VxRail超融合平台软件更新手册Word文件下载.docx
《VxRail超融合平台软件更新手册Word文件下载.docx》由会员分享,可在线阅读,更多相关《VxRail超融合平台软件更新手册Word文件下载.docx(31页珍藏版)》请在冰豆网上搜索。
EMCProject/PASID(orPartnerCompanyName):
Section3:
CustomerAccountInformation
CustomerSiteName:
CustomerContactName:
CustomerSiteStreetAddress:
CustomerSiteCity:
CustomerSiteState/Country:
Warning_DL.doc
WARNING:
DATALOSS!
Thisprocedureisdestructive.
Ifthereisanydataonthesystemthatthecustomerneeds,itmustbebackedupormigratedoffthesystempriortoperformingthisprocedure.
VxRail_Nicias4_0_100_Mobile_Build_Server_Setup.doc
VxRailv4.0.100MobileBuildServerSetup
Task
1:
VerifyBuildSystemComponents
Verifyyouhaveaccesstothefollowingbuildsystemcomponents:
Aportableserverorlaptopwiththefollowingcharacteristics:
CPU:
2coresthatsupportvirtualizationtechnology
Memory:
Atleast8GBRAM
Disk:
Atleast70GBoffreediskspace
Network:
1NIC,1dedicated1GbEthernetSwitchand4GBICadapters
A64-bitoperatingsystemthatsupportsatleastversion10ofVMwareWorkstation
∙Accesstotheinstallimageforversion10orlaterofVMWareworkstationversion10orlater.
VMwareWorkstationcanbeobtainedviaEMC’sELAwithVMware.LicensescanbeorderedthroughART.
∙AccesstotheEMCOnlineSupportsitefordownloadoftheVxRailBuildServervirtualapplianceandsoftwareimages.
2:
InstallVMwareWorkstation
11.
[
]DownloadandInstallVMwareWorkstationversion10orlater.
Figure
1VMwareWorkstationSetup
2VMwareWorkstationSetup–LicenseAgreement
3VMwareWorkstationSetup–SetupType
4VMwareWorkstationSetup–DestinationFolder
5VMwareWorkstationSetup–SoftwareUpdates
6VMwareWorkstationSetup–UserExperience
7VMwareWorkstationSetup–Shortcuts
8VMwareWorkstationSetup–ReadytoPerformRequestedOperations
9VMwareWorkstationSetup–LicenseKey
3:
DisableFirewall
DisabletheFirewallonyourlaptop.IfthelaptophasMcAfeeinstalledonit,disabletheFirewallasfollows:
21.
]LocatetheMcAfeeicon.
22.
]Right-click,gotoQuickSettings.
23.
]DisableFirewall.
10DisableFirewall
4:
EnableSettingIPAddressAutomatically
31.
]FortheConnectionportthatisconnectedtothededicated/internalbuildswitch,ensurethatIPV4issettotheObtainanIPaddressautomatically.
11TCP/IPProperties
5:
ConfigureWorkstationvirtualnetwork
TheVxRailBuildServerisavirtualappliancethatwillusethevirtualnetworksconfiguredinVMwareWorkstationtocommunicatewiththeVxRailappliancenodes.ThevirtualnetworkmustbeconfiguredbeforedeployingtheVxRailBuildServervirtualappliance.
41.
]AccesstheVirtualNetworkEditorfromtheVMwareWorkstationmainmenu.
12VMwareWorkstation–Edità
VirtualNetworkEditor
42.
]RemovethedefaultVMnet0,VMnet1andVMnet8networks
13VirtualNetworkEditor
43.
]AddVMnet10forBuildServerconnectivity.
14Select'
AddNetwork'
15Select'
VMnet10'
16SetpropertiesforVMnet10
44.
]SetthefollowingpropertiesforVMnet10:
ModifytheVMNet10settingtoNAT
Uncheck“UselocalDNS…”
SetupthesubnetIPto“192.168.254.0”.
45.
]AddVMnetVMnet11toenablebridgedconnectivity.SetVMnet11toBridgedtoenableconnectivitytothephysicalEthernetconnectionNIC.ThisNICwillbeconnectedtothededicatedEthernetswitch.
17ConfigureBridgedvirtualnetwork
18WorkstationVirtualNetworkFinalSettings
6:
DownloadVxRailsoftwarepackages
51.
]TheVxRailupdatepackageswillconsistoftheBuildServervirtualappliancearchive,andtheVxRailsoftwareupdateimages.Packagesmaybedownloadedfromandunzippedtoalocaldirectory.
PackageVersion
MD5Checksum
v4.0.100_golden_image.zip
39771828825f093fd80e4bcae1d4f366
v4.0.100_build_system.zip
f72089942c1438d3dcfde0cf0281bac6
7:
EnsureYourSystemTimeisAccurate
61.
]DisabletheFirewallonyourlaptop.IfthelaptophasMcAfeeinstalledonit,disabletheFirewallasfollows:
62.
]Ontherightcornerofthescreen,clickthetime,andclick“Changedateandtimesettings…“
19ChangeDataandTimeSettings
63.
]Inthe“DateandTime”dialog,ensurethetimeiscorrectregardingtothetimezone.
20DataandTime
64.
]Ifnot,changethetimetothecorrecttime/timezone.
Note:
Thetimezonedoesnotrequiredtobesetthesameaslocal,butthecurrenttimeregardingtothetimezonemustbesetcorrectly.
8:
DeployVxRailBuildServerVirtualAppliance
TheBuildServerisaVMwarevirtualappliance.Deploythevirtualmachinefromthevirtualmachinearchivefile.
71.
]LocatetheBuildServervirtualappliance.ThefileisinOVAformat.
72.
]DeployBuildServervirtualapplianceonVMWareWorkstation.
ClickFile
Open,andbrowsetotheBuildSystemVMpackage.
Then,followtheinstructionbelowtoimportVM.
21ImportVirtualMachine
22ImportingVirtualMachine
73.
]Right-clickthejustdeployedVMandselectSettings….
23EditSettings
74.
]ModifyMemoryforthisvirtualmachinetoatleast4096.
24VirtualMachineSettings
75.
]Configurevirtualmachinenetworksettings:
TheBuildServerVMisconfiguredwithsixNetworkAdapters(1to6).InthiscustomizedBuildServersetup,onlytwoNetworkAdapter1-2willbeused.
a.ClickonEditVirtualMachineSettings.
b.MapeachNetworkAdapterasfollows:
NetworkAdapter1-VMNet10,Checkbox“ConnectatPoweron”
NetworkAdapter2-VMNet11,Checkbox“ConnectatPoweron”
NetworkAdapter3-HostOnly,Uncheckbox“ConnectatPoweron”
NetworkAdapter4-HostOnly,Uncheckbox“ConnectatPoweron”
NetworkAdapter5-HostOnly,Uncheckbox“ConnectatPoweron”
NetworkAdapter6-HostOnly,Uncheckbox“ConnectatPoweron”
25SetVirtualNetworkAdaptertoVMnet10
26SetvirtualnetworkadaptertoVMnet11
27FinalVMNetworkSettings
76.
]PoweronandtestBuildServervirtualmachine.
28BuildServerPower-on
c.TheBuildServerhasastaticIPaddressof192.168.254.20.CheckLinuxvirtualmachinenetworkandbuildnetworkconnectionsforthefollowingIPs.
ping192.168.254.20
ping192.168.252.252
9:
UploadVxRailv4.0.100softwareupdateimagetoBuildServer
TheBuildServerisaLinux-basedvirtualmachineaccessiblebywebbrowser.ThewebinterfaceisusedtouploadtheVxRailsoftwareimagestotheBuildServer.Thesoftwarethatwillbeloadedintotheappliancesisallbundledasonepackage.Thepartnumberofthispackageis992-720-600.LoadtheImagebundleintothebuildserverforprovisionanappliancewithfollowingsteps.
]LaunchaBuildServerbrowsertohttp:
//192.168.254.20andenablesystemconfiguration
29EnableBuildServerSystemConfiguration
12.
]UploadthegoldenimagetothebuildserverVM.
d.Fromtheconfigurationinterface,click“Clicktouploadgoldenimage”
30Uploadupgradepackage
e.Browsetothegoldenimagepackage,selectthefile,andwaitforimporttofinish
f.Aftertheimportcompletes,ClicktheBluebannerthatsays:
“Clicktoinstallpackage”
13.
]Uploadtheupgradepackage
g.Fromtheconfigurationinterface,click“Clicktouploadaupgradepackage”.Browsetothelocationwherethe“UpgradeImagePackage”islocated,selectthefile,andwaitforimporttofinish.
31FileSelection
32GoldenImageFileimport
33BuildServerreadyforusage
h.Oncetheuploadiscomplete,amessagewillpopupandthesystemisreadyforupgradingVxRailappliances.
VxRail_Nicias_Appliance_MBS_Cable_Gen2.doc
VxRailGen2Appliancev4.0.xSoftwareImageInstallationUsingMobileBuildServer.
Overview
ThisguideprovidesinstructionsonhowtouploadanewversionoftheVxRailsoftwareimagetoaVxRailGen2appliance.Thisprocessusesamobilebuildserver,whichisaportablevirtualmachinethatrunsonalaptopusingVMwareWorkstation(Windows)orVMwareFusion(Mac).ThebuildservercontainstheVxRailsoftwareimage,andthecodeinstructionstouploadtheimagetoeachnode.ThisprocessrequiresdedicatedandisolatednetworkconnectivitybetweenthebuildserverandeachoftheVxRailnodesintheappliance.
ThisProcedureisdestructiveandwillpermenantlyerasealldataontheappliance.PriortousingthisproceduretoupgradeanVxRailAppliance,Allcustomerdatamustbebackedupormigrationofftheappliance.
Thisprocessincludesthesemajormilestonesinordertoassureasuccessfulupgrade:
91.
]Alltheplanningandpreparationstepsarecompletedbeforeperformingtheupgrade.
92.
]Physicalnetworkconnectivityisestablishedbetweenthe‘uildServerandalloftheVxRailnodes.
93.
]ConnectivitytotheBuildServerwebinterfaceisestablished.
94.
]TheVxRailsoftwareupdatecompletessuccessfully.
95.
]TheupdatedVxRailapplianceisre-configured.
10:
Verifyallrequiredpre-requisite