1、ABSTRACTThe design entitled Xuanhua a woolen mill wastewater treatment process design, The works are mainly treated sewage effluent from dyeing and washing lines, washing blankets, embroidery workshop wastewater components. Confirmed by the construction side, the design of handling the largest-scale
2、 water daily : 2500 cubic meters per day (including water discharge from the station). Sewage major pollutants CODcr, SS, BOD5, S2-, color, the effluent quality are as follows : dyeing wastewater : CODcr=1495mg/L, BOD5=340mg/L, SS=540mg/L. S2-=1.35-2.16mg/L, pH=3.7-8.62, color 300 times; washing lin
3、e, washing blankets, embroidery workshop wastewater:CODcr=480mg/L, BOD5=300mg/L. SS=200mg/L, S2-=1.2mg/L, PH=3.7-8.62. color 50 times. The average winter temperature -14.9 , average summer temperature of 29.2 , with the average rainfall 427.1mm. Winter winds led to the northwest, the summer winds le
4、d to the southeast. Water Disposal Station : BOD5 20mg/l, CODcr 100mg/l, SS 70mg/l, PH=6-9, color 50, the effluent quality in the states two emission standards. The design acid hydrolysis Biological oxidation wastewater treatment. Dealing with the main structures regulation pool, pool acid hydrolysi
5、s, biological oxidation pond, the vertical flow sedimentation tank, concentrated pool, pumping stations, Dehydration room and the other blower. The main structures of biological oxidation pond used for the traditional contact-oxidation, using a total of two, each divided into eight blocks. significa
6、nt treatment effect. Pretreatment Regulation pools and pool acid hydrolysis effectively reduce the sewage indicators of biological oxidation pond inundated. Intake provides the best indicator, but also effectively reduce sewage color, plus behind the vertical flow sedimentation tank of flocculation
7、and sedimentation, color indicators greatly reduced. Basically meet water requirements. Keywords : dyeing wastewater wastewater treatment biological oxidation 第1章 概述1.1设计依据及设计任务1.1.1设计题目宣化某毛纺厂废水处理工程工艺设计1.1.2设计依据1、国家污水综合排放标准(GB8978-1996)2、地面水环境质量标准(GB3838-88)3、室外排水设计规范(GBJ14-87,97年修订版)4、城镇污水处理厂附属建筑和附
8、属设备设计标准(CJJ31-89)5、板框压滤机污水污泥脱水设计规范(CECS75:95)6、水质、水量、厂址、地质等基础设计资料7、环境工程专业毕业设计任务书a.污水量:1500m3/d800 m3/db.污水水质:CODcr=1495mg/LBOD5=340mg/LSS=540mg/LS2-=1.35-2.16mg/LPH=3.7-8.62色度=300倍CODcr=480mg/LBOD5=300mg/LSS=200mg/LS2-=1.2mg/L色度=50倍c.出水水质:CODcr100 mg/LBOD520 mg/LSS70 mg/LS2-0.5mg/LPH=6-9色度50倍d.气象资料:
9、工程所在地属温带大陆气候,四季分明,冬春季节干旱,盛行西北风,风沙大,降雨少。冬季寒冷,夏季比较炎热,降雨量集中,秋季明朗,日照充足,是一年中的黄金季节。主要气象条件如下:气 温: 年平均温度: 7.8 极端最低气温:-25.7 极端最高气温:40.9 最冷月一月份平均气温:-14.9 最热月七月份平均气温:29.2年平均降水量:427.1mm日最大降水量:100.4mm一小时最大降水量:75.9mm风 向:冬季主导风向:西北;夏季主导风向:东南水 位:地面下:6.0-7.5m冻土深度:最大冻土深度:1360mme.工程地质资料:地质情况:一层:耕植土,暗褐,松散。 二层:轻亚粘土,黄褐,稍密
10、,软塑。三层:亚粘土,褐色,稍密,软塑。四层:粉粘土,灰色,很湿到饱和。五层:淤层亚粘土,灰色,稍密,软塑。地耐力:-1.00地耐力基本值为12吨/平方米。地下水位:地下水位为-12.0米地震烈度:7度。1.2设计水量1.3处理程度满足国家二级排放标准。表一:进出水质一览表BOD5(mg/L)CODCr(mg/L)SS(mg/L)S2(mg/L)PH色度进水134014955401.352.163.78.62300进水24802001.250出水20100700.5691.4去除率由于调节池的作用,两种水混合后的各种指标为:CODcr :BOD5 :SS :S2- :色度 :去除率公式为:式中
11、:C0进水物质浓度;Ce出水物质浓度。(1)BOD5去除率:;(2)CODcr去除率:(3)SS去除率:(4)S2-去除率:(5)色度去除率:第2章 污水处理站方案的确定2.1确定污水处理方案的原则a.确定污水处理方案的原则:1污水处理应采用先进的技术设备,要求经济合理,安全可靠,出水水质好;保证良好的出水水质,效益高;2污水处理站的处理构筑物要求布局合理,建设投资少,占地少;自动化程度高,便于科学管理,力求达到节能和污水资源化,进行回用水设计;3.为确保处理效果,采用成熟可靠的工艺流程和处理构筑物;提高自动化程度,为科学管理创造条件;4.污水处理采用生物处理,污泥脱水采用机械脱水;5.提高管
12、理水平,保证运转中最佳经济效果;6.查阅相关的资料确定其方案。b.最佳的处理方案要体现以下优点:1.保证处理效果,运行稳定;2.基建投资省,耗能低,运行费用低;3.占地面积小,泥量少,管理方便。2.2 污水处理方案的确定根据测量的水量、水质和环境容量降低的结论确定污水及污泥处理应达到的标准,本节对其处理工艺流程进行方案筛选,并通过论证选择合理的污水及污泥处理工艺流程。2.2.1处理标准的确定BOD5=326mg/l; CODcr=1141mg/l; SS=421mg/l;S2=1.7mg/l; PH=3.78.62; 色度=213;气温:年平均气温7.8;夏季平均气温29.2;冬季平均气温 -14.9。2.2.2污水处理路线选择我国污水处理在建国四十多年来取得是很大的成就,污水处理技术随着水污染控制及环境治理的实践,在吸取国外技术经验的同时,结合我国国情的特点,逐步改进提高,初步形成了一些适用的技术路线,主要如下:a.对传统活性污泥法进行改造或予以取代后的人工生物
copyright@ 2008-2022 冰豆网网站版权所有