1、室内设备平面布置图包括信号电源室、防雷分线室、机械室、控制台室,计算机房内各种设备的布置。工程数量统计表统计的是34号站下行咽喉所需要的所有电缆线、信号机、盒子、柜子、道岔、轨道、继电器等的数量。关键词:计算机联锁;工程设计;联锁表;极性交叉;继电器- I -AbstractComputer interlocking system is following the 6502 Electric system yet another interlocking system , which guarantees reliable work is to ensure traffic safety si
2、gnal infrastructure, in line with fail - safe principle. Interlocking is currently the most advanced computer station interlocking equipment , Chinas transition from a centralized computer interlocking relays are electrically developed .The design of electro-chemical sector into line No. 34 Portland
3、 station downstream of the throat computer interlocking engineering design , design of the main contents include : No. 34 station downstream of the throat of the station signal floorplan , downstream of the throat interlocking table , double track circuit layout, cable network diagrams, cable route
4、maps, computer interlocking system structure diagram , a list row combination , the combination of the type of table , interior equipment layout , engineering and quantity statistics. Station signal floorplan which can reflect the intuitive arrangement of outdoor equipment , the main signal , turnou
5、t , police rushed the underlying layout, calculating numbers and locations. Interlocking table includes direction , into the road , buttons, signal , switch , hostile signals and track sections to determine the selection and so on. Double track circuit diagram is mainly done by sending electrical te
6、rminal settings , layout choke transformer , polarity cross track circuit configuration . FIG FIG cable network and the main pathway is reasonable laying cable length calculation , calculation of the number of cable cores , is mainly based on the construction of trench . Computer interlocking system
7、 structure reflects the hardware configuration hot standby system used and how it works . List reflects a combination of row arrangement of the signal cabinet, track cabinets, counters and composition of the turnout . Combination Type table contains the names and types of various combinations of rel
8、ays included . Indoor equipment layout plan including room layout signal power , lightning -point line room, mechanical room , the console room, computer room various devices. Quantity is the number of statistical tables works all 34 cable stations downstream of the throat needed , signal boxes , ca
9、binets, switches, track, relays , etc.Key Words: Computer Interlocking, Engineering Design, Interlocking Table, Polar cross, Relay目 录摘 要IAbstractII1 绪论11.1设计的主要技术标准11.2 设计的研究现状11.3 设计的主要内容12 车站信号平面布置图22.1 信号机的设置22.1.1 进站信号机22.1.2 出站信号机22.1.3 调车信号机32.2 转辙机的设置32.3 绝缘节的设置32.4 坐标计算42.4.1 道岔的坐标42.4.2 警冲标
10、的坐标42.4.3 信号机的坐标42.4.4 绝缘节的坐标42.4.5 股道有效长度的计算43 联锁表的编制53.1 方向栏与进路号码栏53.2 进路栏和按钮栏53.2.1 列车进路53.3.2 调车进路53.3.3 按钮栏53.3 道岔栏53.4 敌对信号栏63.5 轨道区段栏63.9 迎面进路和其他联锁栏64 双线轨道电路图74.1 轨道电路极性交叉74.2 轨道电路送受电端的布置74.3 跳线与区间连接线的布置84.4 扼流变压器的布置95 电缆径路图和电缆网络图105.1 电缆径路的选择105.2 电缆网络连接设备与构成105.2.1 电缆网络连接设备105.2.2 信号电缆网络105
11、.2.3 道岔电缆网络115.2.4 送受电端电缆网络115.3 电缆网络计算115.3.1 电缆类型的选择115.3.2 电缆长度的计算115.4 电缆芯数的计算125.4.1 基本芯125.4.2 附加芯125.4.3 备用芯126组合排列及类型表136.1 组合排列表136.1.1 信号组合136.1.2 道岔组合136.1.3 轨道组合136.2 组合类型表147系统结构图和室内设备布置图157.1 计算机联锁系统结构图157.1.1 控制台157.1.2 电务维护台157.1.3 联锁机157.1.4 ET机架157.1.5 微机检测机157.1.5 电源167.2 室内设备布置图1
12、67.2.1 信号计算机房设备167.2.2 信号机械室设备167.2.3 信号电源室设备167.2.4 防雷分线室设备167.2.5 控制台室设备168 工程数量统计表178.1 建筑工程178.1 安装工程178.1 计算机联锁工程17结 论19致 谢20参考文献21- V - 21 -1 绪论1.1设计的主要技术标准本设计为电化区段兰成线34号站下行咽喉计算机联锁工程设计。有4股道,道岔6组,正线12#60kg道岔,侧线分为12#50kg道岔、9#50kg道岔两种,站内电码化设计,区间为复线双向运行,正向为自动闭塞,反向为站间自动闭塞。同时设有一条专用线和一条货物线,其中I、II股道有超
13、限货物列车通过。该站区段按电气化区段要求设计,车站联锁按照计算机联锁工程设计标准设计。1.2 设计的研究现状1987年瑞典首先在歌德堡车站使用了计算机联锁系统,后来一些发达的国家也陆续的使用了计算机联锁系统。在我国,1984年铁道部通信信号总公司研究设计院研制的计算机联锁系统投入厂矿铁路使用。我国当前的计算机联锁系统已经处于可用阶段,但是在可靠性和功能方面都有待以提高1。2000年,我国成功研制了适合我国铁路运输的 K5B型计算机联锁系统。计算机联锁技术在我国铁路迅速推广,新建铁路、既有线改造均已采用计算机联锁,而且主要干线、客运专线、高速铁路还必须采用二乘二取二或三取二型计算机联锁2。1.3 设计的主要内容(1) 设计34号站下行咽喉车站信号平面布置图;(2) 编制34号站下行咽喉联锁表;(3) 设计34好站下行咽喉双线轨道电路布置图;(4) 设计34号站下行咽喉电缆网络图;(5) 设计34号站下行咽喉电缆径路图;(6) 设计K5BMC型计算机联锁系统结构图;(7) 编制34号站下行咽喉组合排列表;(8) 编制34号站下行咽喉组合类型表;(9) 设计34号站室内信号设备平面布置图;(10) 编制34号站下行咽喉工程数量