频试验电压的2.4倍3 成品电缆能经受GB12666。590(等效于IEC3323标准)标准规定的成束电缆燃烧试验,其中ZRC型电缆应符合C类要求,ZRA型电缆应符合A
13、类试验要求。102乙丙橡皮绝缘阻燃电力电缆产品标准;QSL21495本产品适用于工频额定电压0.6/1kV及以下要求具有阻燃特性的线路中,供输配电能之用。型号、名称及使用条件见表 1021 表1021型号名 称使用条件ZRC-XEV乙丙橡皮绝缘聚氯乙烯护套阻燃电力电缆固定敷设于室内,电缆沟,托架敷射,电缆敷设时环境温度不低于0C,弯曲半径不小于电缆外径10倍ZRA-XEV乙丙橡皮绝缘聚氯乙烯护套高阻燃电力电缆ZRC-XEF乙丙橡皮绝缘氯丁橡皮护套阻燃电力电缆同上,电缆敷设时环境温度不低于20CZRA-XEF乙丙橡皮绝缘氯丁橡皮护套高阻燃电力电缆ZRC-XEYH乙丙橡皮绝缘氯磺化聚乙烯护套阻燃电力电缆同上ZRA-XEYHZRC型电缆用于要求通过GB12666.590(IEC3323)C类试验的一般阻燃线路。ZRA型电缆用于要求通过GB12666.590(IEC3323)A 类试验的
copyright@ 2008-2022 冰豆网网站版权所有