8Port SAS RAID HBA安装过程Word格式.docx
《8Port SAS RAID HBA安装过程Word格式.docx》由会员分享,可在线阅读,更多相关《8Port SAS RAID HBA安装过程Word格式.docx(18页珍藏版)》请在冰豆网上搜索。
Skippedinterfacee1000g2
Attemptingtoconfigureinterfacee1000g1...
Skippedinterfacee1000g1
Attemptingtoconfigureinterfacee1000g0...
Skippedinterfacee1000g0
ReadingZFSconfig:
done.
SettingupJava.Pleasewait...
Serialconsole,revertingtotextinstall
Beginningsystemidentification...
Searchingforconfigurationfile(s)...
Searchcomplete.
Discoveringadditionalnetworkconfiguration...
SelectaLanguage
0.English
1.French
2.German
3.Italian
4.Japanese
5.Korean
6.SimplifiedChinese
7.Spanish
8.Swedish
9.TraditionalChinese
Pleasemakeachoice(0-9),orpresshor?
forhelp:
0
Whattypeofterminalareyouusing?
1)ANSIStandardCRT
2)DECVT52
3)DECVT100
4)Heathkit19
5)LearSieglerADM31
6)PCConsole
7)SunCommandTool
8)SunWorkstation
9)Televideo910
10)Televideo925
11)WyseModel50
12)XTerminalEmulator(xterms)
13)CDETerminalEmulator(dtterm)
14)Other
TypethenumberofyourchoiceandpressReturn:
3
****************************************************************************
WelcometotheRAIDCardLiveCD.Raidprogramsarein/opt/StorMan
ToperformcommandlineRAIDCardconfiguration,run"
arcconf"
attheprompt
See"
UniformCommand-LineInterfaceUser'
sGuide"
at
under"
SunStorageTekSASRAIDHBA"
formoreinformationonusingarcconf
RebootthesystemwhendoneconfiguringRAIDlogicaldrivestoexitLiveCD
#
#cd/opt/StorMan//进入/opt/StorMan目录
#arcconf–H//查看命令
|UCLI|Sununiformcommandlineinterface
|UCLI|Version5.50(B17530)
|UCLI|(C)Adaptec2003-2008
|UCLI|AllRightsReserved
COPYBACK|togglescontrollercopybackmode
CREATE|createsalogicaldevice
DATASCRUB|togglesthecontrollerbackgroundconsistencycheckmode
DELETE|deletesoneormorelogicaldevices
FAILOVER|togglesthecontrollerautotomaticfailovermode
GETCONFIG|printscontrollerinformation
GETLOGS|getscontrollerloginformation
GETSTATUS|displaysthestatusofrunningtasks
GETVERSION|printsversioninformationforallcontrollers
IDENTIFY|blinksLEDSondevice(s)connectedtoacontroller
KEY|installsaFeatureKeyontoacontroller
MODIFY|performsRAIDLevelMigrationorOnlineCapacityExpansion
RESCAN|checksforneworremoveddrives
ROMUPDATE|updatescontrollerfirmware
SETALARM|controlsthecontrolleralarm,ifpresent
SETCONFIG|restoresthedefaultconfiguration
SETCACHE|adjustsphysicalorlogicaldevicecachemode
SETNAME|renamesalogicaldevicegivenitslogicaldevicenumber
SETPRIORITY|changesspecificorglobaltaskpriority
SETSTATE|manuallysetsthestateofaphysicalorlogicaldevice
TASK|performsatasksuchasbuild/verifyonaphysicalorlogicaldevice
#arcconfgetconfig1//查看Raid卡配置
Controllersfound:
1
----------------------------------------------------------------------
Controllerinformation
ControllerStatus:
Optimal
Channeldescription:
SAS/SATA
ControllerModel:
SunSTKRAIDINT
ControllerSerialNumber:
00947AA0806
Temperature:
52C/125F(Normal)
Installedmemory:
256MB
Copyback:
Disabled
Backgroundconsistencycheck:
AutomaticFailover:
Enabled
Defunctdiskdrivecount:
Logicaldevices/Failed/Degraded:
0/0/0
--------------------------------------------------------
ControllerVersionInformation
BIOS:
5.2-0(16732)
Firmware:
Driver:
2.2-1
(1)
BootFlash:
ControllerBatteryInformation
Status:
Overtemperature:
No
Capacityremaining:
99percent
Timeremaining(atcurrentdraw):
3days,1hours,11minutes
Logicaldeviceinformation
Nologicaldevicesconfigured
PhysicalDeviceinformation
Device#0
DeviceisaHarddrive
State:
Ready
Supported:
Yes
TransferSpeed:
SAS3.0Gb/s
ReportedChannel,Device:
0,4
ReportedLocation:
Enclosure1,Slot4
ReportedESD:
2,1
Vendor:
HITACHI
Model:
H103014SCSUN146G
A2A8
Serialnumber:
000946F4EVVEPCW4EVVE
World-widename:
5000CCA00A40742B
Size:
140009MB
WriteCache:
Disabled(write-through)
FRU:
None
S.M.A.R.T.:
Device#1
0,5
Enclosure1,Slot5
000946F2LSPEPCW2LSPE
5000CCA00A3D1ABF
Device#2
0,6
Enclosure1,Slot6
000947F68VWEPCW68VWE
5000CCA00A43CC13
Device#3
0,7
Enclosure1,Slot7
000947F5ZMEEPCW5ZMEE
5000CCA00A434153
Device#4
DeviceisanEnclosureservicesdevice
2,0
EnclosureID:
Type:
SES2
ADAPTEC
VirtualSGPIO
0001
StatusofEnclosureservicesdevice
Normal
Device#5
Commandcompletedsuccessfully.
#arcconfcreate//创建LOGICALDRIVE命令列表
Usage:
CREATE<
Controller#>
LOGICALDRIVE[Options]<
Size>
<
RAID#>
Channel#ID#>
[Channel#ID#]...[noprompt]
LOGICALDRIVERVOLUME<
LD#>
[LD#]...[noprompt]
======================================================
Createanewlogicaldevice.
Options:
Additionalcreationspecifiers.
Stripesize<
STRIPE>
:
Optionalparametersforspecifyingastripesize.
STRIPEisspecifiedinkilobytes.
16,32,64,128,256*,512and1024aresupported.
Legs<
LEG>
Optionalparametersforspecifyingnumberofsub-logicaldevices.
LEGisthenumberofsub-logicaldevicesforRAIDlevel50or60.
RAID50/60:
2-16legs,3-16drives/leg,48drivesmax.
Name<
NAME>
Optionalparameterforspecifyingthenameofthelogical
device.
Priority<
PRIORITY>
InitializationPriorityforlogicaldrivecreation.
Validoptionsare:
HIGH*,MED,orLOW.
Method<
METHOD>
Initializationmethodforthelogicaldevice.
Validoptionsinclude:
BUILD,CLEAR,QUICK,and
SKIP.SKIPskipsinitialization(forrecoveryonly).
Rcache<
RCACHE>
ReadCachesettingforthelogicaldevice.
RONandROFF
Wcache<
WCACHE>
WriteCachesettingforthelogicaldevice.
WT,WB,andWBB
WT:
write-through(Disabled)
WB:
write-back(Enabled)
WBB:
write-back(Enabled)whenprotectedbybattery
Size:
Sizeofthelogicaldeviceinmegabytes.
UseMAXtosetsizetoallremainingavailablespace.
Raid#:
Raidlevelforthenewlogicaldevice.
0,1,1E,10,5,5EE,50,6,60,andvolumearesupported.
RVOLUMERaidLevelforaraidvolumelogicaldevice.
LD#Logicaldevicenumbersforthe2ormoredistinctlogicaldevices
tobeconcatenatedintotheraidvolume.
RAIDlevels0,1,and5aresupportedRVOLUMEmembers.
AllRVOLUMEmembersmustbethesameRAIDlevel.
Channel#ID#:
Alistofspace-delimitedchannelnumberand
devicenumberpairsforeachdevicetoadd
tothelogicaldevice.
noprompt:
Don'
tpromptforconfirmation.
*defaultparameterinMOSTcircumstances
#arcconfcreate1LOGICALDRIVEmax1004050607//用4,5,6,7硬盘的所有空间创建raid1+0
Doyouwanttoaddalogicaldevicetotheconfiguration?
Pressy,thenENTERtocontinueorpressENTERtoabort:
y
Creatinglogicaldevice:
Device0
devfsadm:
mkdir