信息化标准机房运维管理方案.docx
《信息化标准机房运维管理方案.docx》由会员分享,可在线阅读,更多相关《信息化标准机房运维管理方案.docx(33页珍藏版)》请在冰豆网上搜索。
信息化标准机房运维管理方案
信息化标准机房
运
维
管
理
方
案
2017 年 5 月
一、 概述 .......................................................................................................................................1
二、 维护职能划分 .......................................................................................................................1
三、 供配电系统 ...........................................................................................................................1
3.1日常巡检内容 .....................................................................................................................1
3.2巡视检查频次 .....................................................................................................................2
3.3维护保养 .............................................................................................................................2
3.3.1月维护 .............................................................................................................................2
3.3.2季维护 .............................................................................................................................2
3.3.3年维护 .............................................................................................................................3
3.4巡视检查注意事项 .............................................................................................................3
四、 UPS 系统 ................................................................................................................................4
4.1UPS 的日常巡检 ..................................................................................................................4
4.2巡检频次 .............................................................................................................................4
4.3UPS 设备维护保养 ..............................................................................................................4
4.3.1月维护 .............................................................................................................................4
4.3.2季度维护(主要进行放电测试)......................................................................................5
4.3.3半年维护 .........................................................................................................................5
4.3.4年检维护(主要进行电气部件紧固操作)......................................................................5
五、 精密空调系统 .......................................................................................................................6
5.1日常巡检内容 .....................................................................................................................6
5.2日常巡检频次 .....................................................................................................................6
5.3维护保养 .............................................................................................................................6
5.3.1季度维护 .........................................................................................................................6
5.3.2半年维护(春秋季换季维护)。
......................................................................................7
六、 新风系统 ...............................................................................................................................7
6.1巡检内容 .............................................................................................................................8
6.2巡检频次 .............................................................................................................................8
6.3维护保养 .............................................................................................................................8
七、 应急发电系统 .......................................................................................................................8
7.1巡检内容 .............................................................................................................................8
7.2巡检频次 .............................................................................................................................9
7.3应急发电设备维护保养 .....................................................................................................9
7.3.1月保养(空载启动) .........................................................................................................9
7.3.2季度保养 .......................................................................................................................10
7.3.3半年保养 .......................................................................................................................11
7.3.4年度保养 .......................................................................................................................11
7.3.5每二年保养 ...................................................................................................................11
八、 安防系统 .............................................................................................................................12
8.1巡视检查内容 ...................................................................................................................12
8.2巡视检查频次 ...................................................................................................................12
8.3保养维护 ...........................................................................................................................13
8.3.1月维护 ...........................................................................................................................13
8.3.2季度维护 .......................................................................................................................13
九、 消防灭火系统 .....................................................................................................................14
9.1巡视检查内容 ...................................................................................................................14
9.1.1消防灭火系统 ...............................................................................................................14
9.1.2安全疏散设施 ...............................................................................................................14
9.1.3消防器材 .......................................................................................................................14
9.2巡视检查频次 ...................................................................................................................15
9.3保养维护 ...........................................................................................................................15
9.3.1月维护 ...........................................................................................................................15
9.3.2季度维护 .......................................................................................................................15
9.3.3半年维护 .......................................................................................................................16
9.3.4年维护 ...........................................................................................................................16
十、 相关表格 .............................................................................................................................17
一、 概述
基础设施管理主要是对各类基础设施设备的巡检、监控、维护、
操作,本体系制定了上述内容的具体方法及相关要求。
本体系指定
的目标是保障机房基础设施、设备正常、安全、可持续运行,规范
日常运行管理工作,对保障机房正常使用环境的设备运行进行有效
监控。
本体系适用于基础设施各相关岗位。
二、 维护职能划分
日常巡检工作内容应由机房值班人员负责,巡检结束后填写
《日常巡检记录表》。
维护保养工作应由专业分包服务人员实施,维护保养结束后及
时填写维护保养记录,并应由机房运维岗位负责人签字确认。
原则上 UPS 及精密空调的维护应由设备厂商专职工程师实施。
三、 供配电系统
供配电系统是指通过电源由多种配电设备(或元件)和配电设施所组
成直接向终端用户分配电能的一个电力网络系统。
是对低压配电柜、
UPS 系统等的统称。
3.1日常巡检内容
供配电系统日常巡检内容包括:
(1)配电室环境温度、洁净度,注意有无异味、异常声响等;
(2)查看各个开关的仪表显示应正常;
(3)查看各开关状态确认无误;
(4)检查各开关有无异常声响、变形;
1
(5)用点温仪测量开关温度并记录;
(6)检查变压器温度、声音、电压、电流、风机启动有无异常;
(7)日常巡检工作由值班人员进行,巡检状况因记录在《日常巡
检记录表中》;
3.2巡视检查频次
每日一次。
3.3维护保养
3.3.1 月维护
a)清洁设备表面和场所的卫生;
b)对日常维护记录中反映出来的主要数据的变化规律进行分析,
发现异常要进行调整或检修;
c)检查转动和震动部件,紧固其不应松动的紧固件(不包括电气
接点,电气接点的维护、紧固应有计划的停电进行);
d)由分包服务责任人按规定填写《供配电系统维护记录表》。
3.3.2 季维护
供配电系统季维护属于部分检修性维护,应根据具体情况对相
关设备停电后进行。
a)完成设备的月维护工作。
b)针对日巡视及月巡视相关记录对负荷量较大及负荷变化较大
的线路及开关接线处进行检查,对松动部件进行紧固。
紧固工作应
停电进行,停电前注意确认,以防误操作。
c)对配电柜进行全面除尘,除尘应使用专用工具,并且工作人
2
员不可踩踏配电箱柜。
d)分包服务负责人按规定填写《供配电系统维护记录表》。
3.3.3 年维护
年维护属于预防性维护,应停电进行。
a)完成设备的季度维护工作。
b)清扫变配电设备内外卫生。
c)检查电器元件的操作机构是否灵活,不应有卡涩或操作力过
大现象。
d)检查主要电器的主辅触头的通断是否可靠。
e)检查各母线的连接、绝缘支撑件、安装件、其它附件安装是
否牢固可靠。
f)由分包服务责任人按规定填写《供配电系统维护记录表》。
3.4巡视检查注意事项
(1)巡检时必须严格遵守各项安全运行工作制度。
(2)巡检时应禁止带手表、手链等金属物件。
(3)巡检时应携带对讲设备以保持通讯畅通。
(4)巡检应二人进行,巡检完成后应向机房运维岗位负责人汇报
巡检情况。
(5)巡检时必须严格执门禁管理方面的规定,只在授权区域内进
行巡检。
(6)在巡检中发现设施或设备工作异常时,应立即向机房运维岗
位负责人汇报并按照机房运维岗位负责人的安排进行处理,协助机
3
房运维岗位负责人或相关人员填写相关报告。
四、 UPS 系统
UPS(Uninterruptib1e Power Supply)意为“不间断供电电源’’,
是一种含有储能装置(常见的是蓄电池),以逆变器为主要组成部分
的恒压恒频的交流供电设备。
4.1UPS 的日常巡检
(1)检查卫生环境、温湿度状况;
(2)检查 UPS 运行状态,记录各种运行数据,包括电压、电流、频率、
功率、带载率等;
(3)观察 UPS 风扇有无异响,运行是否正常;
(4)观察 UPS 主机内部有无异响、震动;
(5)观察 UPS 输入、输出柜各进出线开关状态(检查项同普通开关柜);
(6)观察电池外观有无明显鼓胀、渗液或开裂;
(7)日常巡检工作由值班人员进行,巡检状况因记录在《日常巡检记
录表中》;
4.2巡检频次
每日一次。
4.3UPS 设备维护保养
4.3.1月维护
a)除进行日常检查之外,还应检查 UPS 通风风扇是否完好,风
扇电机无卡死、抱轴情况,风扇扇叶完好无损。
4
b)风扇滤网干净,无灰尘堆积,发现不合格及时更换。
c)记录 UPS 电压、电流、负载率相关参数。
d)检查 UPS 报警情况,将 UPS 报警记录统计分析,判断 UPS 本
身是否存在问题。
e)测量并记录电池组内阻、静态电压。
f)分包服务负责人填写《UPS 系统维护记录》。
4.3.2季度维护(主要进行放电测试)
a)除进行月维护的项目外,还应对 UPS 的电池进行放电。
b)电池组应放电至额定容量的 60~70%,并记录放电后再次充满
时的后备时间。
c)不可同时对相同负荷的两路 UPS 进行放电,且放电测试间隔
应大于 48 小时。
d)分包服务负责人填写《UPS 系统维护记录》。
4.3.3半年维护
a)除进行季度检查的项目外,还应对 UPS 设备进行整体除尘。
b)除尘应使用真空式吹风机,不能使用湿抹布。
c)分包服务负责人填写《UPS 系统维护记录》。
4.3.4年检维护(主要进行电气部件紧固操作)
a)除进行 UPS 半年检的项目之外,还应对整体 UPS 设备进行紧
固操作。
b)联系 UPS 厂家对 UPS 的内部参数进行校对,对内部器件进行
检查测试。
5
c)年检操作必须关机进行,关机后应对 UPS 内部进行放电操作。
d)由于旁路仍有部分带电,应对带电部分作出明显标记,以警
示维护人员。
e)分包服务负责人填写《UPS 系统维护记录》。
五、 精密空调系统
机房精密空调是针对现代电子设备机房设计的专用空调,它的
工作精度和可靠性较高。
5.1日常巡检内容
(1)记录设备机房内的回风温、湿度;
(2)查看空调机有无异响;
(3)制冷剂充注量是否合适(可以通过观察视液镜中