纸箱测试报告.docx
《纸箱测试报告.docx》由会员分享,可在线阅读,更多相关《纸箱测试报告.docx(32页珍藏版)》请在冰豆网上搜索。
纸箱测试报告
纸箱测试报告
Thetestreport
Thesampleinformation
Thesamplename:
carton
Samplenumber:
1-5
Samplemodels:
100*100ml
Sampletype:
AB
Samplesize:
479*247*280mm
Samplequantity:
5
Sample:
normal
ThetestinformationTestproject:
insidediameter,outsidediameter,shakecoveraperture,shakecoverdislocation,thethicknessofthecardboard,cardboardg,shakecoverfolding,marginalpressurestrength,burststrength,compressionchamber,watercontent,theprintingiswiped,connectionstrength
Receiveddate:
2015-08-30
Thetestdate:
2016-03-10
Testenvironment(23+/-1)℃,(50+2)%RH
Figure1corrugatedcartonsamplefigure
Testingproject1:
innerdiameter,outsidediameter
1.Theteststandard:
no
2.Testequipment:
standardsteelruler
3.Testmethod:
3.1holdupformeasurementofthecarton,thebottomshakecoverfoldintotheinside,onaflat,smoothsurfaceismeasured.
3.2measuringinnerdiameterlengthbetweentheplateonbothsidesofthebox,steelrulerasfaraspossiblewillbetightlengthdirectiononbothsidesofthecartonboard,firstinthesideofthecartonboardfixedsteelruler,zeroitstretchtotheothersideoftheplate,keepparallelwithcartonboard,readthemeasurementresults.
Measuringinnerdiameter3.3onbothsidesoftheboxinthewidthdirectionboardwidthsize,feetasfaraspossiblewillbetightwidthonbothsidesofthecartonboard,aspreviouslydescribedstepwidthmeasurementresults.
3.4shakeonbothendsofthecoverfolded,measuringinnerdiameterheightofthecartonbetweenrollcoveronbothends.Whenmeasuringthefootagainstthewall,atthebottomoftherollcoverfixedruler,zeroalongthecaseboardstraightfeetfirstcovertheroots,keepthefeetclosetothechestwall,keeptheverticalpositionaccurately,readthemeasurementresults.
3.5outsidediametermeasurementintheASTMstandard,thereisnodetaileddescription,referringtothemeasurementofinnerdiameter,firstfixedsteelrulerzeroatoneend,thenextendedtotheothermeasurements.
4.Thetestdetails:
4.1thetestingprocess
:
(1)samplingtotestsamplesprovidedbythecompanyfoldedneatly,temporarilynottopandbottomrockcoverseal.
(2)test:
accordingtotheabovetestmethodshowsthestepsinthemeasuredthecartonsinsidediametersizeoflength,widthandheight,length,widthandheightandthenmeasuringdiametersize.
4.2thetestdata
Measurementdataisaccurateto1mm,eachdirectionshouldbemobilepositionmeasuringatleastfivesetsofdata,recordsinthetable.
(a)(b)(c)
FIG.1-1diametertestphotos
Table1-1diametertestresults
unit:
mm
times
Items
1
2
3
4
5
averagevalue
length
468.1
468.1
470.2
469.1
471.1
469.3
wide
237.1
238.2
237.2
238.1
237.0
237.5
high
263.1
262.0
263.0
262.1
262.2
262.5
(a)(b)(c)
Figure1-2diametertestphotos
Table1-2diametertestresults
unit:
mm
times
items
1
2
3
4
5
averagevalue
length
483.1
482.0
484.0
484.0
484.0
483.4
wide
246.1
244.0
246.1
248.0
247.0
246.2
high
269.1
270.1
269.2
268.0
268.0
268.9
Testitem2:
shakecoverthegap
1.Theteststandard:
no
2.Testequipment:
steelruler
3.Testmethod:
Gapsinthemiddlecovergapforwaveafterthecovercanbefoldedinhalf,foldingcartonsaftermolding,withthehandgentlyclosethelid,withaccuracyof1mmsteelrulertomeasurethegapsinthemiddlebottomandtopfivegroupseach,andaveraged.
4.Thetestdetails:
4.1thetestingprocess
(1)sampling:
holdupthecartonsamples,topandbottomcoverclosedgently,donottaketheexternalmediumsealing.
(2)test:
willprovidethecartonsamplesholdup,withthehandgentlyclosedthebottomcover,placedonaflat,smooththesurfaceofthetable,andthengentlyclosetheuppercover,carton,lightpressuremeasuringupperfoldedaftertworollcoverinthemiddleofthedistance.Thengentlyclosetheupperpartofthewaveinversion,dittoshakesthegapsbetweenthecoveratthebottomofthedistancemeasurement.
4.2thetestdata
Precisemeasurementresultsto1mm,topandbottomrockcoverclearanceofatleastfivesetsofdata,average.
(a)(b)
Figure2shakecoveraperturetestphotos
Table2shakecoveraperturetestresults
unit:
mm
times
items
1
2
3
4
5
averagevalue
Atthetopofthe
0.5
1.0
2.0
1.5
1.2
1.2
Atthebottomofthe
2.0
1.5
1.0
0.5
0.5
1.1
Testproject3:
shakecoverdislocation
1.Theteststandard:
no
2.Testequipment:
steelruler
3.Testmethod:
coverdislocationiswavecovercanbefoldedinhalf,bothsidesshookattheendsofthecoverlengthdirectiondisplacementdistance.Aftermolding,foldingcartons,withthehandgentlyclosedthecover,shakecovercanbefoldedinhalfclosed,measuredwithaprecisionof1mmsteelruleshakemisplacedaftercoverclosed.
4.Thetestdetails:
4.1thetestingprocess
(1)sampling:
holdupthecartonsamples,topandbottomcoverclosedgently,donottaketheexternalmediumsealing.
(2)test:
willprovidethecartonsamplesholdup,withthehandgentlyclosedthebottomcover,placedonaflat,smooththesurfaceofthetable,andthengentlyclosetheuppercover,carton,lightpressuremeasurementcanbefoldedinhalfaftertheuppertworollcoverlengthdirectionofdislocationdistance.Thengentlyclosetheupperpartofthewaveinversion,dittodistancemeasuringmisalignmentofthebottomtworollcoverlengthdirection.
4.2thetestdata
Precisemeasurementresultsto1mm,topandbottomrockcoverdislocationdistanceatleasteveryfivesetsofdata.
(a)(b)
图3摇盖错位测试照片
表3摇盖错位测试结果
unit:
mm
times
items
1
2
3
4
5
averagevalue
Atthetopofthe
4.0
5.0
3.0
4.0
3.0
3.8
Atthebottomofthe
3.0
4.5
5.0
5.0
5.0
4.5
Testitem4:
thethicknessofthecardboard
1.Theteststandard:
ASTMD645
2.Testequipment:
Devicename
unittype
equipmentnumber
Theperiodofvalidityofcalibration
Thetablepointertypethicknessgauge
GT-313-A
-
-
Adjustablepapercuttingknives
-
-
-
3.Testmethod:
3.1beforethetestonthemicrometerthicknessgaugecalibration,guaranteethepresserfootandchoppingblockbesmirch,instrumenttoplaceinafixedtable,preventthehappeningofthevibration.
3.2thelocationofthesampleplacedonthechoppingblock,tobeabletoguaranteeapointontheedgeofthecontactsurfaceofatleast6mmabovethesampleedgedistance.
3.3inallcases,eachsamplemeasuredatleastfivetimes.
3.4attheendofthestopintimetoreadthedata,ifnecessary,theresultswiththedeviationwhenthecalibration.
3.5presserfootdroprateandtostopintimewithintheprescribedscope,sidepaperboardcompressionmakesthemeasurementisnotaccurate.50+2kpapressureoffoot,tostopintimefor3+1s,presserfootdropspeedwas0.8+/-0.1mm/s.
4.Thetestdetails:
4.1thetestingprocess
(1)sampling:
cardboardsampletoboxboard,boxboardaroundcornersandcentersampling,foratotaloffivesamples,sizeis100mm*100mm.
(2)test:
firstofalltocalibrationofinstruments,adjusttheinstrumentzero,placethesamplebetweenthemeasuredsurface,tobeabletoguaranteeapointontheedgeofthecontactsurfaceofatleast6mmabovethesampleedgedistance.Testslowlyatarateof0.8+/-0.1mm/swillbeanothermeasureonfacegentlymovedtosample,payattentiontoavoidanyimpact,afterbeingindicatedvaluestability,beforetheboardissag,usuallyfinishreadingin2-4s.
4.2thetestdata
Measurementsinmm,readthedataonthemicrometer,accuratetoonedecimalplaces,recordfivesamplemeasuredresults.
Figure4boardthicknesstestphotos
Table4boardthicknesstesttable
unit:
mm
times
items
1
2
3
4
5
averagevalue
1
7.95
7.94
7.92
7.97
7.90
7.94
2
7.97
8.06
8.01
8.01
8.04
8.02
3
7.92
7.91
7.92
7.91
7.95
7.92
4
7.40
7.38
7.50
7.49
7.35
7.42
5
7.78
7.75
7.78
7.76
7.79
7.77
overallmean
7.81
Testingproject5:
cardboardg
1.Theteststandard:
ASTMD646-1996(2001).
2.Testequipment:
Devicename
unittype
equipmentnumber
Theperiodofvalidityofcalibration
electronicscales
AB204-N
-
-
electronicscales
-
-
-
3.Testmethod:
3.1whenusescalestoavoidairflow.
3.2humidityhadagreatinfluenceonthemeasuredvalueofthepapergram,beforethetestsamplemustbeintheconstanttemperatureandhumiditytestchamberprocessingmorethan24hours.
4.Thetestdetails:
4.1thetestingprocess
:
(1)samplingboardsampleboxboard,boxboardaroundcornersandcenterpartofthesampling,atotalofsamplesfrom10,sizeis100mm*100mm.
(2)test:
thelaboratoryofelectronicprecisionbalance,measured10thequalityofthesamplepiece,accuratetothreedecimalplaces.
4.2thetestdata
AccordingtotheformulatocalculateG,GthecardboardG,Mforthequalityoftheelectronicprecisionmeasurementscales.Fortensampletakearithmeticaverage,canhavetoaveragegramweightofthecartons.
Figure5cardboardgtestphotos
Table5cardboardgtesttable
times
items
Theelectronicbalancereading(g)
Cardboardg(g/m2)
1
12.9213
1292.1
2
12.8918
1289.2
3
12.8611
1286.1
4
13.0176
1301.8
5
12.9791
1297.9
6
13.0110
1301.1
7
13.0278
1302.8
8
13.0104
1301.0
9
13.0444
1304.4
10
12.8218
1282.2
mean
1295.9
Testitem6:
shakecoverfolding
1.Theteststandard:
no
2.Testequipment:
no
3.Testmethod:
Accordingtothetestrequirements,theshakecoverfoldingtestusingartificialfoldtest,doesnotinvolvefoldingtestmachine.
4.Thete