1、urban sewage treatment plant pollutant discharge standard (GB18918-2002) of a standard B emission. Because the sewage originates is mainly the sanitary sewage, the nitrogen phosphorus content is high, from this designs needs to consider the denitrogenation eliminates the phosphorus. This factory sec
2、ond-level biological treatment mainly uses a2/O processing craft, the main construction is: Before the pump, the grill, promotes the pump house, the thin grill, the eddy sand collector, the advection type sedimentation pond, a2/O response pond, the spoke class type sedimentation pond, the ultraviole
3、t ray disinfection ditch. The sludge treatment construction includes: Gravity concentration basin, sludge dewatering engine room and so on. The process of the wastewater plant that the wasterwater treatment plant adopted is as following:Wastewater treatment process: middle bar screen pump station fi
4、n bar screen aeration desilting tank A/O process disinfection of contact poolmeasurement groove drain;Sludge handling and disposal process: excess activated sludge concentrated pool sludge tank machine dewatering disposal of sludge cake.Key words: sludge conditioning; A2/O craf ; Nitrogen and phosph
5、orus removal总 目 录第一卷 第一册 设计说明书第二卷 第二册 工程概算书第三卷 第三册 工程图初步设计武汉科技大学城市学院设计研究所 二零一三年五月(武汉)院 长:总工程师:审定人 :顾问总工:室 主 任:项目负责人:参加编制人员:1.设计任务及概况1.1 设计任务及依据1.1.1 设计任务 北方某市污废水处理工程 按照上级批准的设计任务书规定,完成某市的城市污水处理厂的设计。包括厂区内的污水处理工程、污泥处理工程以及其它附属建筑工程等。要求经过处理后的水能够达到城镇污水处理厂污染物排放标准要求。1.1.2 设计依据及原则 1.1.2.1 设计依据1、污水综合排放标准(GB897
6、8-1996)2、城镇污水处理厂污染物排放标准(GB18918-2002)3、城市污水处理厂污水污泥排放标准(GJ3025-93)4、城镇污水处理厂附属建筑和附属设备设计标准(CJJ31-89)5、城市污水处理及污染防治技术政策6、城市污水处理工程项目建设标准7、废水水质水量资料某市城市人口60万,城市居民平均用水400L/人d,日排放工业废水30000m3/d,具体水质资料如下:城市生活污水:CODCr 400mg/L,BOD5 200mg/L,SS 200mg/L,NH4-N 40mg/L,TP 8mg/L,pH 68;工业废水:CODCr 800mg/L,BOD5 350mg/L,SS
7、400mg/L,NH4-N 80mg/L,TP 12mg/L,pH 68。污水处理厂出水按城镇污水处理厂污染物排放标准(GB18918-2002)的一级B标准排放,主要排放指标为CODCr 60mg/L,BOD5 20mg/L,SS 20mg/L,TN 20mg/L,NH4-N 8mg/L,TP 1mg/L。8、气象、水文与工程地质资料该市气候温和,地质条件较好。污水进水口管道标高116.00m,污水处理厂地面标高为124.00m,附近河流的最高水位为122.40m。1.1.2.2 设计原则(1)执行国家关于环境保护的政策,符合国家地方的有关法规、规范和标准; (2)采用先进可靠的处理工艺,确
8、保经过处理后的污水能达到排放标准; (3)采用成熟 、高效、优质的设备,并设计较好的自控水平,以方便运行管理; (4)全面规划、合理布局、整体协调,使污水处理工程与周围环境协调一致;(5)妥善处理污水净化过程中产生的污泥固体物,以免造成二次污染;(6)综合考虑环境、经济和社会效益,在保证出水达标的前提下,尽量减少工程投资和运行费用。1.2设计水量及水质1.2.1设计水量 1、平均污水量QP1的计算(1)生活污水量QP1的计箅(根据人口)QP1=Nq0.8式中:N人口数,60万人q一居民用水定额,北方某中型城市,q为400L/capd0.8排放系数(0.80.9),取0.8QP2=600000x
9、400x0.8=192000m/d(2)工业废水量:QP1=30000m(3)平均日污水量Qp=QP1+QP2=192000+30000=226000 m为安全考虑设计水量采23万 m(4)最高口污水量Qmr=QPK日=2300001.1=253000 mQmax=QPK总=2300001.3=299000m各水量见表1.1表1.1 设计水量一览表项 目设计水量m/h/sl/s平均日流量2300009583.332.662662.0最高日流量25300010541.672.933182.9最高时流量29900012458.333.463460.71.2.2设计水质设计水质如表1.1所示。表1.
10、1 设计水质情况 CODcrTPNH3-N入水()220.27 454.05 227.038.5445.41出水()20 60 1 8 去除率(%)90.986.891.288.382.4进水水质1、BOD5(1)、生活污水的BOD5Cs=200mg/L(2)工业废水的BOD5由资料可知:Cg=350 mg/L(3)平均的BOD5Ca=(200192000+35030000)/222000=220.27mg/L2、COD(1)生活污水COD=400mg/L(2)工业废水COD=800mg/L(3)混合污水平均COD=(400192000+80030000)/222000=454.05mg/L3
11、、SS(1)生活污水COD=200mg/L(2)工业废水COD=400mg/L(3)混合污水平均COD=(200192000+40030000)/222000=227.03mg/L4、TP(1)生活污水TP=8mg/L(2)工业废水COD=12mg/L(3)混合污水平均COD=(8192000+1230000)/222000=8.54mg/L5、NH3-N(1)生活污水COD=40mg/L(2)工业废水COD=80mg/L(3)混合污水平均COD=(40192000+8030000)/222000=45.41mg/L去除率E=(C0-Ce)/ C0100%C0:进水浓度Ce:出水浓度2 城市污
12、水处理方案的确定2 城市污水处理方案的确定2.1 确定污水处理方案2.1.1 确定污水处理方案的原则(a)城市污水处理应采用先进的技术设备,要求经济合理,安全可靠,出水水质好;保证良好的出水水质,效益高;(b)污水厂的处理构筑物要求布局合理,建设投资少,占地少;自动化程度高,便于科学管理,力求达到节能和污水资源化,进行回用水设计;(c)为确保处理效果,采用成熟可靠的工艺流程和处理构筑物;提高自动化程度,为科学管理创造条件;(d)污水处理采用生物处理,污泥脱水采用机械脱水并设事故干化厂;污水采用季节性消毒;(e)提高管理水平,保证运转中最佳经济效果;充分利用沼气资源,把沼气作为燃料;(f)查阅相
13、关的资料确定其方案。2.1.2 最佳的处理方案要体现以下优点:(a)保证处理效果,运行稳定;(b)基建投资省,耗能低,运行费用低;(c)占地面积小,泥量少,管理方便。2.2 污水处理工艺流程方案介绍现阶段城市污水处理应用的多是生物处理系统,应用较多的工艺有A2/O、氧化沟,及传统活性污泥法,现对这三个工艺进行比较,选出最合适的工艺。2.2.1 传统活性污泥法其工艺流程见图1。二沉池曝气池初沉池沉砂池格栅 出水 回流污泥 剩余污泥图1 传统活性污泥法工艺流程图活性污泥法处理城市污水的典型工艺,其特点是好氧微生物在曝气池中以活性污泥的形态出现,并通过鼓风机曝气供给微生物所必需的足够氧量,促使微生物生存和繁殖以分解污水中的有机物。
copyright@ 2008-2022 冰豆网网站版权所有