1、We will continue to improve the companys internal control system, and steady improvement in ability to manage and control, optimize business processes, to ensure smooth processes, responsibilities in place; to further strengthen internal controls, play a control post independent oversight role of ev
2、aluation complying with third-party responsibility; to actively make use of internal audit tools detect potential management, streamline, standardize related transactions, strengthening operations in accordance with law. Deepening the information management to ensure full communication zero resistan
3、ce. To constantly perfect ERP, and BFS+, and PI, and MIS, and SCM, information system based construction, full integration information system, achieved information resources shared; to expand Portal system application of breadth and depth, play information system on enterprise of Assistant role; to
4、perfect daily run maintenance operation of records, promote problem reasons analysis and system handover; to strengthening BFS+, and ERP, and SCM, technology application of training, improve employees application information system of capacity and level. Humanistic care to ensure zero. To strengthen
5、ing Humanities care, continues to foster company wind clear, and gas are, and heart Shun of culture atmosphere; strengthening love helped trapped, care difficult employees; carried out style activities, rich employees life; strengthening health and labour protection, organization career health medic
6、al, control career against; continues to implementation psychological warning prevention system, training employees health of character, and stable of mood and enterprising of attitude, created friendly fraternity of Humanities environment. To strengthen risk management, ensure that the business of
7、zero risk. To strengthened business plans management, will business business plans cover to all level, ensure the business can control in control; to close concern financial, and coal electric linkage, and energy-saving scheduling, national policy trends, strengthening track, active should; to imple
8、mentation State-owned assets method, further specification business financial management; to perfect risk tube control system, achieved risk recognition, and measure, and assessment, and report, and control feedback of closed ring management, improve risk prevention capacity. To further standardize
9、trading, and strive to achieve according to law, standardize and fair. Innovation of performance management, to ensure that potential employees zero fly. To strengthen performance management, process control, enhance employee evaluation and levels of effective communication to improve performance ma
10、nagement. To further quantify and refine employee standards . Work, full play party, and branch, and members in five type Enterprise construction in the of core role, and fighting fortress role and pioneer model role; to continues to strengthening four good leadership construction碳一联合装置电气安装工程检查及测试计划
11、电气工程项目检查与试验计划一、电力变压器的检查 1、变压器、电抗器到达现场后,应进行器身检查。器身检查要求: 1)周围空气温度不宜低于0,变压器器身温度不宜低于周围空气温度。 2)当空气相对湿度小于75%时,器身暴露在空气中的时间不得超过16H。 3)调压切换装置吊出检查、调整时,暴露在空气中的时间应符合下表的规定:环境温度()0000空气相对湿度(%)6565757585不控制持续时间不大于(h)2416108 4)器身检查时,场地四周应清洁和有防尘措施;不应在室外进行。 5)运输支撑和器身各部位无移动现象;所有螺栓应紧固,绝缘螺栓应无损坏;绕组绝缘层应完整,无缺损、变位现象;各绕组应排列整
12、齐,间隙均匀,油路无堵塞;绕组的压钉应紧固,防松螺母应锁紧。 6)绝缘围屏绑扎牢固,围屏上所有线圈引出处的封闭应良好;引出线绝缘包扎紧固,无缺损、折弯现象;2、电力变压器试验 1)电力变压器试验项目包括:测量绕组连同套管的直流电阻;检查所有分接头的变压比;检查变压器的三相结线组别和单相变压器引出线的极性;测量绕组连同套管的绝缘电阻、吸收比或极化指数;测量绕组连同套管的介质损耗角正切值tg;测量线圈连同套管直流泄漏电流;线圈连同套管交流耐压试验;测量与铁芯绝缘的紧固件及铁芯接地线引出套管对外壳的绝缘电阻;非纯瓷套管试验;绝缘油试验;有载调压切换装置的检查和试验;冲击合试验;相位检查;噪音的测量。
13、 2)试验标准:依据GB50303-2002建筑电气工程施工质量验收规范。 3)测试计划见附录:3. 变压器送电前的检查: 1)变压器试运行前应做全面检查,确认符合试运行条件时方可投入运行。 2)变压器试运行前,必须由质量监督部门检查合格。 3)变压器试运行前的检查内容: (1)各种交接试验单据齐全,数据符合要求。 (2)变压器应清理、擦拭净,顶盖上无残留杂物,本体及附件无缺损,不渗油。 (3)变压器一、二次引线相位正确,绝缘良好。 (4)接地线良好。 (5)通风设施安装完毕,工作正常;事故排油设施完好;消防设施齐备。 (6)油浸变压器油系统油门应打开,油门指示正确,油位正常。 (7)油浸式变
14、压器的电压切换装置及于式变压器的分接头位置放置正常电压挡位。 (8)保护装置整定值符合设计规定要求;操作及联动试验正常。 (9)于式变压器护栏安装完毕。各种标志挂好,门装锁。4、变压器送电试运行1)变压器第一次投入时,可全压冲击合闸,冲击合闸时一般由高压侧投入。2)变压器第一次受电后,持续时间不应少于10分种,无导常情况。3)变压器应进行35次全压冲击合闸,并无异常情况,励磁涌流不应引起保护装置误动作。4)油浸变压器带电后,检查油系统不应有渗油现象。5)变压器试运行要注意冲击电流、空载电流、一、二次电压、温度,并做好详细记录。6)变压器并列运行前,应核对好相位。7)变压器空载运行24小时,无异
15、常情况,方可投入负荷运行。二、电气电缆检查及测试计划 1、电缆绝缘电阻的测量:测试的数值见表额定电压(KV)13610绝缘电阻值(M)10200400 2、电缆直流耐压试验和直流泄漏试验:直流耐压试验和直流泄漏试验可同时进行,试验时,试验电压可分46段均匀升压,每阶段停留1min,并读取泄漏电流值。然后逐渐降低电压,断开电源。 3、电缆相位检查:电力电缆线路在敷设完毕与电力系统接通之前,必须按照电力系统上的相位标志进行核对检查,电缆线路的两端相位应一致并与电网相位相符合。 4、电缆线路的测试计划见附录;三、电气控制柜检查和测试计划 1、控制柜安装后在通电前应进行下列检查: 1)控制柜(盘)的固定及接地应可靠,柜、盘(屏)应漆层完好、清洁整齐。 2)柜、盘(屏)内所装电气元件应完好,安装位置应正确,固定牢固。 3)所有二次接线应正确,连接可靠,标志齐全、清晰。 4)柜内一次设备的安装质量验收要求应符合GB503032002的规定。 5)操动及联动试验运行正确,符合设计要求。 2、测试计划见附录:四、照明工程检查和测试计划 1、照明系统的测试和通电试运行应按下列程序进行: 1)电线绝缘电阻测试前电线的接续完成; 2)照明箱(盘)、灯具、开关、插座的绝缘电阻测试在就位前或接线前完成; 3)
copyright@ 2008-2022 冰豆网网站版权所有
经营许可证编号:鄂ICP备2022015515号-1