1、Power supplies monitor MARGINALTemperatures monitor HEALTHYFans monitor HEALTHYWWN servers monitor HEALTHYStandby CP monitor HEALTHYBlades monitor HEALTHYFlash monitor HEALTHYMarginal ports monitor HEALTHYFaulty ports monitor HEALTHYMissing SFPs monitor HEALTHYAll ports are healthy2. switchShow查看交换机
2、基本配置信息Enter the switchShow command, which displays the following information for a switch:- switchname - The switch name.- switchtype - The switch model and firmware version numbers.- switchstate - The switch state: Online, Offline, Testing, or Faulty.- switchrole - Displays the switch role: Princip
3、al, Subordinate, or Disabled.- switchdomain - Displays the switch Domain ID.- switchid - The embedded port D_ID of the switch.- switchwwn - The switch World Wide Name.- switchbeacon - The switch beaconing state: either ON or OFF.The switchShow command also displays the following information for port
4、s on the specified- Module type - The SFP type if an SFP is present.- Port speed - The speed of the Port (1G, 2G, 4G, N1, N2, N4, or AN). The speed can befixed, negotiated, or auto-negotiated.- Port state - The port status.- Comment - About the port. This section may be blank or display the WWN for
5、an F_Port oran E_Port, the trunking state, or upstream or downstream status3. portShow查看端口状态 switch:user portshow 0portName:portHealth: OFFLINEAuthentication: NoneportDisableReason:portCFlags: 0x1portFlags: 0x4001 PRESENT U_PORT LEDportType: 4.1portState: 2 OfflineportPhys: 2 No_ModuleportScn: 0port
6、 generation number:portId: 010000portIfId:portWwn: 20:00:60:69:02:53portWwn of device(s) connected:Distance: normalportSpeed: N2GbpsLE domain:Interrupts: 0 Link_failure: 0 Frjt:Unknown: 0 Loss_of_sync: 0 Fbsy:Lli: 0 Loss_of_sig:Proc_rqrd: 0 Protocol_err:Timed_out: 0 Invalid_word:Rx_flushed: 0 Invali
7、d_crc:Tx_unavail: 0 Delim_err:Free_buffer: 0 Address_err:Port part of other ADs: Yes4. fanShow查看交换机散热风扇的状态Enter the fanShow command: fanshowFan 1 is OK speed is 7010 RPMFan 2 is OK speed is 7180 RPMFan 3 is OK speed is 7068 RPMFan 4 is OK speed is 7116 RPMFan 5 is OK speed is 7155 RPMFan 6 is OK spe
8、ed is 7001 RPM5. psShow查看交换机的电源状态注:如果安装FR4-18i、FC4-16IP、FC10-6、FC8-48板,需要满配4个电源Enter the psShow command: psshowPower Supply #1 is OK0335,FF2Z0007161,60-0000739-02, B,DCJ3002-01P, B,FF2Z0007161Power Supply #2 is faulty0335,FF2Z0007176,60-0000739-02, B,DCJ3002-01P, B,FF2Z00071766. tempShow查看交换机的环境温度En
9、ter the tempShow command: tempshowIndex Status Centigrade Fahrenheit-1 OK 21 702 OK 22 723 OK 29 844 OK 24 755 OK 25 777. errDump、errShow、errClear查看交换机的内部消息日志To display the system message log, with no page breaks Enter the errDump command.To display the system message log one at a time Enter the err
10、Show command.To clear the system message log Enter the errClear command.8. supportShow、supportSave、pdShow收集交换机的诊断数据supportShow 显示诊断信息和状态信息supportSave将数据打包、上传至指定的FTP服务器The command prompts for an FTP server, packages the following files, and sends them to the specified server: The output of the suppor
11、tShow command The contents of any trace dump files on the switch System message logs (for Brocade directors, supportSave saves the system message logsfrom both of the CP blades)pdShow 显示panic dump文件的内容,帮助诊断系统panic的原因9. nsShow、nsAllShow、fabricShow检查连接到交换机的设备nsShow 显示连接到交换机的所有设备nsAllShow 显示连接到Fabric的所
12、有设备fabricShow 显示Fabric中的所有交换机10. licenseShow、wwn检查license文件和交换机的WWN号11. version检查Fabric OS的版本,将显示如下信息:- Kernel: displays the version of switch kernel operating system.- Fabric OS: displays the version of switch Fabric OS.- Made on: displays the build date of firmware running in switch.- Flash: displ
13、ays the install date of firmware stored in nonvolatile memory.- BootProm: displays the version of the firmware stored in the boot PROM.12. haShow查看Control Blade的状态swDir: admin haShowLocal CP (Slot 6, CP1): Active Remote CP (Slot 5, CP0): Standby HA Enabled, Heartbeat Up, State Synchronized13. slotSh
14、ow查看各个Blade的状态14. portCfgSpeed修改端口的速率15. portEnable或portCfgPersistentEnableReset端口16. 检查WWN卡状态下列命令如果不能正确执行,则说明WWN卡需要更换:www,chassisShow:显示交换机的WWN号chassisShow:显示chassis和WWN卡的状态ipAddrShow,ipAddrSet:显示CP Blades的IP地址historyShow、historyLastShow:显示历史日志信息switchName:显示交换机的名字修改Domain ID1. 查看当前的Domain ID输入命令fabricShow,输出结